What is NPSH? What is the difference between NPSH available and NPSH required?
Answer. NPSH is the margin of suction pressure above vapour pressure at the pump inlet; NPSHa is what the system gives, NPSHr is what the pump needs. Keep NPSHa ≥ NPSHr + margin.
Why. Inside the impeller eye the liquid accelerates and its pressure drops further. If it falls below vapour pressure, bubbles form and then collapse violently where pressure recovers — cavitation pits the impeller, makes noise and drops head.
How.
- NPSHa = (P_suction vessel − P_vapour)/ρg + static head − friction loss in suction line.
- NPSHr comes from the pump vendor curve (head drop of 3 % test) and rises with flow.
- Margin: typically 0.6–1 m or 10–30 % above NPSHr; more for hot or boiling liquids.
- Raise NPSHa: elevate the vessel, lower suction losses (bigger, shorter line, fewer fittings), cool the liquid, raise vessel pressure; or choose a low-NPSHr pump or inducer.
Only in industry. In refineries, reflux and boiler-feed pumps take suction from boiling liquid (NPSHa equals only static head minus losses), so drums are placed high on structures. A clogged suction strainer is the most common cause of sudden cavitation at site.
Why is a centrifugal pump started with the discharge valve closed (or slightly open)?
Answer. At zero flow a centrifugal pump draws minimum power, so starting against a closed discharge avoids motor overload; then the valve is opened slowly.
Why. Power = ρgQH/η. For radial centrifugal pumps power rises with flow, so the lowest starting current is at shut-off. Opening slowly also avoids water hammer and lets the line fill.
How.
- Prime the pump (casing full of liquid, vent air) and open the suction valve fully.
- Start the motor with discharge closed or just cracked.
- Open the discharge valve gradually while watching pressure and ammeter.
- Do not run long at shut-off: the liquid heats up and the pump can be damaged — a minimum-flow recirculation line protects it.
Only in industry. Axial-flow and some mixed-flow pumps are the exception: their power is highest at shut-off, so they are started with the valve open. Never throttle a pump on its suction valve — it causes cavitation.
Why do we prime a centrifugal pump but not a reciprocating pump?
Answer. A centrifugal pump develops head in proportion to fluid density; with air in the casing it cannot create enough suction to lift liquid. A positive-displacement pump physically displaces whatever is in the cylinder and can draw liquid up.
Why. Head H = u²/g roughly depends on impeller speed, not density, so the pressure rise ΔP = ρgH is about 800 times smaller for air than water — too little to pull liquid into the suction line.
How.
- Fill the casing and suction line with liquid through the priming funnel or by flooded suction.
- Vent air from the top of the casing.
- Self-priming pumps keep a liquid reserve in the casing; vacuum-assisted priming is used for large pumps.
How do you choose between a centrifugal and a positive-displacement pump?
Answer. Centrifugal for large flows of low-viscosity liquids at moderate head; positive displacement for high pressure, low flow, viscous liquids, accurate metering or where flow must be constant regardless of pressure.
Why. A centrifugal pump’s flow changes with system resistance and its efficiency collapses above ~200–500 cP. A PD pump delivers a fixed volume per stroke or revolution, so flow is almost independent of discharge pressure.
How.
- Centrifugal: water, hydrocarbons, cooling water, transfer pumps; controlled by throttling or speed.
- Reciprocating: high-pressure injection (chemicals, glycol), boiler feed for small units, hydrotest.
- Rotary (gear, screw, lobe): viscous oils, bitumen, polymers.
- Metering (diaphragm) pumps: chemical dosing — corrosion inhibitor, antifoam, caustic.
- PD pumps must have a relief valve on the discharge and are never started against a closed valve.
What are the pump affinity laws? Why are they useful?
Answer. For the same pump: Q ∝ N, H ∝ N², P ∝ N³ (and similarly with impeller diameter D for small trims).
