Water treatment and hardness, steam tables and boilers, compressed air, IC engines, refrigeration and solar thermal from the ASTU CHE241505 syllabus.
What is inside
- Water hardness, boiler feed and cooling towers
- Steam properties and boiler efficiency
- Compressors, engines and refrigeration
- Solar thermal collectors
Syllabus: ASTU CHE241505 Process Utilities, semester 5, NEP 2020 (2024-25 onwards). Official syllabus PDF.
Introduction to process utilities
Topics: Role of utilities in process plants; types: water, steam, compressed air, inert gas, refrigeration, power, fuel; utility costs; utility integration and energy conservation.
Utilities are the services that let a process run: cooling and process water, steam for heating and power, compressed and instrument air, nitrogen for blanketing, refrigeration, electricity and fuel. They are often 20–40 % of operating cost, so pinch analysis and heat recovery aim to cut hot and cold utility demand. Each utility has a cost per unit (₹/t steam, ₹/kWh, ₹/m³ water) used in economics.
- Hot utilities: steam (LP, MP, HP), hot oil, fired heaters.
- Cold utilities: cooling water (~30 → 40 °C), chilled water, refrigerants.
- Instrument air must be dry (dew point below −40 °C) and oil-free.
- Utility targets come from pinch analysis.
Key formulas
- Utility cost = rate × unit price × operating hours
- Q = ṁ c_p ΔT (cooling water)
- Q = ṁ λ (steam)
Practice questions
Instrument air must be
- wet
- dry and oil-free
- hot
- at 1 atm
Show the answer
Answer: B. dry and oil-free Protects valves and transmitters.
Nitrogen is used in plants mainly for
- heating
- inert blanketing and purging
- cooling towers
- boiler feed
Show the answer
Answer: B. inert blanketing and purging Prevents fires.
Minimum hot and cold utility demands are found by
- pinch analysis
- Fenske equation
- Kick law
- Bernoulli
Show the answer
Answer: A. pinch analysis Composite curves.
Cooling water typically leaves exchangers at about
- 40–45 °C
- 90 °C
- 5 °C
- 150 °C
Show the answer
Answer: A. 40–45 °C Limited by fouling.
Theory questions
A cooler removes 2 MW with cooling water from 30 to 40 °C. Find the water flow. (3 marks)
Show the model answer
ṁ = Q/(c_pΔT) = 2 × 10⁶/(4180 × 10) ≈ 47.8 kg/s ≈ 172 m³/h.
List the utilities in a chemical plant and their uses. (4 marks)
Show the model answer
Water (process, cooling, boiler feed, fire), steam (heating, stripping, turbines), compressed and instrument air, nitrogen (inerting), refrigeration (low-temperature cooling), electricity (motors), fuel (furnaces, boilers).
Water
Topics: Sources and impurities; hardness and alkalinity; treatment for process, cooling and boiler feed: clarification, softening (lime–soda, zeolite, ion exchange), demineralisation, reverse osmosis; boiler water problems: scale, sludge, priming, foaming, caustic embrittlement, corrosion; cooling-water systems.
Raw water carries suspended solids, dissolved salts (Ca²⁺, Mg²⁺ hardness), gases (O₂, CO₂) and organics. Hardness is expressed as mg/L CaCO₃ equivalent: hardness = Σ(mg/L of ion) × 50/(equivalent weight). Lime–soda softening precipitates CaCO₃ and Mg(OH)₂; ion exchange and RO make high-purity boiler feed. Dissolved oxygen is removed by deaeration and hydrazine or sulfite. Untreated boiler water causes scale (poor heat transfer), corrosion, priming and foaming.
- CaCO₃ equivalent = mass × 50/eq. wt (e.g. Ca²⁺ eq. wt 20, Mg²⁺ 12.15).
- Temporary hardness (bicarbonates) is removed by boiling.
- Blowdown limits dissolved solids: B = E·C_f/(C_b − C_f).
- Cooling-tower cycles of concentration = make-up/blowdown (with drift ignored).
