Short answer: To collect and safely burn gases released by relief valves, depressurisation and start-up/shut-down, instead of venting toxic or flammable gas.
Why
Venting would create flammable clouds and toxic exposure; burning converts hydrocarbons to CO₂ and water at a safe height.
How
- Relief header → knock-out drum (removes liquid) → water seal drum (prevents flashback) → flare stack with pilots and steam for smokeless burning.
- Purge gas keeps air out of the header.
- Flare gas recovery compressors cut routine flaring.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
Why is a flare system needed in a refinery?
To collect and safely burn gases released by relief valves, depressurisation and start-up/shut-down, instead of venting toxic or flammable gas. Why: Venting would create flammable clouds and toxic exposure; burning converts hydrocarbons to CO₂ and water at a safe height.
Related questions
- What is HAZOP? Explain guide words with an example.
- What is the difference between a safety valve, a relief valve and a rupture disc?
- What is a permit-to-work system? Name the types of permits.
- What is LOTO (lock-out tag-out)?
- What are LEL and UEL? What is flash point and auto-ignition temperature?
- Explain the fire triangle and classes of fire. Which extinguisher for which fire?