Why. Similar velocity triangles: flow scales with tip speed, head with tip speed squared, power with their product. A 20 % speed cut halves power (0.8³ ≈ 0.51).
How.
- To reduce flow, a variable-frequency drive saves far more energy than throttling a valve.
- Impeller trimming gives a permanent reduction when a pump is oversized.
- Use them to predict the new duty point by scaling the pump curve and intersecting with the system curve.
Only in industry. Energy audits in PSUs routinely find pumps running against half-closed discharge valves; replacing throttling with a VFD or a trimmed impeller is a quick payback project.
What happens when two identical centrifugal pumps are run in parallel and in series?
Answer. Parallel: heads equal, flows add (double flow at the same head). Series: flows equal, heads add. The actual gain depends on the system curve.
Why. In a friction-dominated system, doubling flow needs much more head, so two pumps in parallel give much less than double flow; series operation helps more when head is needed.
How.
- Draw the combined pump curve (add flows horizontally for parallel, heads vertically for series).
- The operating point is where it meets the system curve.
- For parallel pumps, check each runs within its preferred operating region; non-return valves prevent backflow.
What is water hammer? How is it prevented?
Answer. A pressure surge when moving liquid is stopped suddenly (fast valve closure, pump trip); ΔP = ρaΔv can be tens of bar.
Why. The kinetic energy of the liquid column converts into elastic compression; the pressure wave travels at the speed of sound in the liquid–pipe system (~1000–1400 m/s) and reflects back and forth.
How.
- Close valves slowly (longer than the wave round-trip time 2L/a).
- Use surge vessels or accumulators, surge relief valves, and non-slam check valves.
- Keep velocities moderate; drain condensate from steam lines (steam hammer is caused by slugs of water).
Only in industry. Steam-line hammer during start-up is a classic plant problem: warm up lines slowly with drains open. Surge vessels are standard on long crude and product pipelines.
What is Reynolds number and why is it so important?
Answer. Re = ρvD/μ, the ratio of inertial to viscous forces. Below ~2100 flow in a pipe is laminar, above ~4000 turbulent.
Why. It decides the flow pattern and therefore friction, heat-transfer and mass-transfer coefficients. Two flows with the same Re (and geometry) behave alike — the basis of scale-up and model testing.
How.
- Laminar: f = 16/Re (Fanning), parabolic profile, poor mixing.
- Turbulent: f from the Moody chart or Colebrook equation, depends on roughness.
- Heat transfer: Nu = 0.023Re^0.8Pr^0.33 in turbulent flow.
How do you size a process pipeline?
Answer. Choose a diameter that keeps velocity and pressure drop within accepted limits, then check against economics, erosion and noise.
Why. A small pipe is cheap but needs more pumping energy and may erode; a large pipe costs more steel. The economic diameter balances capital and running cost.
How.
- Typical velocities: liquids 1–3 m/s (pump suction 0.5–1.5 m/s), gases 10–30 m/s, steam 20–40 m/s.
- Pressure-drop guidelines: e.g. 0.2–0.5 bar/100 m for liquid discharge lines.
- Compute ΔP with Darcy–Weisbach (f from Moody), add fittings as equivalent lengths.
- Pick the next standard pipe size (schedule from pressure and corrosion allowance).
Only in industry. Two-phase lines (flare, reboiler return) and slurry lines need special checks: slug flow, erosion velocity (API RP 14E, v_e = C/√ρ) and minimum velocity to avoid settling.
Gate valve, globe valve, ball valve, butterfly valve — where is each used?
Answer. Gate and ball valves for isolation (full open/closed); globe valves for throttling; butterfly for large low-pressure lines; check valves to prevent backflow.
Why. Gate and ball valves give a straight, low-loss path when open but control badly when partly open (erosion, vibration). A globe valve’s plug and seat give fine, stable throttling at the cost of higher pressure drop.
How.
- Gate: isolation on process and utility lines.
- Globe: bypass and throttling, manual flow control.