Key formulas
- Hardness (as CaCO₃) = Σ m_i × 50/E_i
- Blowdown B = E C_f/(C_b − C_f)
- Make-up M = E + B + drift
Practice questions
Temporary hardness is caused by
- sulphates
- bicarbonates
- chlorides
- nitrates
Show the answer
Answer: B. bicarbonates Removed by boiling.
Equivalent weight of CaCO₃ used for hardness is
- 100
- 50
- 40
- 20
Show the answer
Answer: B. 50 M/2.
Dissolved oxygen in feed water is removed by
- a deaerator
- a cyclone
- a thickener
- a crusher
Show the answer
Answer: A. a deaerator Steam stripping.
Caustic embrittlement is caused by
- high free NaOH in boiler water
- low pH
- silica
- oil
Show the answer
Answer: A. high free NaOH in boiler water Intergranular cracking.
Theory questions
Water has 160 mg/L Ca²⁺ and 48.6 mg/L Mg²⁺. Find total hardness as CaCO₃. (3 marks)
Show the model answer
Ca: 160 × 50/20 = 400; Mg: 48.6 × 50/12.15 = 200; total 600 mg/L as CaCO₃.
Explain scale and sludge formation in boilers and their prevention. (4 marks)
Show the model answer
Scale: hard adherent deposits (CaSO₄, CaSiO₃, Mg(OH)₂) on hot surfaces, insulating them and causing overheating. Sludge: soft loose precipitate removed by blowdown. Prevent by external softening, internal treatment (phosphate, chelants), controlled blowdown.
Steam
Topics: Properties of steam: wet, dry saturated and superheated; dryness fraction; steam tables and Mollier chart; boilers: fire-tube and water-tube, mountings and accessories; boiler efficiency and equivalent evaporation; steam distribution, traps, condensate recovery, flash steam.
Wet steam enthalpy h = h_f + x h_fg (x dryness fraction); superheated steam h = h_g + c_p(T − T_sat). Boiler efficiency = ṁ_s(h − h_feed)/(ṁ_f × GCV). Equivalent evaporation from and at 100 °C = ṁ_s(h − h_feed)/2257 kJ/kg compares boilers. Steam traps discharge condensate without losing steam; recovered condensate saves fuel and water, and high-pressure condensate flashes when let down: flash fraction = (h_f1 − h_f2)/h_fg2.
- Fire-tube: hot gas in tubes (small, low pressure). Water-tube: water in tubes (large, high pressure).
- Mountings: safety valve, water-level gauge, pressure gauge, stop valve, blow-off cock, fusible plug.
- Accessories: economiser, air pre-heater, superheater, feed pump.
- Steam for heating should be dry saturated, at the lowest pressure that gives the needed temperature.
Key formulas
- h = h_f + x h_fg
- η_boiler = ṁ_s(h − h_fw)/(ṁ_f GCV)
- Equivalent evaporation = ṁ_s(h − h_fw)/2257
- Flash fraction = (h_f1 − h_f2)/h_fg2
Practice questions
Enthalpy of wet steam is
- h_g
- h_f + x h_fg
- x h_f
- h_fg
Show the answer
Answer: B. h_f + x h_fg Dryness fraction x.
An economiser heats
- combustion air
- feed water
- steam
- fuel
Show the answer
Answer: B. feed water Using flue gas.
Latent heat at 100 °C and 1 atm is about
- 2257 kJ/kg
- 419 kJ/kg
- 4.18 kJ/kg
- 1000 kJ/kg
Show the answer
Answer: A. 2257 kJ/kg h_fg.
A fusible plug protects a boiler against
- high pressure
- low water level
- scale
- foaming
Show the answer
Answer: B. low water level Melts and lets steam douse the fire.
