Short answer: Head is the energy given per unit weight of liquid, expressed as a height of liquid column (m). It is independent of density, so a pump gives the same head for water or oil; the pressure rise ΔP = ρgH depends on density.

Why

Centrifugal pumps impart a velocity-based energy that depends on speed and impeller size, not on fluid density.

How

  1. ΔP (bar) = ρ (kg/m³) × 9.81 × H (m)/10⁵.
  2. Total head = static head + pressure head difference + friction losses.
  3. Shut-off head is the head at zero flow.

Likely focus at

IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.

Frequently asked questions

What is the head of a pump? Why is it expressed in metres and not bar?

Head is the energy given per unit weight of liquid, expressed as a height of liquid column (m). It is independent of density, so a pump gives the same head for water or oil; the pressure rise ΔP = ρgH depends on density. Why: Centrifugal pumps impart a velocity-based energy that depends on speed and impeller size, not on fluid density.