Short answer: By removing heat through a jacket, coil or external exchanger with a cascade loop (temperature master, coolant flow or temperature slave), with interlocks on high temperature.
Why
Heat release rises exponentially with temperature; the control loop must react faster than the reaction can run away.
How
- Cascade: reactor TIC → jacket inlet TIC or coolant FIC.
- Limit feed addition rate (semi-batch) via temperature override.
- High-high temperature trips stop feed and open emergency cooling.
Likely focus at
IOCL, HPCL, BPCL, NRL, MRPL, CPCL, ONGC, Oil India, GAIL, BCPL, EIL, DRDO, NFL, RCF, BVFCL. Organisation names show where a topic is a likely focus because of what the organisation does; they are not claims that a particular question was asked. Recruitment routes change each year, so confirm in the official notification.
Frequently asked questions
How do you control the temperature of an exothermic reactor?
By removing heat through a jacket, coil or external exchanger with a cascade loop (temperature master, coolant flow or temperature slave), with interlocks on high temperature. Why: Heat release rises exponentially with temperature; the control loop must react faster than the reaction can run away.
Related questions
- Explain P, PI and PID control. What does each term do?
- What is the difference between fail-open and fail-close valves? How do you decide?
- What is cascade control? Give an example.
- What is feed-forward and ratio control?
- What is the difference between DCS, PLC and SCADA?
- How is level measured in a pressurised vessel?