Short answer: A loss of temperature control where heat generation (exponential in T) outruns heat removal (linear in T), so temperature and rate accelerate.
Why
Arrhenius: rate doubles every ~10 °C; cooling grows only with ΔT. Beyond a critical point (Semenov) there is no stable balance.
How
- Design: adequate cooling, small batch inventory, semi-batch addition of reagent.
- Controls: high-temperature interlocks to stop feed, emergency cooling, quench or kill agents.
- Relief: rupture discs and vent sizing for two-phase flow (DIERS).
- Know the onset temperature from calorimetry (DSC, ARC).
What you learn only in industry
Bhopal (MIC), Seveso and many fine-chemical accidents were runaways. HAZOP always asks: what if cooling fails or reagent is added too fast?
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, DRDO, NFL, RCF, BVFCL. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
What is a runaway reaction and how is it prevented?
A loss of temperature control where heat generation (exponential in T) outruns heat removal (linear in T), so temperature and rate accelerate. Why: Arrhenius: rate doubles every ~10 °C; cooling grows only with ΔT. Beyond a critical point (Semenov) there is no stable balance.
Related questions
- CSTR or PFR — which needs a smaller volume and why?
- What is a catalyst? Does it change equilibrium?
- What is residence time distribution and why is it measured?
- Why is ammonia synthesis carried out at high pressure and moderate temperature?
- What is the Thiele modulus and effectiveness factor?
- Batch or continuous process — how do you decide?