Describe the flow of crude oil through a refinery.
Answer. Crude is desalted, heated and split in the atmospheric unit; residue goes to vacuum distillation; cuts are upgraded by cracking (FCC, hydrocracking, coking), reforming and treating, then blended into products.
Why. Crude contains everything from gas to asphalt; markets want mostly light, clean fuels, so primary distillation is followed by conversion and treating.
How.
- Primary: desalter → preheat train → furnace → atmospheric column (gas, naphtha, kerosene, diesel, residue) → vacuum unit.
- Secondary: FCC/hydrocracker (VGO → gasoline/diesel), delayed coker (residue → light products + coke), catalytic reformer (naphtha → high-octane reformate + H₂), isomerisation.
- Treating: hydrotreaters remove S, N; Merox for kerosene/LPG; SRU recovers sulphur.
- Blending to BS-VI specifications.
Why is crude oil desalted? How does a desalter work?
Answer. To remove salts (mostly NaCl, MgCl₂, CaCl₂) and water that would hydrolyse to HCl and corrode the overhead, and foul and poison downstream units.
Why. MgCl₂ and CaCl₂ hydrolyse above ~120 °C to HCl, which condenses with water in the column overhead and attacks steel.
How.
- Mix crude with 3–7 % wash water through a mixing valve.
- Electric field (AC, ~15–25 kV) coalesces droplets, which settle as brine.
- Demulsifier chemicals help; temperature ~120–150 °C lowers viscosity.
- Target outlet salt < ~1–3 PTB.
Only in industry. Overhead corrosion is controlled together with neutralising amines, filming inhibitors and caustic injection; chloride in overhead water is tracked daily.
How does an FCC unit work? Why is the catalyst regenerated?
Answer. Hot zeolite catalyst meets gas-oil feed in a riser and cracks it in seconds; spent catalyst, coated with coke, is burnt in a fluidised regenerator, and the hot catalyst returns to supply the heat of cracking.
Why. Cracking deposits coke that blocks active sites; burning it restores activity and provides the endothermic cracking heat — the unit is heat-balanced.
How.
- Riser outlet ~500–540 °C; regenerator ~680–730 °C.
- Cyclones separate catalyst from vapours; stripper removes hydrocarbons with steam.
- Products: LPG (propylene), gasoline, LCO, slurry.
- Catalyst-to-oil ratio ~5–8.
Only in industry. Afterburn in the regenerator dilute phase, catalyst losses through cyclones and slide-valve control are daily FCC issues.
What is catalytic reforming? What is the role of hydrogen there?
Answer. Converts low-octane naphtha into high-octane reformate (aromatics) over Pt–Re or Pt–Sn catalyst, producing hydrogen as a by-product.
Why. Dehydrogenation of naphthenes and dehydrocyclisation of paraffins create aromatics with high octane; the reactions are endothermic, so interheaters are used.
How.
- Feed hydrotreated to remove S and N (catalyst poisons).
- Hydrogen recycle suppresses coking; CCR units regenerate catalyst continuously.
- Reformer hydrogen supplies hydrotreaters.
Why is hydrotreating needed? What reactions occur?
Answer. To remove sulphur, nitrogen, oxygen and metals from fuels by reaction with hydrogen over Co-Mo or Ni-Mo catalysts, meeting BS-VI (10 ppm S) and protecting downstream catalysts.
Why. Sulphur forms SO₂ in engines and poisons catalysts; hydrogenation converts it to H₂S, which is easily removed.
How.
- Reactions: R-SH + H₂ → RH + H₂S; olefin saturation; denitrogenation to NH₃.
- Conditions 300–400 °C, 30–150 bar.
- H₂S removed in amine units, converted to sulphur in the SRU (Claus).
What is octane number and cetane number?
Answer. Octane measures resistance of petrol to knocking (iso-octane = 100, n-heptane = 0); cetane measures ignition quality of diesel (n-hexadecane = 100).
Why. Petrol engines need fuel that does not self-ignite under compression; diesel engines need fuel that self-ignites quickly.
How.
- Branched paraffins and aromatics raise octane; straight-chain paraffins raise cetane.
- Octane improved by reforming, isomerisation, alkylation, FCC, ethanol blending.
- RON and MON are measured in a CFR engine.
What is the Claus process?