Theory questions
A boiler makes 10 t/h of steam at 10 bar, dry (h = 2778 kJ/kg) from feed at 60 °C (h = 251 kJ/kg) burning 1.2 t/h coal of GCV 30 MJ/kg. Find efficiency and equivalent evaporation. (5 marks)
Show the model answer
Heat to steam = 10 000 × (2778 − 251) = 25.27 GJ/h; fuel heat = 1200 × 30 000 = 36 GJ/h, so η = 25.27/36 = 70.2 %. Equivalent evaporation = 25.27 × 10⁶/2257 = 11 196 kg/h.
Explain the functions of a steam trap and the types. (4 marks)
Show the model answer
Removes condensate and air while holding back live steam. Mechanical (float, inverted bucket), thermostatic (bellows, bimetal) and thermodynamic (disc) traps.
Compressed air and inert gas
Topics: Air compressors: reciprocating and rotary (screw, centrifugal); work of compression, isothermal and isentropic efficiency; multistage compression with intercooling; volumetric efficiency; air receivers, dryers and distribution; inert gas generation.
Compression work per kg for an ideal gas: isothermal w = RT₁ ln(P₂/P₁) (minimum), polytropic w = (n/(n − 1))RT₁[(P₂/P₁)^((n−1)/n) − 1]. Multistage compression with perfect intercooling saves work; the best intermediate pressure is √(P₁P₂) for two stages (equal pressure ratios). Reciprocating compressors have a clearance volume, so volumetric efficiency η_v = 1 + C − C(P₂/P₁)^(1/n). Air is then cooled, dried (refrigerated or desiccant) and stored in a receiver.
- Isothermal efficiency = isothermal work/actual work.
- Intercooling reduces work and discharge temperature.
- Free air delivery is measured at inlet conditions.
- Nitrogen by PSA or membrane separation of air.
Key formulas
- w_iso = RT₁ ln(P₂/P₁)
- w_poly = (n/(n−1)) RT₁[(P₂/P₁)^((n−1)/n) − 1]
- P_opt = √(P₁P₂) (two stages)
- η_v = 1 + C − C(P₂/P₁)^(1/n)
Practice questions
Minimum compression work is for
- isentropic
- isothermal
- polytropic n = 1.3
- adiabatic irreversible
Show the answer
Answer: B. isothermal n = 1.
For two stages from 1 to 9 bar, the ideal intermediate pressure is
- 5 bar
- 3 bar
- 4.5 bar
- 2 bar
Show the answer
Answer: B. 3 bar √9 = 3.
Volumetric efficiency falls when
- clearance increases
- pressure ratio falls
- speed is low
- intercooler is used
Show the answer
Answer: A. clearance increases Re-expansion.
Nitrogen for blanketing is often made by
- PSA
- electrolysis
- boiling water
- combustion only
Show the answer
Answer: A. PSA Pressure-swing adsorption.
Theory questions
Find the isentropic work to compress 1 kg of air from 1 to 7 bar at 300 K (γ = 1.4, R = 0.287). (3 marks)
Show the model answer
w = (1.4/0.4) × 0.287 × 300 × (7^0.2857 − 1) = 301.35 × (1.744 − 1) ≈ 224 kJ/kg. Isothermal: 0.287 × 300 × ln 7 = 167.5 kJ/kg.
Why is multistage compression with intercooling used? (3 marks)
Show the model answer
It brings the process closer to isothermal, saving work, limits discharge temperature (lubricant safety), improves volumetric efficiency and allows moisture removal between stages.
Internal combustion engines
Topics: Classification; two- and four-stroke engines; SI and CI engines; air-standard Otto, Diesel and dual cycles; performance: indicated and brake power, mechanical and thermal efficiency, specific fuel consumption; diesel generator sets as standby power.
The Otto cycle (SI engines) has efficiency η = 1 − 1/r^(γ−1) depending only on compression ratio r; the Diesel cycle adds the cut-off ratio ρ: η = 1 − (1/r^(γ−1))(ρ^γ − 1)/(γ(ρ − 1)), lower than Otto at the same r, but diesel engines run at higher r (14–22). Brake power BP = 2πNT; indicated power IP = p_m L A n k; mechanical efficiency = BP/IP; brake thermal efficiency = BP/(ṁ_f × CV). In plants, diesel generator sets give emergency power.
