What is reflux and why is it needed in a distillation column?
Answer. Reflux is condensed overhead liquid returned to the top of the column; it provides the liquid that contacts rising vapour and makes the rectifying section work.
Why. Without downflowing liquid there is no counter-current contact above the feed, so heavy components cannot be washed out of the vapour. More reflux gives better separation but costs more reboiler and condenser duty.
How.
- Minimum reflux needs infinite stages; total reflux needs minimum stages (Fenske).
- Operating reflux is usually 1.1–1.5 × R_min.
- Increase reflux to improve top purity; check flooding and reboiler capacity.
Only in industry. Operators raise reflux when the top product goes off-spec, but too much reflux floods the column or overloads the reboiler — watch differential pressure across the column.
What is flooding in a distillation column? What are its signs and causes?
Answer. Flooding is when liquid cannot flow down because vapour flow is too high (or downcomers back up); liquid accumulates and the column fills.
Why. High vapour velocity entrains liquid upward and raises tray pressure drop, which raises liquid height in downcomers until they overflow onto the tray above.
How.
- Signs: sharp rise in column ΔP, drop in bottom level, loss of separation, liquid in the overhead.
- Causes: high feed or boil-up, foaming, damaged or plugged trays, high reflux.
- Fix: reduce boil-up or feed, add antifoam, inspect trays at turnaround.
- Design at 70–85 % of flooding velocity.
Only in industry. Panel operators watch column ΔP trends more than any analyser; a gamma scan during operation shows which trays are flooded or damaged without opening the column.
What are weeping and entrainment on trays?
Answer. Weeping: liquid leaks through tray holes at low vapour rate. Entrainment: liquid droplets are carried up to the tray above at high vapour rate.
Why. Vapour pressure through holes holds the liquid on the tray; too little vapour lets it drain; too much throws droplets up. Both reduce tray efficiency.
How.
- Valve trays give better turndown (less weeping) than sieve trays.
- Operating window lies between the weep line and the flood line.
- Bubble-cap trays handle very low liquid rates; packed columns suit low ΔP and corrosive service.
Why is vacuum distillation used for heavy residues?
Answer. To boil heavy fractions at lower temperatures (below ~380–400 °C) and avoid thermal cracking and coking.
Why. Boiling point falls with pressure. Atmospheric residue would need over 500 °C to vaporise its gas oils at 1 atm, where it would crack.
How.
- Column top at 50–100 mmHg absolute, made by steam ejectors or vacuum pumps.
- Steam stripping lowers hydrocarbon partial pressure further.
- Products: vacuum gas oils (FCC/hydrocracker feed), lube base stocks, vacuum residue (bitumen, coker feed).
Only in industry. Air leaks raise column pressure and cut gas-oil yield; leak testing and ejector steam pressure are routine checks.
What is an azeotrope? How do you separate one?
Answer. A mixture whose vapour and liquid have the same composition at some point, so ordinary distillation cannot cross it (e.g. ethanol–water at ~95.6 wt %).
Why. At the azeotrope the relative volatility is 1, so the equilibrium and operating lines meet.
How.
- Pressure-swing distillation when the azeotrope composition shifts with pressure.
- Extractive distillation with a solvent that changes relative volatility (ethylene glycol for ethanol).
- Azeotropic distillation with an entrainer (benzene, cyclohexane historically).
- Molecular sieves or pervaporation membranes for fuel-ethanol dehydration.
Only in industry. India’s ethanol-blending plants use molecular-sieve dehydration after distillation to reach 99.5 % ethanol.
How do you choose between a tray column and a packed column?
Answer. Packed columns for small diameters, low pressure drop (vacuum), corrosive or foaming systems; trays for large diameters, high liquid rates, fouling services and where side draws are needed.
Why. Packing gives more interfacial area per ΔP but is sensitive to liquid distribution; trays are robust, easy to inspect and handle wide load ranges.
How.