Answer. Converts H₂S from amine units into elemental sulphur: one-third is burnt to SO₂, which reacts with the remaining H₂S over alumina catalyst: 2H₂S + SO₂ → 3S + 2H₂O.
Why. H₂S cannot be flared (SO₂ emissions) and is toxic; sulphur is a saleable by-product.
How.
- Thermal stage (furnace ~1000–1300 °C), then 2–3 catalytic converters with condensers.
- Recovery ~95–97 %; tail-gas treating (SCOT) lifts it above 99.5 %.
- Keep H₂S/SO₂ ratio at 2 using a tail-gas analyser.
What is delayed coking? Why "delayed"?
Answer. Thermal cracking of vacuum residue: feed is heated quickly in a furnace and the cracking and coking happen later in large drums, producing gas, naphtha, gas oils and petroleum coke.
Why. High velocity and short residence in the furnace tubes delay coking until the oil reaches the drums, so tubes do not plug.
How.
- Drums fill over ~16–24 h, then switch; the full drum is steamed, cooled and decoked with high-pressure water jets.
- Coker products need hydrotreating.
Only in industry. Drum switching and hydraulic decoking are among the most hazardous routine refinery operations; strict procedures and interlocks apply.
How is ethylene produced? Describe a naphtha or gas cracker.
Answer. Steam cracking: ethane, propane or naphtha mixed with steam is cracked at ~800–850 °C for a fraction of a second, quenched, compressed and separated cryogenically.
Why. High temperature breaks C–C and C–H bonds into olefins; short residence and low hydrocarbon partial pressure (steam dilution) maximise ethylene and limit coke.
How.
- Transfer-line exchangers quench and make HP steam.
- Cracked gas compressor, caustic wash for CO₂/H₂S, drying.
- Cold box, demethaniser, deethaniser, C₂ splitter, C₃ splitter.
- Furnaces decoked periodically with steam–air.
Only in industry. BCPL in Assam cracks natural gas and naphtha to make HDPE, LLDPE and PP — a direct local example.
What is the ASTM distillation curve and what does TBP tell you?
Answer. Boiling-range tests: ASTM D86 boils a sample in a simple flask (product quality); TBP uses many stages and reflux to give true boiling points (crude assay).
Why. Products are mixtures; their boiling range decides volatility, cold-flow behaviour and how crude will split into products.
How.
- TBP curve of crude gives yield of each cut.
- Cut points set naphtha, kerosene and diesel draws.
- Flash point, pour point and viscosity tests complete product specs.
What is the difference between API gravity and specific gravity?
Answer. °API = 141.5/SG − 131.5 at 60 °F. Higher API means lighter crude; water is 10 °API.
Why. Light crudes (API > 31) give more high-value distillates; heavy crudes need more conversion capacity.
How.
- Brent ~38 °API, Arab Light ~33, heavy crudes < 22.
- Sour crude: high sulphur; sweet: low sulphur.
What is a tank farm? Why floating roofs?
Answer. Storage area for crude, intermediates and products. Volatile liquids (crude, petrol) are stored in floating-roof tanks to eliminate the vapour space and evaporation losses.
Why. Fixed-roof tanks breathe: vapour is expelled when filling or warming, losing product and creating fire hazard.
How.
- Fixed roof with nitrogen blanketing for low-volatility or sensitive products.
- Bunds (dykes) hold 110 % of the largest tank.
- Fire protection: foam pourers, rim-seal detection, water sprinklers.
Only in industry. Buncefield (UK, 2005) began with tank overfilling and the IOCL Jaipur fire (2009) with a leak during a valve line-up; since then independent overfill protection and remotely operated shut-off valves on tank outlets are expected.
What is LPG made of? Why is mercaptan added?
Answer. Mainly propane and butane. An odorant (ethyl mercaptan) is added so leaks can be smelt, because LPG itself is odourless.
Why. LPG is heavier than air and collects in low places; early detection by smell prevents explosions.
How.
- Stored under pressure as liquid in bullets or spheres.
- Merox treating removes natural mercaptans; odorant is added back in controlled amount for safety.
- Bottling plants check weight and leaks.
How are polymers like polyethylene and polypropylene produced commercially?
Answer. By catalytic polymerisation of ethylene or propylene in gas-phase fluidised beds, slurry loops or solution reactors, using Ziegler–Natta, chromium or metallocene catalysts.