- Four-stroke: one power stroke per two revolutions.
- Knock limits r in SI engines (octane number); CI engines rely on cetane number.
- BSFC (kg/kWh) measures fuel economy.
- Heat balance: BP, coolant, exhaust, unaccounted.
Key formulas
- η_Otto = 1 − 1/r^(γ−1)
- η_Diesel = 1 − (1/r^(γ−1))(ρ^γ − 1)/(γ(ρ − 1))
- BP = 2πNT/60
- η_bth = BP/(ṁ_f CV)
Practice questions
Otto efficiency depends only on
- compression ratio and γ
- speed
- fuel
- load
Show the answer
Answer: A. compression ratio and γ η = 1 − r^(1−γ).
At the same compression ratio, Otto efficiency is
- less than Diesel
- more than Diesel
- equal
- zero
Show the answer
Answer: B. more than Diesel Cut-off penalty.
Diesel fuel quality is rated by
- octane number
- cetane number
- API gravity only
- flash point only
Show the answer
Answer: B. cetane number Ignition quality.
In a four-stroke engine the number of power strokes per revolution is
- 1
- 1/2
- 2
- 4
Show the answer
Answer: B. 1/2 One per two revolutions.
Theory questions
Find the Otto efficiency for r = 8 and the Diesel efficiency for r = 18, ρ = 2 (γ = 1.4). (4 marks)
Show the model answer
Otto: 1 − 8^(−0.4) = 1 − 0.435 = 56.5 %. Diesel: 1 − 18^(−0.4) × (2^1.4 − 1)/(1.4 × 1) = 1 − 0.315 × 1.639/1.4 = 1 − 0.369 = 63.1 %.
Compare SI and CI engines. (4 marks)
Show the model answer
SI: petrol, spark plug, Otto cycle, r 6–10, throttle governed, lighter, cheaper. CI: diesel, compression ignition, Diesel cycle, r 14–22, quality governed, higher efficiency, heavier.
Refrigeration
Topics: Refrigeration units (TR); reversed Carnot cycle; vapour-compression cycle on p–h and T–s diagrams; COP; refrigerants and their properties; vapour-absorption refrigeration (NH₃–water, LiBr–water); applications in process industries.
A refrigerator moves heat from cold to hot using work. COP = refrigerating effect/work; Carnot limit COP = T_L/(T_H − T_L). In vapour compression: evaporator h₄→h₁ (refrigeration effect), compressor h₁→h₂ (work), condenser, expansion valve (h₄ = h₃). COP = (h₁ − h₄)/(h₂ − h₁). One tonne of refrigeration = 3.517 kW (211 kJ/min). Absorption systems use heat instead of most of the compressor work, suiting plants with waste steam.
- 1 TR = 3.517 kW.
- Throttling is isenthalpic.
- Refrigerant choice: low GWP and ODP, suitable pressures, non-toxic (R-134a, R-717 ammonia, R-744 CO₂, R-1234yf).
- Absorption COP ≈ 0.6–1.2.
Key formulas
- COP = (h₁ − h₄)/(h₂ − h₁)
- COP_Carnot = T_L/(T_H − T_L)
- Mass flow = Q/(h₁ − h₄)
- 1 TR = 3.517 kW
Practice questions
One tonne of refrigeration is about
- 3.517 kW
- 1 kW
- 10 kW
- 0.746 kW
Show the answer
Answer: A. 3.517 kW 211 kJ/min.
The expansion valve process is
- isentropic
- isenthalpic
- isothermal
- isobaric
Show the answer
Answer: B. isenthalpic Throttling.
Carnot COP between −10 °C and 40 °C is
- 5.26
- 0.25
- 1.26
- 10
Show the answer
Answer: A. 5.26 263/50.