- Ball/plug: quick quarter-turn isolation, also for slurries (full bore).
- Butterfly: cooling water, large ducts; also as control valves.
- Check: swing, lift, dual-plate; on pump discharge to stop reverse rotation.
How is flow measured in a plant? Compare orifice, venturi, rotameter, magnetic and Coriolis meters.
Answer. Orifice and venturi infer flow from ΔP (Q ∝ √ΔP); rotameters by float position; magnetic meters from induced voltage in conducting liquids; Coriolis meters measure mass flow directly from tube twist.
Why. Bernoulli: accelerating fluid through a restriction lowers pressure; the drop gives velocity. Coriolis force on a vibrating tube is proportional to mass flow, independent of density and viscosity.
How.
- Orifice: cheap, high permanent loss, needs straight run (10–30 D upstream), range ~3:1.
- Venturi: low loss, expensive, used for large water lines.
- Magnetic: no obstruction, liquids with conductivity >5 µS/cm, slurries.
- Coriolis: custody transfer of products, high accuracy (0.1 %).
- Vortex, ultrasonic and turbine meters for steam, gas and clean liquids.
Only in industry. Custody transfer of crude and products to tankers and pipelines uses metering skids with prover loops; a 0.1 % error on a big refinery is crores per year.
What is the difference between a compressor, a blower and a fan?
Answer. They are classified by pressure ratio: fans up to ~1.1, blowers ~1.1–1.2, compressors above ~1.2.
Why. At low ratios gas behaves almost incompressibly; above ~1.2, compression heating and density change dominate and stages, intercoolers and surge control become necessary.
How.
- Reciprocating compressors: high ratio, low flow (hydrogen make-up).
- Centrifugal: large flows (recycle gas, refrigeration, air), need anti-surge control.
- Screw: medium flows, instrument air.
- Intercooling between stages approaches isothermal compression and saves power.
Only in industry. Centrifugal compressor trips from surge are a common start-up event; the anti-surge recycle valve is fast and set to fail open.
What are the detailed types of pumps used in a plant?
Answer. Dynamic: centrifugal (end-suction, split-case, vertical in-line, multistage, vertical turbine/sump), axial and mixed flow. Positive displacement: reciprocating (piston, plunger, diaphragm/metering), rotary (gear, screw, lobe, vane, progressive cavity).
Why. Duty decides type: high flow and moderate head → centrifugal; high pressure, low flow or viscous → positive displacement.
How.
- API 610 centrifugal pumps in refinery process service.
- Multistage centrifugal for boiler feed water.
- Screw pumps for heavy oils; gear pumps for lube oil.
- Diaphragm metering pumps for chemical dosing.
- Vertical turbine pumps for cooling-water sumps and river intakes.
How do you start a centrifugal pump from standby? Give the procedure.
Answer. Check, prime, open suction, start against a closed (or cracked) discharge, then open the discharge slowly while watching pressure and current.
Why. This protects the motor from overload, avoids cavitation and dry running, and prevents water hammer.
How.
- Pre-checks: permit closed, coupling guard fitted, lube oil level, seal flush/quench on, cooling water to bearings, motor isolator in “on”.
- Open suction valve fully; vent casing until liquid comes out (prime).
- Ensure discharge valve closed or cracked; minimum-flow line open if provided.
- Start; check discharge pressure builds to shut-off pressure and ammeter reading falls after starting peak.
- Open discharge gradually; check flow, vibration, noise, leakage, bearing temperature.
Only in industry. Never run a pump with suction closed — it overheats in minutes and the seal fails. Many incidents start with a pump started on the wrong line-up.
How do you change over from running pump A to standby pump B?
Answer. Prepare and start B, open its discharge slowly while throttling A’s discharge to keep flow steady, stop A, then close A’s discharge and keep A as standby or isolate it.
Why. Flow to the process must not be interrupted or doubled suddenly.
How.
