Short answer: Fouling is the build-up of deposits (scale, coke, biological growth, corrosion products) on heat-transfer surfaces; it adds resistance R_f and lowers U and duty.
Why
1/U = 1/h_o + R_fo + wall + R_fi + 1/h_i: a deposit with low thermal conductivity adds a large resistance. It also narrows the flow area, raising pressure drop.
How
- Design: add fouling factors (e.g. 0.0002–0.0005 m²K/W) and 10–25 % extra area.
- Operation: keep velocity high, control cooling water chemistry (pH, inhibitors, biocides), use antifoulants in crude.
- Monitoring: track U from plant data over time.
- Cleaning: chemical cleaning, hydro-jetting, pigging; spare exchangers allow on-line cleaning.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NPCIL. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
What is fouling? How does it affect a heat exchanger and how is it controlled?
Fouling is the build-up of deposits (scale, coke, biological growth, corrosion products) on heat-transfer surfaces; it adds resistance R_f and lowers U and duty. Why: 1/U = 1/h_o + R_fo + wall + R_fi + 1/h_i: a deposit with low thermal conductivity adds a large resistance. It also narrows the flow area, raising pressure drop.
Related questions
- Why is counter-current flow preferred in heat exchangers?
- Which fluid goes on the tube side of a shell-and-tube exchanger, and why?
- What is the difference between fixed tube sheet, U-tube and floating-head exchangers?
- Why is steam used as a heating medium? Why saturated rather than superheated steam?
- What is a steam trap? Name the types.
- Explain the working of a fired heater (furnace) in a refinery.