Short answer: Centrifugal for large flows of low-viscosity liquids at moderate head; positive displacement for high pressure, low flow, viscous liquids, accurate metering or where flow must be constant regardless of pressure.
Why
A centrifugal pump’s flow changes with system resistance and its efficiency collapses above ~200–500 cP. A PD pump delivers a fixed volume per stroke or revolution, so flow is almost independent of discharge pressure.
How
- Centrifugal: water, hydrocarbons, cooling water, transfer pumps; controlled by throttling or speed.
- Reciprocating: high-pressure injection (chemicals, glycol), boiler feed for small units, hydrotest.
- Rotary (gear, screw, lobe): viscous oils, bitumen, polymers.
- Metering (diaphragm) pumps: chemical dosing — corrosion inhibitor, antifoam, caustic.
- PD pumps must have a relief valve on the discharge and are never started against a closed valve.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
How do you choose between a centrifugal and a positive-displacement pump?
Centrifugal for large flows of low-viscosity liquids at moderate head; positive displacement for high pressure, low flow, viscous liquids, accurate metering or where flow must be constant regardless of pressure. Why: A centrifugal pump’s flow changes with system resistance and its efficiency collapses above ~200–500 cP. A PD pump delivers a fixed volume per stroke or revolution, so flow is almost independent of discharge pressure.
Related questions
- What is NPSH? What is the difference between NPSH available and NPSH required?
- Why is a centrifugal pump started with the discharge valve closed (or slightly open)?
- Why do we prime a centrifugal pump but not a reciprocating pump?
- What are the pump affinity laws? Why are they useful?
- What happens when two identical centrifugal pumps are run in parallel and in series?
- What is water hammer? How is it prevented?