How do you detect a tube leak in a heat exchanger?

Heat exchangers, furnaces & steam · interview question with WHY and HOW

Ask your own question →

Short answer: By contamination of the lower-pressure fluid with the higher-pressure one: hydrocarbon in cooling water (oil sheen, LEL in cooling-tower air, rising COD), conductivity rise in condensate, colour or analysis change, or pressure equalisation.

Why

Flow always leaks from high pressure to low pressure side.

How

  1. Sample both streams; compare with normal.
  2. Isolate exchangers one by one in a bank to locate the leaking one.
  3. In shutdown: hydrotest shell side and watch tube ends; plug leaking tubes (keep within ~10 % plugging).

What you learn only in industry

Hydrocarbon leaking into cooling water can create flammable vapour at the cooling tower — LEL checks at the tower deck are routine.

Likely focus at

IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.

Frequently asked questions

How do you detect a tube leak in a heat exchanger?

By contamination of the lower-pressure fluid with the higher-pressure one: hydrocarbon in cooling water (oil sheen, LEL in cooling-tower air, rising COD), conductivity rise in condensate, colour or analysis change, or pressure equalisation. Why: Flow always leaks from high pressure to low pressure side.