Short answer: To collect and safely burn gases released by relief valves, depressurisation and start-up/shut-down, instead of venting toxic or flammable gas.

Why

Venting would create flammable clouds and toxic exposure; burning converts hydrocarbons to CO₂ and water at a safe height.

How

  1. Relief header → knock-out drum (removes liquid) → water seal drum (prevents flashback) → flare stack with pilots and steam for smokeless burning.
  2. Purge gas keeps air out of the header.
  3. Flare gas recovery compressors cut routine flaring.