Measurement and control of process variables
Topics: Temperature (thermocouples, RTD, thermistor, pyrometers), pressure (manometers, Bourdon gauge, diaphragm), flow and level measurement, static and dynamic characteristics; first-order systems and time constant; controllers (on–off, P, PI, PID), offset, feedback and feed-forward control, control valves.
Measuring temperature and pressure
Thermocouples produce a voltage from two dissimilar metals (Seebeck effect); types K and J are common. Resistance thermometers (RTDs, e.g. Pt100) follow R = R₀(1 + αT) with α ≈ 0.00385/°C for platinum. Thermistors are very sensitive but non-linear. Pyrometers measure hot bodies by their radiation.
Pressure: manometers for low pressures, Bourdon tubes for gauges, diaphragms and strain-gauge transmitters. Absolute pressure = gauge pressure + atmospheric pressure.
- RTD: R = R₀(1 + αT)
- Thermocouple: Seebeck voltage
- p_abs = p_gauge + p_atm
Example: A Pt100 RTD (α = 0.00385/°C) is at 100 °C. Find its resistance.
- R = 100(1 + 0.00385 × 100).
- = 138.5 Ω.
Answer: 138.5 Ω
Example: A gauge reads 2 bar. Find the absolute pressure.
- p_abs = 2 + 1.013.
- ≈ 3.01 bar.
Answer: ≈ 3.01 bar (abs)
Flow and level measurement
Head-type flow meters (orifice, venturi) give Q ∝ √Δp, so a fourfold rise in differential pressure means twice the flow. Magnetic meters suit conductive liquids; rotameters are simple variable-area meters. Level: sight glass, float, differential pressure (Δp = ρgh), ultrasonic and radar.
- Q ∝ √Δp
- DP level: h = Δp/ρg
- Magnetic meter needs a conductive liquid
Example: An orifice’s differential pressure rises from 4 to 16 kPa. By what factor has the flow changed?
- Q ∝ √Δp, so the ratio is √(16/4).
- = 2: the flow has doubled.
Answer: Doubled
Example: A water tank is 2 m deep. What does a DP level transmitter at the bottom read?
- Δp = ρgh = 1000 × 9.81 × 2.
- ≈ 19.6 kPa.
Answer: ≈ 19.6 kPa
Process dynamics and control
A first-order system responds to a step by reaching 63.2 % of the final change after one time constant τ, 95 % after 3τ and 98 % after 4τ. Controllers: on–off (simple, cycles), proportional (leaves an offset), PI (integral removes offset), PID (derivative adds anticipation). Proportional band PB = 100/Kc %.
Feedback control corrects after an error appears; feed-forward measures a disturbance and acts before it affects the output. Control valves are air-to-open (fail closed) or air-to-close (fail open), chosen for safety.
- 63.2 % at τ; 95 % at 3τ
- P leaves offset; I removes it
- PB = 100/Kc %
Example: A thermometer with τ = 5 s is plunged into hot water. What fraction of the change does it show after 15 s?
- 15 s = 3τ.
- 1 − e⁻³ ≈ 0.95 = 95 %.
Answer: 95 %
Example: A proportional controller has a proportional band of 50 %. Find its gain.
- Kc = 100/PB.
- = 100/50 = 2.
Answer: 2
A thermocouple produces an EMF from the junction of two metals (Seebeck effect); an RTD (platinum) changes resistance nearly linearly with temperature; a thermistor has a large negative coefficient; radiation pyrometers measure very hot bodies without contact. A Bourdon tube straightens under pressure. A first-order instrument reaches 63.2% of a step change in one time constant τ. Proportional control leaves a steady-state offset; integral action removes the offset; derivative action anticipates changes and improves stability. A fail-safe valve (air-to-open or air-to-close) is chosen so the plant is safe on air failure.
- Thermocouple types: J (iron–constantan), K (chromel–alumel), R/S (Pt–Rh) for high temperatures.
- Accuracy: closeness to the true value; precision: repeatability.
- Dead time is a pure delay in the response.
- Proportional band = 100/K_c (%).
- Cascade control uses a secondary loop inside the primary.
Key formulas
- y(t) = KA(1 − e^(−t/τ))
- PB = 100/K_c
- u = K_c(e + (1/τᵢ)∫e dt + τ_d de/dt)
Practice questions
A thermocouple works on the
- Peltier effect
- Seebeck effect
- Hall effect
- Joule effect
Show the answer
Answer: B. Seebeck effect Thermo-EMF.
A first-order system reaches what fraction of a step change in one time constant?
- 50%
- 63.2%
- 86.5%
- 100%
Show the answer
Answer: B. 63.2% 1 − e⁻¹.
Offset is removed by
- proportional action
- integral action
- derivative action
- on–off control
Show the answer
Answer: B. integral action Reset action.
Which sensor has a large negative temperature coefficient?
