What is the difference between design pressure, operating pressure and MAWP? What is a hydrotest?

Materials, corrosion & equipment · interview question with WHY and HOW

Ask your own question →

Short answer: Operating pressure is normal running pressure; design pressure is set above it (typically +10 % or +1–2 bar) for upsets; MAWP is the maximum pressure the built vessel can take at its coincident temperature. Hydrotest pressurises with water to ~1.3 × design (ASME VIII Div. 1) to prove strength and tightness.

Why

Margins cover upsets and relief valve accumulation; water stores little energy, so a hydrotest failure does not explode like a gas test.

How

  1. PSV set at or below MAWP.
  2. Hydrotest: vent air, hold pressure, inspect welds; test temperature above brittle-fracture limit.
  3. Pneumatic tests only when water is not allowed, with strict precautions.

Likely focus at

IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, BARC, NPCIL, Heavy Water Board, DRDO, ISRO. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.

Frequently asked questions

What is the difference between design pressure, operating pressure and MAWP? What is a hydrotest?

Operating pressure is normal running pressure; design pressure is set above it (typically +10 % or +1–2 bar) for upsets; MAWP is the maximum pressure the built vessel can take at its coincident temperature. Hydrotest pressurises with water to ~1.3 × design (ASME VIII Div. 1) to prove strength and tightness. Why: Margins cover upsets and relief valve accumulation; water stores little energy, so a hydrotest failure does not explode like a gas test.