Short answer: Safety valves pop fully open (gases, steam); relief valves open gradually in proportion to overpressure (liquids); rupture discs burst once at a set pressure and must be replaced.
Why
Compressible fluids need rapid full lift to discharge large volumes; liquids only need small flow, and pop action would chatter. Rupture discs are leak-tight, fast and handle corrosive or polymerising services.
How
- Set pressure ≤ MAWP; accumulation limits 10 % (single valve), 21 % (fire case).
- Blowdown: pressure drop before reseating (typically 5–10 %).
- Rupture disc upstream of a PSV protects it from corrosion; a pressure gauge between them detects leaks.
- Sizing per API 520/521 for the worst credible case (blocked outlet, fire, tube rupture, reflux failure).
What you learn only in industry
PSVs are removed and bench-tested on a schedule; the isolation valves under them are car-sealed open (CSO). Finding a closed block valve under a PSV is a serious audit finding.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, BARC, NPCIL, Heavy Water Board, DRDO, ISRO. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
What is the difference between a safety valve, a relief valve and a rupture disc?
Safety valves pop fully open (gases, steam); relief valves open gradually in proportion to overpressure (liquids); rupture discs burst once at a set pressure and must be replaced. Why: Compressible fluids need rapid full lift to discharge large volumes; liquids only need small flow, and pop action would chatter. Rupture discs are leak-tight, fast and handle corrosive or polymerising services.
Related questions
- What is HAZOP? Explain guide words with an example.
- What is a permit-to-work system? Name the types of permits.
- What is LOTO (lock-out tag-out)?
- What are LEL and UEL? What is flash point and auto-ignition temperature?
- Explain the fire triangle and classes of fire. Which extinguisher for which fire?
- What is a BLEVE? How is it prevented?