- Check B ready (line-up, lube, seal, vent).
- Start B against closed discharge; confirm pressure.
- Open B discharge while closing A discharge gradually.
- Stop A; check NRV holds (A does not spin backward).
- Update log book and DCS running indication.
How do you safely take a running pump out for maintenance and connect the standby?
Answer. Change over to standby, stop the pump, isolate electrically and mechanically (discharge then suction valves, plus blinds if needed), drain, depressurise, flush or purge, verify zero energy, and hand over under a permit.
Why. Energy and hazardous fluid trapped in a pump can injure maintenance staff.
How.
- Run standby first (see changeover).
- Stop the pump; switch off and rack out / lock the breaker (LOTO).
- Close discharge, then suction valves; close seal flush and cooling.
- Drain to closed drain; vent to flare if volatile; flush with water or steam if toxic.
- Check pressure gauge zero and bleed; gas test; issue cold-work permit.
Only in industry. Suction side of a pump is often rated lower than discharge: always close the discharge valve first so the casing does not see discharge pressure through a passing NRV.
If you are confused whether pump A or pump B is running, how do you find out?
Answer. Check the ammeter/MCC indication and DCS status, feel and listen for vibration and noise, check discharge pressure gauges, coupling rotation and bearing temperature, and discharge valve positions.
Why. Both pumps look alike; operating the wrong one (e.g. stopping the running pump) can trip the unit.
How.
- Local panel or MCC shows running lamp and current.
- Running pump has discharge pressure at operating value and its discharge valve open.
- Coupling area is warm and visibly turning (do not touch rotating parts).
- Confirm with the panel operator before acting.
Why are daily readings of ampere, pressure and temperature taken for pumps and motors?
Answer. To detect problems early: a change in current, pressure, vibration or temperature shows wear, blockage, cavitation or process change before failure.
Why. Motor current reflects load (flow and head); falling discharge pressure means wear or suction problems; rising bearing temperature means lubrication trouble.
How.
- Log sheet each shift: suction and discharge pressure, motor current, bearing temperature, vibration, seal leakage, lube oil level, running hours.
- Compare with normal values; report deviations.
- Trend data in DCS or condition-monitoring systems.
Only in industry. The log sheet also proves which pump ran for how long — standby pumps are changed over regularly so both stay healthy.
What is multistage in a pump or compressor? Why is it used?
Answer. Several impellers (stages) in series on one shaft; each adds head, so the total head is roughly the sum.
Why. One impeller can only add limited head (tip speed limits); stages reach high pressure — e.g. boiler feed water at 100+ bar — with good efficiency.
How.
- Pumps: ring-section or barrel-type multistage pumps; balance drum handles axial thrust.
- Compressors: stages with intercoolers reduce power and keep temperature within limits.
- Each stage’s pressure ratio is kept moderate for stability.
What is the head of a pump? Why is it expressed in metres and not bar?
Answer. Head is the energy given per unit weight of liquid, expressed as a height of liquid column (m). It is independent of density, so a pump gives the same head for water or oil; the pressure rise ΔP = ρgH depends on density.
Why. Centrifugal pumps impart a velocity-based energy that depends on speed and impeller size, not on fluid density.
How.
- ΔP (bar) = ρ (kg/m³) × 9.81 × H (m)/10⁵.
- Total head = static head + pressure head difference + friction losses.
- Shut-off head is the head at zero flow.
What are the types of compressors and where is each used?
Answer. Positive displacement: reciprocating (high pressure, low flow — hydrogen make-up), screw (instrument/plant air, refrigeration), lobe/roots (low-pressure blowers). Dynamic: centrifugal (large gas flows — recycle gas, ammonia syngas, FCC wet gas) and axial (very large air flows — FCC air blower, gas turbines).
Why. Flow, pressure ratio, gas molecular weight and reliability decide the type.
How.
- Reciprocating: valves, pistons, packing; pulsation dampeners; usually with spare.
