CRO, meters, generators and transducers
Topics: Errors and accuracy; analog and digital multimeters; CRO and DSO; signal generators; frequency counters; Q-meter, spectrum analyser, logic analyser; bridges; transducers and data acquisition.
Errors, accuracy and meters
Accuracy is closeness to the true value; precision is repeatability; resolution is the smallest detectable change. Errors are gross, systematic or random. A meter’s accuracy given as ±% of full scale gives a larger percentage error at low readings, so readings near full scale are better. A 3½-digit DMM reads up to 1999.
- % error = (measured − true)/true × 100
- ±% FSD hurts low readings
- Accuracy vs precision vs resolution
Example: A voltmeter reads 102 V when the true value is 100 V. Find the % error.
- (102 − 100)/100 × 100.
- = 2 %.
Answer: 2 %
Example: A 0–100 V meter is ±1 % of full scale. What is the possible error at 20 V, as a % of reading?
- ±1 % of 100 V = ±1 V.
- ±1/20 = ±5 % of the reading.
Answer: ±5 %
Oscilloscopes and signal generators
A CRO or DSO plots voltage against time. Period = divisions × time/div; frequency = 1/period; peak-to-peak voltage = divisions × volts/div. Lissajous figures compare two frequencies: f_y/f_x = number of horizontal tangencies ÷ number of vertical tangencies. Function generators give sine, square and triangle waves; spectrum analysers show frequency content.
- T = divisions × time/div
- V_pp = divisions × volts/div
- Lissajous ratio from tangencies
Example: One cycle spans 4 divisions at 0.5 ms/div. Find the frequency.
- T = 4 × 0.5 = 2 ms.
- f = 1/0.002 = 500 Hz.
Answer: 500 Hz
Example: A sine wave spans 3 divisions peak to peak at 2 V/div. Find its RMS value.
- V_pp = 6 V, so V_m = 3 V.
- V_rms = 3/√2 ≈ 2.12 V.
Answer: ≈ 2.1 V
Transducers and bridges
Transducers turn physical quantities into electrical signals: strain gauges (gauge factor GF = (ΔR/R)/ε), LVDTs for displacement, thermocouples, RTDs and thermistors for temperature, piezoelectric crystals for force and vibration, photodiodes for light. Bridges (Wheatstone, Maxwell, Schering) measure R, L and C; a Q-meter measures coil quality.
- GF = (ΔR/R)/ε
- LVDT: displacement
- Type K ≈ 41 µV/°C
Example: A 120 Ω strain gauge changes by 0.24 Ω at strain 0.001. Find the gauge factor.
- ΔR/R = 0.002.
- GF = 0.002/0.001 = 2.
Answer: 2
Example: A type K thermocouple gives about 41 µV/°C. Estimate its output for a 100 °C difference.
- 41 × 100 µV.
- ≈ 4.1 mV.
Answer: ≈ 4.1 mV
Accuracy is closeness to the true value, precision is repeatability, and sensitivity of a voltmeter is the ohms-per-volt rating. A CRO deflects an electron beam by vertical and horizontal plates; a sawtooth time base gives the sweep; Lissajous figures compare frequency and phase. A DMM digitises input, commonly with a dual-slope integrating ADC. A function generator gives sine, square and triangle waves. A spectrum analyser shows amplitude against frequency, and a logic analyser shows many digital channels. A Q-meter uses series resonance to measure coil quality.
- A voltmeter should have high input resistance to avoid loading.
- CRO: electron gun, deflection plates, phosphor screen.
- Frequency counters count pulses in a gate time.
- Bridges: Wheatstone (R), Maxwell (L), Schering (C), Wien (f).
- Peak-to-peak V_pp = 2√2 V_rms for a sine.
Key formulas
- S = 1/I_fsd Ω/V
- V_pp = 2√2 V_rms
- f_y/f_x = horizontal/vertical tangencies
Practice questions
A CRO’s time base waveform is
- sine
- square
- sawtooth
- triangle always
Show the answer
Answer: C. sawtooth Linear sweep.
Lissajous patterns are used to find
- frequency and phase
- resistance
- current only
- power only
Show the answer
Answer: A. frequency and phase XY mode.
An ideal voltmeter has input resistance
- zero
- infinite
- 50 Ω
- 1 Ω
Show the answer
Answer: B. infinite No loading.
Dual-slope ADCs are valued for
- very high speed
- noise rejection
- large output
- no reference
Show the answer
Answer: B. noise rejection Integration averages.
A spectrum analyser displays
- amplitude vs frequency
- amplitude vs time
- current vs voltage
- phase only
Show the answer
Answer: A. amplitude vs frequency Frequency domain.
A Q-meter operates on
- series resonance
- rectification
- digital logic
- beat notes only
Show the answer
Answer: A. series resonance Voltage magnification.
Voltmeter sensitivity is expressed in
- Ω/V
- V/Ω
- A/V
- W/V
Show the answer
Answer: A. Ω/V ohms per volt.
Repeatability of readings is
- accuracy
- precision
- sensitivity
- range
Show the answer
Answer: B. precision Consistency.
A Wien bridge can measure
- frequency
- resistivity
- temperature only
- torque
Show the answer
Answer: A. frequency Also capacitance.
A logic analyser is used for
- many digital channels
- audio power
- high voltage
- insulation
Show the answer
Answer: A. many digital channels Timing and state.
The practice questions were written for this studio; they are not copied from ASTU papers. ASTU publishes no topic syllabus for these exams, so the topics are an informed guide based on diploma courses, not an official list.