DC generators, DC motors and transformers
Topics: DC machine construction, EMF equation, armature reaction, commutation; types of generators and motors, characteristics, torque, starting and speed control; losses and efficiency; single-phase and three-phase transformers, EMF equation, equivalent circuit, regulation, efficiency, tests, parallel operation.
DC generators
Generated EMF E = PΦZN/(60A): P poles, Φ flux per pole, Z conductors, N rpm, A parallel paths (A = P for lap winding, 2 for wave). In a shunt generator the terminal voltage V = E − I_aR_a. Armature reaction distorts the field; interpoles and compensating windings improve commutation.
Types: separately excited, shunt, series and compound. A self-excited generator needs residual magnetism and field resistance below the critical value.
- E = PΦZN/(60A)
- Lap A = P; wave A = 2
- V = E − I_aR_a
Example: A 4-pole lap-wound generator has Φ = 0.02 Wb, Z = 500 and runs at 1000 rpm. Find E.
- A = P = 4, so E = ΦZN/60.
- = 0.02 × 500 × 1000/60 ≈ 166.7 V.
Answer: ≈ 167 V
Example: A shunt generator supplies I_a = 50 A at 220 V with R_a = 0.1 Ω. Find the generated EMF.
- E = V + I_aR_a.
- = 220 + 5 = 225 V.
Answer: 225 V
DC motors
A motor develops a back EMF E_b = V − I_aR_a that limits current once it runs; at starting E_b = 0, so a starter resistance is needed. Speed N ∝ E_b/Φ; torque T ∝ ΦI_a, T = 9.55 E_bI_a/N. Shunt motors run at nearly constant speed; series motors give high starting torque (traction, cranes) but must never run without load, or they race.
Speed control: field (flux) control above normal speed, armature voltage control below it.
- E_b = V − I_aR_a
- N ∝ E_b/Φ
- Series motor: never on no load
Example: A 230 V motor has R_a = 0.5 Ω and draws I_a = 20 A. Find the back EMF.
- E_b = 230 − 20 × 0.5.
- = 220 V.
Answer: 220 V
Example: Why is a DC series motor never started without load?
- With little load the current and flux fall, and N ∝ E_b/Φ rises dangerously.
- The motor could overspeed and burst.
Answer: It would overspeed
Transformers
EMF equation E = 4.44 f N Φ_m. Turns ratio N₁/N₂ = V₁/V₂ = I₂/I₁. Losses: iron (core) losses, constant at any load; copper losses, proportional to load squared. Efficiency is greatest when copper loss equals iron loss. Voltage regulation is the change in secondary voltage from no load to full load as a percentage.
- E = 4.44 f N Φ_m
- V₁/V₂ = N₁/N₂ = I₂/I₁
- Max efficiency: Cu loss = iron loss
Example: A 200-turn winding on a 50 Hz core with Φ_m = 0.01 Wb: find E.
- E = 4.44 × 50 × 200 × 0.01.
- = 444 V.
Answer: 444 V
Example: A 10 kVA transformer at 0.8 pf has iron loss 200 W and full-load copper loss 300 W. Find full-load efficiency.
- Output = 8000 W; input = 8000 + 500 = 8500 W.
- η = 8000/8500 ≈ 94.1 %.
Answer: ≈ 94 %
A DC generator’s EMF is E = PΦZN/(60A), with A = 2 for wave and A = P for lap winding. A motor’s back EMF is E_b = V − I_aR_a and speed N ∝ E_b/Φ, torque T ∝ ΦI_a. Series motors have high starting torque but must never run unloaded, and shunt motors are near constant speed. A starter limits starting current. Speed control by field flux gives above-rated speed, and by armature voltage gives below-rated speed. A transformer’s EMF is E = 4.44fNΦ_m, with V₁/V₂ = N₁/N₂ = I₂/I₁. Its iron loss is constant and copper loss varies with load squared; maximum efficiency occurs when they are equal. Open-circuit test gives iron loss, and short-circuit test gives copper loss.
- Commutator converts AC in the armature to DC at the brushes.
- Armature reaction distorts and weakens the main field.
- Three-point starter for shunt motors; four-point allows wide field control.
- Voltage regulation = (V_NL − V_FL)/V_FL × 100.
- Parallel operation needs same polarity, voltage ratio, per-unit impedance; for three-phase also phase sequence and vector group.
Key formulas
- E = PΦZN/(60A)
- E_b = V − I_aR_a
- T = 0.159 PΦZI_a/A
- E = 4.44fNΦ_m
- V₁/V₂ = N₁/N₂
Practice questions
A DC series motor should not run
- with full load
- without load
- on DC
- at low speed
Show the answer
Answer: B. without load Dangerous overspeed.
Back EMF in a DC motor is
- V + I_aR_a
- V − I_aR_a
- I_aR_a
- V/R_a
Show the answer
Answer: B. V − I_aR_a Opposes supply.
The commutator in a DC generator does
- AC to DC conversion
- DC to AC conversion
- voltage boost
- cooling
Show the answer
Answer: A. AC to DC conversion Mechanical rectifier.
A transformer works on
- DC
- mutual induction
- static charge
- magnetostriction only
Show the answer
Answer: B. mutual induction Changing flux.
Transformer core is laminated to reduce
- copper loss
- eddy current loss
- hysteresis only
- windage
Show the answer
Answer: B. eddy current loss Thin insulated sheets.
Transformer maximum efficiency occurs when
- copper loss = iron loss
- copper loss = 0
- iron loss = 0
- load is zero
Show the answer
Answer: A. copper loss = iron loss Losses equal.
An open-circuit test on a transformer gives
- copper loss
- iron loss
- load loss
- regulation directly
Show the answer
Answer: B. iron loss Rated voltage, no load.
A short-circuit test on a transformer gives
- copper loss
- iron loss
- hysteresis only
- windage
Show the answer
Answer: A. copper loss At rated current.
Field-flux control of a DC shunt motor gives speed
- above rated
- below rated
- zero
- constant
Show the answer
Answer: A. above rated N ∝ 1/Φ.
Wave winding has number of parallel paths
- 2
- P
- 2P
- 4
Show the answer
Answer: A. 2 A = 2.
Starting torque is highest for a DC
- shunt motor
- series motor
- separately excited motor
- stepper motor
Show the answer
Answer: B. series motor T ∝ I_a².
The practice questions were written for this studio; they are not copied from ASTU papers. ASTU publishes no topic syllabus for these exams, so the topics are an informed guide based on diploma courses, not an official list.