- Centrifugal: anti-surge control, dry gas seals, high reliability for single-train plants.
- Screw: oil-flooded or oil-free; simple and compact.
How is a reciprocating compressor started?
Answer. With lube oil and cooling water established, suction and discharge lined up and the unloaders open (unloaded start), the motor is started; the compressor is then loaded in steps (25–50–75–100 %).
Why. Starting loaded would demand very high torque from the motor and stress the machine.
How.
- Check KO drum level low, drains closed, frame oil and cylinder lubrication on.
- Bar the machine over by hand before first start after maintenance.
- Start unloaded, check vibration, temperatures, pressures; load in steps.
- Monitor valve temperatures — a hot valve indicates a broken valve.
What are dry gas seals in centrifugal compressors?
Answer. Non-contacting mechanical seals in which a thin film of filtered gas separates rotating and stationary faces; they replaced oil-film seals in most modern compressors.
Why. They leak very little process gas, need no seal-oil system and have low friction.
How.
- Clean, dry seal gas is supplied by a filtration panel; primary leakage goes to flare.
- Separation gas (nitrogen or air) keeps bearing oil away from the seals.
- Liquid or dirt in seal gas destroys seals — keep seal gas above its dew point.
What is the difference between a steam turbine and a gas turbine?
Answer. A steam turbine expands steam produced in a boiler; a gas turbine compresses air, burns fuel in it and expands the hot gas in the turbine (Brayton cycle), all in one machine.
Why. Gas turbines start quickly and are compact; steam turbines use heat from any fuel or waste heat and can extract process steam.
How.
- Gas turbines drive generators and pipeline compressors (GAIL compressor stations).
- Exhaust heat recovered in HRSGs to make steam (combined cycle / cogeneration).
- Gas turbine output falls in hot weather because air density drops.
What is a balance line in a pump?
Answer. In multistage centrifugal pumps, a balance line returns leakage from the balance drum or disc chamber to the pump suction, so the pressure behind the balance device stays near suction pressure and the axial thrust is balanced. (In tank systems, a vapour balance line connects tanks or tankers to exchange vapour during transfer.)
Why. Impellers create a large axial force towards suction; the balance drum produces an opposing force only if the chamber behind it is vented to suction.
How.
- A blocked balance line causes high thrust, bearing failure and rubbing.
- Rising balance-line flow or temperature indicates wear of the balance drum clearance.
- For volatile liquids, vent lines on suction vessels also balance pressure to keep NPSH steady.
What is the minimum flow (minimum continuous flow) of a centrifugal pump and how is it protected?
Answer. The lowest flow at which a centrifugal pump can run continuously without overheating, vibration or internal recirculation damage; it is protected by a minimum-flow recirculation line (with orifice, control valve or automatic recirculation valve) back to the suction vessel.
Why. At low flow almost all motor power turns into heat in a small volume of liquid, and flow separates inside the impeller, causing vibration and cavitation-like damage.
How.
- Vendor gives the minimum continuous stable flow (often 20–40 % of best efficiency flow).
- Min-flow line returns to the suction drum (not directly to the suction pipe, which would heat up).
- Automatic recirculation valves on boiler feed pumps open when forward flow falls.
Which pump would you choose for which service? Give a quick guide.
Answer. Clean liquid, high flow, moderate head → centrifugal; very high head → multistage centrifugal; small flow at high pressure or precise dosing → reciprocating/metering pump; viscous oils → gear, screw or progressive-cavity; slurry → slurry centrifugal or diaphragm; deep sump or river intake → vertical turbine; corrosive/toxic, zero leakage → magnetic-drive or canned pump.
Why. Each pump type has a best range of flow, head, viscosity and solids; using the wrong one wastes energy or fails quickly.
How.
- Plot required flow and head; check viscosity, NPSH available, solids and temperature.
- Check vendor curves and API 610/674/675 standards for refinery service.
- Always provide a standby for critical services.
Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.