Short answer: Generally the cold fluid is introduced first and the hot fluid gradually afterwards; on shutdown, the hot fluid is stopped first.
Why
Admitting hot fluid into an empty, cold exchanger causes thermal shock, uneven expansion, tube-to-tubesheet leaks and possibly vaporisation or hammer.
How
- Vent air and fill slowly; open cold-side inlet and outlet.
- Crack open the hot side; raise flow slowly to heat up at a controlled rate.
- Watch for leaks at flanges as temperature rises (hot bolting may be needed).
- Follow the plant procedure — for some services (e.g. steam heaters) specific sequences apply.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
In which order are hot and cold fluids introduced when starting a heat exchanger?
Generally the cold fluid is introduced first and the hot fluid gradually afterwards; on shutdown, the hot fluid is stopped first. Why: Admitting hot fluid into an empty, cold exchanger causes thermal shock, uneven expansion, tube-to-tubesheet leaks and possibly vaporisation or hammer.
Related questions
- Why is counter-current flow preferred in heat exchangers?
- Which fluid goes on the tube side of a shell-and-tube exchanger, and why?
- What is fouling? How does it affect a heat exchanger and how is it controlled?
- What is the difference between fixed tube sheet, U-tube and floating-head exchangers?
- Why is steam used as a heating medium? Why saturated rather than superheated steam?
- What is a steam trap? Name the types.