Short answer: A pressure surge when moving liquid is stopped suddenly (fast valve closure, pump trip); ΔP = ρaΔv can be tens of bar.
Why
The kinetic energy of the liquid column converts into elastic compression; the pressure wave travels at the speed of sound in the liquid–pipe system (~1000–1400 m/s) and reflects back and forth.
How
- Close valves slowly (longer than the wave round-trip time 2L/a).
- Use surge vessels or accumulators, surge relief valves, and non-slam check valves.
- Keep velocities moderate; drain condensate from steam lines (steam hammer is caused by slugs of water).
What you learn only in industry
Steam-line hammer during start-up is a classic plant problem: warm up lines slowly with drains open. Surge vessels are standard on long crude and product pipelines.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NPCIL. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
What is water hammer? How is it prevented?
A pressure surge when moving liquid is stopped suddenly (fast valve closure, pump trip); ΔP = ρaΔv can be tens of bar. Why: The kinetic energy of the liquid column converts into elastic compression; the pressure wave travels at the speed of sound in the liquid–pipe system (~1000–1400 m/s) and reflects back and forth.
Related questions
- What is NPSH? What is the difference between NPSH available and NPSH required?
- Why is a centrifugal pump started with the discharge valve closed (or slightly open)?
- Why do we prime a centrifugal pump but not a reciprocating pump?
- How do you choose between a centrifugal and a positive-displacement pump?
- What are the pump affinity laws? Why are they useful?
- What happens when two identical centrifugal pumps are run in parallel and in series?