Indicating instruments, bridges, power and energy measurement
Topics: Units and standards; PMMC and moving-iron instruments, range extension; measurement of resistance, potentiometers, bridges; wattmeters, energy meters; CT and PT; special instruments (megger, power factor meter, frequency meter); electronic instruments, sensors.
Indicating instruments and range extension
PMMC instruments are accurate with a uniform scale but work on DC only; moving-iron instruments work on AC and DC with a square-law scale. An ammeter’s range is extended by a shunt R_sh = I_mR_m/(I − I_m); a voltmeter’s by a series multiplier R_s = V/I_m − R_m. Ammeters have very low resistance and go in series; voltmeters very high resistance, in parallel.
- PMMC: DC only, uniform scale
- Shunt R_sh = I_mR_m/(I − I_m)
- Multiplier R_s = V/I_m − R_m
Example: A meter with R_m = 5 Ω reads 10 mA full scale. Find the shunt for a 1 A range.
- R_sh = 0.01 × 5/(1 − 0.01).
- ≈ 0.0505 Ω.
Answer: ≈ 0.05 Ω
Example: A 1 mA, 100 Ω meter is to read 100 V. Find the multiplier.
- R_s = 100/0.001 − 100.
- = 99 900 Ω.
Answer: 99.9 kΩ
Measuring resistance
Medium resistances are measured with a Wheatstone bridge: at balance P/Q = R/X, so X = QR/P (with the arms named accordingly). Low resistances use Kelvin’s double bridge; high (insulation) resistances use a megger, which applies 500 V–5 kV DC. Potentiometers compare EMFs without drawing current.
- Wheatstone: X = R₂R₃/R₁ at balance
- Kelvin double bridge: low R
- Megger: insulation resistance
Example: A Wheatstone bridge balances with R₁ = 200 Ω, R₂ = 100 Ω and R₃ = 50 Ω. Find the unknown X = R₂R₃/R₁.
- X = 100 × 50/200.
- = 25 Ω.
Answer: 25 Ω
Example: Which instrument tests the insulation of a motor winding?
- Insulation resistance is in megohms and needs a high test voltage.
- A megger (insulation tester).
Answer: Megger
Power, energy and instrument transformers
The two-wattmeter method measures three-phase power: P = W₁ + W₂ and tan φ = √3(W₁ − W₂)/(W₁ + W₂). Energy meters count revolutions or pulses per kWh (meter constant). Current and potential transformers step down large quantities for meters and relays; a CT secondary must never be open-circuited (dangerous voltage).
- P = W₁ + W₂
- tan φ = √3(W₁ − W₂)/(W₁ + W₂)
- Never open a CT secondary on load
Example: Two wattmeters read 3 kW and 1 kW. Find the power and power factor.
- P = 4 kW; tan φ = √3 × 2/4 ≈ 0.866, φ ≈ 40.9°.
- pf = cos 40.9° ≈ 0.76.
Answer: 4 kW; ≈ 0.76
Example: A meter of 1200 rev/kWh makes 60 revolutions in 3 minutes. Find the load.
- Energy = 60/1200 = 0.05 kWh in 0.05 h.
- Power = 0.05/0.05 = 1 kW.
Answer: 1 kW
Instruments need deflecting, controlling and damping torques. PMMC instruments read DC only with a uniform scale; moving-iron instruments read AC or DC with a non-uniform scale. A shunt extends an ammeter (R_sh = R_m/(m − 1)) and a multiplier extends a voltmeter (R_se = R_m(m − 1)). Low resistance is measured by Kelvin’s double bridge, medium resistance by Wheatstone’s bridge, and high insulation resistance by a megger. Anderson and Maxwell bridges measure inductance; Schering measures capacitance. A dynamometer wattmeter has a current coil in series and a pressure coil across the load, and an induction energy meter is integrating. The CT secondary must never be opened under load.
- PMMC uses eddy current damping; moving iron, air friction damping.
- Wheatstone balance: P/Q = R/S.
- CT secondary rating commonly 5 A; PT secondary 110 V.
- A CRO shows waveforms; Lissajous figures give frequency and phase.
- Accuracy, precision, sensitivity and resolution are distinct.
Key formulas
- R_sh = R_m/(m − 1)
- R_se = R_m(m − 1)
- P/Q = R/S
- E = Pt
Practice questions
A PMMC instrument measures
- DC only
- AC only
- both AC and DC
- high-frequency AC
Show the answer
Answer: A. DC only Torque reverses with AC.
Ammeter range is extended by a
- high series resistance
- low shunt resistance
- capacitor
- transformer only
Show the answer
Answer: B. low shunt resistance Bypass path.
Voltmeter range is extended by a
- high series resistance
- low shunt resistance
- inductor
- diode
Show the answer
Answer: A. high series resistance Multiplier.
Insulation resistance is measured by a
- megger
- Wheatstone bridge
- Kelvin bridge
- potentiometer
Show the answer
Answer: A. megger High-voltage tester.
Very low resistance is measured by
- Kelvin’s double bridge
- a megger
- Schering bridge
- Hay’s bridge
Show the answer
Answer: A. Kelvin’s double bridge Eliminates lead resistance.
Capacitance is measured by
- Schering bridge
- Maxwell bridge
- Kelvin bridge
- megger
Show the answer
Answer: A. Schering bridge High voltage too.
The secondary of a CT should not be
- shorted
- opened under load
- earthed
- connected to an ammeter
Show the answer
Answer: B. opened under load Dangerous high voltage.
An energy meter is an
- indicating instrument
- integrating instrument
- absolute instrument
- recording instrument
Show the answer
Answer: B. integrating instrument Sums over time.
Damping in an instrument
- deflects the pointer
- brings the pointer quickly to rest
- returns it to zero
- increases range
Show the answer
Answer: B. brings the pointer quickly to rest Prevents oscillation.
Wattmeter current coil is connected
- in parallel with load
- in series with load
- across supply only
- to earth
Show the answer
Answer: B. in series with load Pressure coil is across.
The practice questions were written for this studio; they are not copied from ASTU papers. ASTU publishes no topic syllabus for these exams, so the topics are an informed guide based on diploma courses, not an official list.