IITIAN1997 STUDIO

Electrical measurement and instruments

JLEE EE · 10 practice questions with answers

Practise and take a mock test →

Indicating instruments, bridges, power and energy measurement

Topics: Units and standards; PMMC and moving-iron instruments, range extension; measurement of resistance, potentiometers, bridges; wattmeters, energy meters; CT and PT; special instruments (megger, power factor meter, frequency meter); electronic instruments, sensors.

Indicating instruments and range extension

PMMC instruments are accurate with a uniform scale but work on DC only; moving-iron instruments work on AC and DC with a square-law scale. An ammeter’s range is extended by a shunt R_sh = I_mR_m/(I − I_m); a voltmeter’s by a series multiplier R_s = V/I_m − R_m. Ammeters have very low resistance and go in series; voltmeters very high resistance, in parallel.

  • PMMC: DC only, uniform scale
  • Shunt R_sh = I_mR_m/(I − I_m)
  • Multiplier R_s = V/I_m − R_m

Example: A meter with R_m = 5 Ω reads 10 mA full scale. Find the shunt for a 1 A range.

  1. R_sh = 0.01 × 5/(1 − 0.01).
  2. ≈ 0.0505 Ω.

Answer: ≈ 0.05 Ω

Example: A 1 mA, 100 Ω meter is to read 100 V. Find the multiplier.

  1. R_s = 100/0.001 − 100.
  2. = 99 900 Ω.

Answer: 99.9 kΩ

Measuring resistance

Medium resistances are measured with a Wheatstone bridge: at balance P/Q = R/X, so X = QR/P (with the arms named accordingly). Low resistances use Kelvin’s double bridge; high (insulation) resistances use a megger, which applies 500 V–5 kV DC. Potentiometers compare EMFs without drawing current.

  • Wheatstone: X = R₂R₃/R₁ at balance
  • Kelvin double bridge: low R
  • Megger: insulation resistance

Example: A Wheatstone bridge balances with R₁ = 200 Ω, R₂ = 100 Ω and R₃ = 50 Ω. Find the unknown X = R₂R₃/R₁.

  1. X = 100 × 50/200.
  2. = 25 Ω.

Answer: 25 Ω

Example: Which instrument tests the insulation of a motor winding?

  1. Insulation resistance is in megohms and needs a high test voltage.
  2. A megger (insulation tester).

Answer: Megger

Power, energy and instrument transformers

The two-wattmeter method measures three-phase power: P = W₁ + W₂ and tan φ = √3(W₁ − W₂)/(W₁ + W₂). Energy meters count revolutions or pulses per kWh (meter constant). Current and potential transformers step down large quantities for meters and relays; a CT secondary must never be open-circuited (dangerous voltage).

  • P = W₁ + W₂
  • tan φ = √3(W₁ − W₂)/(W₁ + W₂)
  • Never open a CT secondary on load

Example: Two wattmeters read 3 kW and 1 kW. Find the power and power factor.

  1. P = 4 kW; tan φ = √3 × 2/4 ≈ 0.866, φ ≈ 40.9°.
  2. pf = cos 40.9° ≈ 0.76.

Answer: 4 kW; ≈ 0.76

Example: A meter of 1200 rev/kWh makes 60 revolutions in 3 minutes. Find the load.

  1. Energy = 60/1200 = 0.05 kWh in 0.05 h.
  2. Power = 0.05/0.05 = 1 kW.

Answer: 1 kW

Instruments need deflecting, controlling and damping torques. PMMC instruments read DC only with a uniform scale; moving-iron instruments read AC or DC with a non-uniform scale. A shunt extends an ammeter (R_sh = R_m/(m − 1)) and a multiplier extends a voltmeter (R_se = R_m(m − 1)). Low resistance is measured by Kelvin’s double bridge, medium resistance by Wheatstone’s bridge, and high insulation resistance by a megger. Anderson and Maxwell bridges measure inductance; Schering measures capacitance. A dynamometer wattmeter has a current coil in series and a pressure coil across the load, and an induction energy meter is integrating. The CT secondary must never be opened under load.

  • PMMC uses eddy current damping; moving iron, air friction damping.
  • Wheatstone balance: P/Q = R/S.
  • CT secondary rating commonly 5 A; PT secondary 110 V.
  • A CRO shows waveforms; Lissajous figures give frequency and phase.
  • Accuracy, precision, sensitivity and resolution are distinct.

Key formulas

  • R_sh = R_m/(m − 1)
  • R_se = R_m(m − 1)
  • P/Q = R/S
  • E = Pt

Practice questions

A PMMC instrument measures

  1. DC only
  2. AC only
  3. both AC and DC
  4. high-frequency AC
Show the answer

Answer: A. DC only Torque reverses with AC.

Ammeter range is extended by a

  1. high series resistance
  2. low shunt resistance
  3. capacitor
  4. transformer only
Show the answer

Answer: B. low shunt resistance Bypass path.

Voltmeter range is extended by a

  1. high series resistance
  2. low shunt resistance
  3. inductor
  4. diode
Show the answer

Answer: A. high series resistance Multiplier.

Insulation resistance is measured by a

  1. megger
  2. Wheatstone bridge
  3. Kelvin bridge
  4. potentiometer
Show the answer

Answer: A. megger High-voltage tester.

Very low resistance is measured by

  1. Kelvin’s double bridge
  2. a megger
  3. Schering bridge
  4. Hay’s bridge
Show the answer

Answer: A. Kelvin’s double bridge Eliminates lead resistance.

Capacitance is measured by

  1. Schering bridge
  2. Maxwell bridge
  3. Kelvin bridge
  4. megger
Show the answer

Answer: A. Schering bridge High voltage too.

The secondary of a CT should not be

  1. shorted
  2. opened under load
  3. earthed
  4. connected to an ammeter
Show the answer

Answer: B. opened under load Dangerous high voltage.

An energy meter is an

  1. indicating instrument
  2. integrating instrument
  3. absolute instrument
  4. recording instrument
Show the answer

Answer: B. integrating instrument Sums over time.

Damping in an instrument

  1. deflects the pointer
  2. brings the pointer quickly to rest
  3. returns it to zero
  4. increases range
Show the answer

Answer: B. brings the pointer quickly to rest Prevents oscillation.

Wattmeter current coil is connected

  1. in parallel with load
  2. in series with load
  3. across supply only
  4. to earth
Show the answer

Answer: B. in series with load Pressure coil is across.

The practice questions were written for this studio; they are not copied from ASTU papers. ASTU publishes no topic syllabus for these exams, so the topics are an informed guide based on diploma courses, not an official list.