Short answer: A variable-area flow meter: a float rises in a tapered tube until the drag force of the flow balances its weight; float height gives flow.
Why
The balance between gravity on the float and fluid drag only works when the tube is vertical with flow upward.
How
- Read at the float’s reading edge (usually the widest part).
- Calibrated for a specific fluid density; correct for other fluids.
- Used for purge flows, sample lines, small chemical dosing.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, NFL, RCF, BVFCL, NPCIL, Heavy Water Board. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
What is a rotameter and why must it be vertical?
A variable-area flow meter: a float rises in a tapered tube until the drag force of the flow balances its weight; float height gives flow. Why: The balance between gravity on the float and fluid drag only works when the tube is vertical with flow upward.
Related questions
- How does a Bourdon-tube pressure gauge work?
- What is the difference between a pressure gauge and a pressure transmitter?
- Why is a 4–20 mA signal used and not 0–20 mA?
- What is a DPT (differential pressure transmitter) and where is it used?
- What are the four basic process variables and how is each measured?
- What is a thermowell? Why is it used?