Why. Catalysts allow low-pressure, controlled polymerisation with chosen density and molecular weight; hydrogen controls chain length; comonomers control density.
How.
- HDPE: slurry or gas phase; LLDPE: gas phase with butene/hexene; PP: gas or bulk loop.
- Heat removal is the key design constraint (very exothermic).
- Extruder pelletises the powder with additives.
What does MMTPA mean? Which unit does refinery capacity refer to?
Answer. Million metric tonnes per annum; a refinery’s capacity is the crude oil it can process in a year, i.e. the capacity of its crude distillation unit (CDU/AVU).
Why. All downstream units are sized relative to crude throughput.
How.
- 1 MMTPA ≈ 20 000 barrels per day (approx., depends on crude density).
- Secondary units are quoted in their own capacities (e.g. FCC in MMTPA of feed).
Why is sulphuric acid used in refineries?
Answer. Mainly as the catalyst in sulphuric-acid alkylation units, which combine isobutane with C₃–C₄ olefins to make alkylate (a clean, high-octane petrol component); also for pH control and regeneration of cation-exchange resins in water treatment.
Why. Strong acid promotes the carbocation reactions of alkylation at low temperature; alkylate has no aromatics, olefins or sulphur.
How.
- Acid strength is kept above ~88–90 %; spent acid is regenerated.
- Some refineries recover sulphur as sulphuric acid (wet sulphuric acid process) instead of elemental sulphur.
- Acid handling needs acid-resistant PPE and materials.
What are BIS, BS-VI and Euro norms?
Answer. BIS (Bureau of Indian Standards) publishes fuel specifications (e.g. IS 2796 petrol, IS 1460 diesel). Bharat Stage (BS) norms are India’s vehicle-emission standards modelled on Euro norms; BS-VI, nationwide from April 2020, limits fuel sulphur to 10 ppm, matching Euro VI.
Why. Low sulphur enables catalytic after-treatment in vehicles and cuts SO₂ and particulate emissions.
How.
- Refineries added hydrotreating and hydrogen capacity to meet BS-VI.
- India moved directly from BS-IV to BS-VI, skipping BS-V.
What is the future of the oil and gas industry?
Answer. Oil and gas will remain important for decades, especially in growing economies like India, but companies are shifting towards petrochemicals, natural gas, biofuels (ethanol, compressed biogas, SAF), green hydrogen, carbon capture and efficiency to meet net-zero goals.
Why. Transport is electrifying gradually, while demand for chemicals and plastics keeps growing and climate policies push lower emissions.
How.
- Refineries integrating petrochemicals (crude-to-chemicals).
- Indian PSUs have announced net-zero targets and green hydrogen, biofuel and renewable projects.
- Skills in process optimisation, energy efficiency and new energy will be valued.
How is the level or quantity in a storage tank measured?
Answer. By automatic tank gauging (radar, servo or float gauges) with temperature probes, checked by manual dip tape; volume from calibration (strapping) tables, corrected to 15 °C using density.
Why. Stock accounting and custody transfer need accurate quantities; overfilling must be prevented.
How.
- Manual dip with tape and bob through the dip hatch; water cut with water-finding paste.
- Calibration chart converts level to volume.
- Independent high-high level alarm/trip protects against overfill.
What is tank dewatering and why is it done?
Answer. Draining settled water from the bottom of crude and product tanks through the water-draw valve until oil appears.
Why. Water settles out of crude and products; it causes corrosion, upsets the crude unit and makes products off-spec.
How.
- Drain slowly under supervision; never leave a draining valve unattended.
- Drain to the oily-water sewer, watching for hydrocarbon carry-over.
- Watch for H₂S in sour crude tanks.
Only in industry. Unattended tank draining has caused major spills and fires — this is a classic “never leave the valve” rule.
What happens at a loading gantry / tank-truck filling station?
Answer. Products are loaded into tank trucks or wagons through loading arms with metered quantity, earthing and overfill protection, and sealed for dispatch.
Why. Loading is a major fire and spill risk because of vapours, static and human error.
How.
- Earthing relay must be connected before the pump starts (interlock).
- Bottom loading with vapour recovery preferred.
- Pre-set batch controller stops at the set quantity.
- Truck checks: valid licence, PESO permits, spark arrestor, no mobile phones.
Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.