Short answer: Hot zeolite catalyst meets gas-oil feed in a riser and cracks it in seconds; spent catalyst, coated with coke, is burnt in a fluidised regenerator, and the hot catalyst returns to supply the heat of cracking.
Why
Cracking deposits coke that blocks active sites; burning it restores activity and provides the endothermic cracking heat — the unit is heat-balanced.
How
- Riser outlet ~500–540 °C; regenerator ~680–730 °C.
- Cyclones separate catalyst from vapours; stripper removes hydrocarbons with steam.
- Products: LPG (propylene), gasoline, LCO, slurry.
- Catalyst-to-oil ratio ~5–8.
What you learn only in industry
Afterburn in the regenerator dilute phase, catalyst losses through cyclones and slide-valve control are daily FCC issues.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, EIL. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
How does an FCC unit work? Why is the catalyst regenerated?
Hot zeolite catalyst meets gas-oil feed in a riser and cracks it in seconds; spent catalyst, coated with coke, is burnt in a fluidised regenerator, and the hot catalyst returns to supply the heat of cracking. Why: Cracking deposits coke that blocks active sites; burning it restores activity and provides the endothermic cracking heat — the unit is heat-balanced.