- Structured packing in vacuum columns and revamps for capacity.
- Random packing (Pall rings, saddles) in absorbers and strippers.
- Distributors and redistributors are critical in packed beds.
Why does an absorber operate at high pressure and low temperature, and a stripper at low pressure and high temperature?
Answer. Gas solubility rises with partial pressure and falls with temperature (Henry’s law), so absorption is favoured by high P and low T; stripping, the reverse.
Why. Equilibrium y* = mx; m = H/P falls with pressure and rises with temperature. A small m means the gas prefers the liquid.
How.
- Amine (MEA, MDEA) units absorb H₂S and CO₂ at ~30–40 °C and high pressure, regenerate at ~110–120 °C near atmospheric pressure.
- L/G ≈ 1.2–1.5 times minimum.
- Use the Kremser equation for stages with dilute systems.
Only in industry. Amine foaming (from hydrocarbons and degradation products) causes sudden carry-over; antifoam and carbon filtration of lean amine are standard.
What is the difference between adsorption and absorption? Explain PSA.
Answer. Absorption dissolves a gas into the bulk of a liquid; adsorption holds molecules on the surface of a porous solid. PSA adsorbs impurities at high pressure and releases them at low pressure.
Why. Adsorption capacity rises with partial pressure, so cycling pressure regenerates the bed in minutes without heating.
How.
- Hydrogen PSA units (4–12 beds) give 99.9+ % H₂ for hydrotreaters.
- Molecular sieves dry natural gas before cryogenic processing (TSA).
- Isotherms (Langmuir, Freundlich) decide bed size.
What is liquid–liquid extraction and where is it used?
Answer. Separation by transferring a solute from one liquid to an immiscible solvent in which it is more soluble.
Why. Useful when distillation is impossible or uneconomic: close boiling points, heat-sensitive materials, very dilute solutes, or metals in solution.
How.
- Aromatics extraction with sulfolane; lube oil extraction with furfural or NMP.
- PUREX: uranium and plutonium extracted from nitric acid into TBP/dodecane — the heart of nuclear reprocessing.
- Equipment: mixer–settlers, pulsed columns, centrifugal contactors.
Only in industry. Nuclear extraction uses pulsed columns and centrifugal contactors because they need no moving parts in radiation fields or very short contact times.
What is the McCabe–Thiele method and what are its assumptions?
Answer. A graphical method for the number of ideal stages in binary distillation using equilibrium and operating lines on an x–y diagram.
Why. With constant molar overflow (equal molar latent heats, no heat loss), liquid and vapour flows are constant in each section, so the operating lines are straight.
How.
- Rectifying line y = (R/(R+1))x + x_D/(R+1).
- q-line from the feed condition: slope q/(q − 1).
- Step off stages between equilibrium curve and operating lines; the step crossing the q-line is the feed stage.
What is a cooling tower? Explain range and approach.
Answer. It cools water mainly by evaporating a small part of it into air. Range = hot water − cold water temperature; approach = cold water − ambient wet-bulb temperature.
Why. Evaporation removes latent heat; the lowest possible water temperature is the wet bulb. A small approach needs a much bigger tower.
How.
- Evaporation ≈ 1 % of flow per ~6–7 °C range.
- Make-up = evaporation + drift + blowdown; blowdown = E/(COC − 1).
- Treat water for scale, corrosion and biological growth.
How does a membrane separate gases or salts? Give plant uses.
Answer. A selective barrier lets some species permeate faster under a pressure or concentration difference: RO passes water but not salt; polymer membranes pass H₂ or CO₂ faster than CH₄ or N₂.
Why. In dense membranes species dissolve and diffuse; permeability = solubility × diffusivity differs between species.
How.
- RO for boiler feed water and desalination (above osmotic pressure).
- H₂ recovery from purge gas in ammonia and refinery units.
- N₂ generators for blanketing.
- Watch concentration polarisation and fouling; pretreat feed.
Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.