IITIAN1997 STUDIO

How do you change over from running pump A to standby pump B?

Pumps, piping & fluid flow · interview question with WHY and HOW

Ask your own question →

Short answer: Prepare and start B, open its discharge slowly while throttling A’s discharge to keep flow steady, stop A, then close A’s discharge and keep A as standby or isolate it.

Why

Flow to the process must not be interrupted or doubled suddenly.

How

  1. Check B ready (line-up, lube, seal, vent).
  2. Start B against closed discharge; confirm pressure.
  3. Open B discharge while closing A discharge gradually.
  4. Stop A; check NRV holds (A does not spin backward).
  5. Update log book and DCS running indication.

Likely focus at

IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.

Frequently asked questions

How do you change over from running pump A to standby pump B?

Prepare and start B, open its discharge slowly while throttling A’s discharge to keep flow steady, stop A, then close A’s discharge and keep A as standby or isolate it. Why: Flow to the process must not be interrupted or doubled suddenly.

Related questions

Ask your own question →