Short answer: With lube oil and cooling water established, suction and discharge lined up and the unloaders open (unloaded start), the motor is started; the compressor is then loaded in steps (25–50–75–100 %).
Why
Starting loaded would demand very high torque from the motor and stress the machine.
How
- Check KO drum level low, drains closed, frame oil and cylinder lubrication on.
- Bar the machine over by hand before first start after maintenance.
- Start unloaded, check vibration, temperatures, pressures; load in steps.
- Monitor valve temperatures — a hot valve indicates a broken valve.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
How is a reciprocating compressor started?
With lube oil and cooling water established, suction and discharge lined up and the unloaders open (unloaded start), the motor is started; the compressor is then loaded in steps (25–50–75–100 %). Why: Starting loaded would demand very high torque from the motor and stress the machine.
Related questions
- What is NPSH? What is the difference between NPSH available and NPSH required?
- Why is a centrifugal pump started with the discharge valve closed (or slightly open)?
- Why do we prime a centrifugal pump but not a reciprocating pump?
- How do you choose between a centrifugal and a positive-displacement pump?
- What are the pump affinity laws? Why are they useful?
- What happens when two identical centrifugal pumps are run in parallel and in series?