Short answer: Check, prime, open suction, start against a closed (or cracked) discharge, then open the discharge slowly while watching pressure and current.

Why

This protects the motor from overload, avoids cavitation and dry running, and prevents water hammer.

How

  1. Pre-checks: permit closed, coupling guard fitted, lube oil level, seal flush/quench on, cooling water to bearings, motor isolator in “on”.
  2. Open suction valve fully; vent casing until liquid comes out (prime).
  3. Ensure discharge valve closed or cracked; minimum-flow line open if provided.
  4. Start; check discharge pressure builds to shut-off pressure and ammeter reading falls after starting peak.
  5. Open discharge gradually; check flow, vibration, noise, leakage, bearing temperature.

What you learn only in industry

Never run a pump with suction closed — it overheats in minutes and the seal fails. Many incidents start with a pump started on the wrong line-up.

Likely focus at

IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.

Frequently asked questions

How do you start a centrifugal pump from standby? Give the procedure.

Check, prime, open suction, start against a closed (or cracked) discharge, then open the discharge slowly while watching pressure and current. Why: This protects the motor from overload, avoids cavitation and dry running, and prevents water hammer.

Related questions

Ask your own question →