Short answer: A PCV continuously regulates pressure at a set point during normal operation (control function); a PSV stays shut and opens only in an emergency when pressure exceeds its set pressure (protection function).
Why
Control and protection must be independent: if the control loop fails, the relief device still protects the equipment.
How
- PCV: control valve driven by a pressure controller, or a self-acting regulator (e.g. nitrogen blanketing, fuel gas let-down).
- PSV: spring-loaded, set at or below design pressure, discharges to flare or atmosphere.
- Typical order: normal pressure < PCV set point < alarm < trip < PSV set pressure ≤ design pressure.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
What is a pressure control valve (PCV) and how is it different from a PSV?
A PCV continuously regulates pressure at a set point during normal operation (control function); a PSV stays shut and opens only in an emergency when pressure exceeds its set pressure (protection function). Why: Control and protection must be independent: if the control loop fails, the relief device still protects the equipment.
Related questions
- How do you know whether a gate valve, a globe valve or a butterfly valve is open or closed?
- What is an NRV (non-return valve)? Where is it fitted on a pump and why?
- Why is the discharge isolation (gate) valve placed after the NRV on a pump?
- What does “crack open” a valve mean?
- What are LO, LC, CSO, CSC (always-open and always-closed) valves?
- What is a pneumatic control valve? What do air-to-open and air-to-close mean?