A LiBr–water absorption system uses
- LiBr as refrigerant
- water as refrigerant
- ammonia
- CO₂
Show the answer
Answer: B. water as refrigerant LiBr is the absorbent.
Theory questions
In a vapour-compression cycle h₁ = 395, h₂ = 425, h₃ = h₄ = 255 kJ/kg. For 10 TR find COP, refrigerant flow and power. (4 marks)
Show the model answer
RE = 140 kJ/kg, W = 30 kJ/kg, COP = 4.67. Load = 35.17 kW ⇒ ṁ = 0.251 kg/s; power = 7.54 kW.
Explain the vapour-absorption refrigeration system. (4 marks)
Show the model answer
Compressor is replaced by an absorber (refrigerant vapour absorbed in a weak solution), a pump and a generator (heat drives refrigerant out). Uses low-grade heat, few moving parts, lower COP than compression.
Solar thermal energy
Topics: Solar radiation; flat-plate and evacuated-tube collectors; collector efficiency and the Hottel–Whillier–Bliss equation; concentrating collectors; solar water heating, drying and process heat; thermal storage.
A flat-plate collector absorbs radiation through a glass cover; useful heat Q_u = A_c F_R[S − U_L(T_i − T_a)] with S = I_T(τα). Efficiency η = Q_u/(A_c I_T) falls linearly with (T_i − T_a)/I_T. Evacuated tubes reduce losses at higher temperatures; concentrators (parabolic trough, dish, Fresnel) reach hundreds of °C for process steam. Storage (water tanks, rocks, phase-change salts) covers cloudy periods.
- Solar constant ≈ 1361 W/m²; peak ground irradiance ≈ 1000 W/m².
- F_R is the heat-removal factor (0.7–0.9).
- Selective coatings: high absorptance, low emittance.
- Concentration ratio = aperture area/receiver area.
Key formulas
- Q_u = A_c F_R [I_T(τα) − U_L(T_i − T_a)]
- η = F_R(τα) − F_R U_L(T_i − T_a)/I_T
- Q = ṁ c_p (T_o − T_i)
Practice questions
The solar constant is about
- 1361 W/m²
- 100 W/m²
- 5000 W/m²
- 13.6 W/m²
Show the answer
Answer: A. 1361 W/m² Outside the atmosphere.
Collector efficiency decreases when
- inlet temperature rises
- irradiance rises
- F_R rises
- U_L falls
Show the answer
Answer: A. inlet temperature rises More loss.
Selective surfaces have
- high α, low ε
- low α, high ε
- high α, high ε
- low α, low ε
Show the answer
Answer: A. high α, low ε Absorb but do not re-radiate.
A parabolic trough is a
- flat-plate collector
- concentrating collector
- storage tank
- photovoltaic cell
Show the answer
Answer: B. concentrating collector Line focus.
Theory questions
A 2 m² collector (F_R = 0.8, τα = 0.8, U_L = 6 W/m²K) has I = 800 W/m², T_i = 40 °C, T_a = 30 °C. Find Q_u and η. (4 marks)
Show the model answer
Q_u = 2 × 0.8 × (640 − 60) = 928 W; η = 928/1600 = 58 %.
Describe a flat-plate collector and its losses. (4 marks)
Show the model answer
Absorber plate with tubes, glass cover(s), insulated box. Losses: top (convection and radiation through the cover), bottom and edge conduction, optical reflection. Covers and selective coatings reduce them.
Notes, examples and questions were written for this studio; the prescribed books are listed in the studio for reference.
Frequently asked questions
What is the Process Utilities Studio?
Water, steam, air, cold and sun. Water treatment and hardness, steam tables and boilers, compressed air, IC engines, refrigeration and solar thermal from the ASTU CHE241505 syllabus.
What can I do in the Process Utilities Studio?
Water hardness, boiler feed and cooling towers; Steam properties and boiler efficiency; Compressors, engines and refrigeration; Solar thermal collectors.
Is the Process Utilities Studio free?
Yes. It is free and runs in your browser with no sign-up.