Short answer: Draining settled water from the bottom of crude and product tanks through the water-draw valve until oil appears.
Why
Water settles out of crude and products; it causes corrosion, upsets the crude unit and makes products off-spec.
How
- Drain slowly under supervision; never leave a draining valve unattended.
- Drain to the oily-water sewer, watching for hydrocarbon carry-over.
- Watch for H₂S in sour crude tanks.
What you learn only in industry
Unattended tank draining has caused major spills and fires — this is a classic “never leave the valve” rule.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
What is tank dewatering and why is it done?
Draining settled water from the bottom of crude and product tanks through the water-draw valve until oil appears. Why: Water settles out of crude and products; it causes corrosion, upsets the crude unit and makes products off-spec.
Related questions
- Describe the flow of crude oil through a refinery.
- Why is crude oil desalted? How does a desalter work?
- How does an FCC unit work? Why is the catalyst regenerated?
- What is catalytic reforming? What is the role of hydrogen there?
- Why is hydrotreating needed? What reactions occur?
- What is octane number and cetane number?