- RTD
- thermistor
- thermocouple
- bimetal
Show the answer
Answer: B. thermistor Semiconductor.
Very high furnace temperatures are measured with a
- mercury thermometer
- radiation pyrometer
- RTD
- bimetallic strip
Show the answer
Answer: B. radiation pyrometer Non-contact.
A Bourdon tube measures
- flow
- pressure
- level
- temperature
Show the answer
Answer: B. pressure Pressure gauge.
Derivative action responds to the
- error
- integral of error
- rate of change of error
- set point only
Show the answer
Answer: C. rate of change of error Anticipatory.
Proportional band of a controller with gain 4 is
- 4%
- 25%
- 40%
- 400%
Show the answer
Answer: B. 25% 100/4.
Repeatability of readings is called
- accuracy
- precision
- sensitivity
- resolution
Show the answer
Answer: B. precision Precision.
Feed-forward control acts on
- the measured disturbance
- the controlled variable
- the offset
- noise
Show the answer
Answer: A. the measured disturbance Before the error appears.
Which material is NOT used in thermocouples?
- Alumel
- Rhodium
- Constantan
- Duralumin
Show the answer
Answer: D. Duralumin
The Laplace transform of sin t is
- 1/(s²+1)
- s/(1+s²)
- 1/(s²-1)
- s/(s²-1)
Show the answer
Answer: A. 1/(s²+1)
The transfer function of a first-order system is
- 1/(Ts+1)
- 1/Ts
- s/(Ts+1)
- none of these
Show the answer
Answer: A. 1/(Ts+1)
Which of these is a first-order system?
- Damped vibrator.
- Mercury in glass thermometer kept in boiling water.
- Interacting system of two tanks in series.
- Non-interacting system of two tanks in series.
Show the answer
Answer: B. Mercury in glass thermometer kept in boiling water.
The response of a system to a sinusoidal input is its ____ response.
- impluse
- unit step
- frequency
- none of these
Show the answer
Answer: C. frequency
For a first-order system under sinusoidal forcing, the amplitude ratio (output/input) is
- 1
- >1
- <1
- none of these
Show the answer
Answer: C. <1
The phase lag of a first-order system under sinusoidal forcing lies between 0 and
- 120°
- 30°
- 180°
- 90°
Show the answer
Answer: D. 90°
The time constant of a first-order system is the
- time taken by the controlled variable to reach 63.2% of its full change.
- same as transportation lag.
- same as dead time.
- time required by the measured variable to reach 63.2% of its ultimate change.
Show the answer
Answer: A. time taken by the controlled variable to reach 63.2% of its full change.
For two non-interacting first-order systems in series, the overall transfer function is the ____ of the individual ones.
- product
- ratio
- sum
- difference
Show the answer
Answer: A. product
The transfer function of a second-order system is
- 1/(T²s² + 2ζTs + 1)
- 1/(T²s² + 2Ts + 1)
- 1/(T²s² + 2ζT + 1)
- none of these
Show the answer
Answer: A. 1/(T²s² + 2ζTs + 1)
A system with damping coefficient equal to 1 is
- Overdamped.
- Critically damped.
- Underdamped.
- Highly fluctuating.
Show the answer
Answer: B. Critically damped.
For a second-order system under sinusoidal forcing, the phase lag
- is 30°
- is 90° at the most
- approaches 180° asymptotically
- is 120°
Show the answer
Answer: C. approaches 180° asymptotically
The dead zone of an instrument is the
- same as time constant.
- same as transportation lag.
- maximum change in the variable that does not change the reading of the instrument.
- none of these
Show the answer
Answer: C. maximum change in the variable that does not change the reading of the instrument.
The transfer function of a transportation (dead-time) lag is
- e^TS
- e^-TS
- 1/(Ts+1)
- none of these
Show the answer
Answer: B. e^-TS
The response of a control system to a change in set point is the
- frequency response
- transient response
- servo problem
- regulator problem
Show the answer
Answer: C. servo problem
For a response free of offset and with little oscillation, the best controller is
- proportional controller.
- proportional-derivative (PD) controller.
- proportional-integral (PI) controller.
- proportional-integral-derivative (PID) controller.
Show the answer
Answer: D. proportional-integral-derivative (PID) controller.
For an underdamped second-order system,
- decay ratio = overshoot
- decay ratio = (overshoot)²
- overshoot increases for increasing damping co-efficient.
- large damping co-efficient means smaller damping.
Show the answer
Answer: B. decay ratio = (overshoot)²
A stable system is one
- for which the output response is bounded for all bounded input.
- which exhibits an unbounded response to a bounded input
- which satisfies the conditions for a servo problem.
- none of these.
Show the answer
Answer: A. for which the output response is bounded for all bounded input.
The stability of a loop containing dead time is best analysed by
- Routh test
- root locus methods
- frequency response methods
- none of these
Show the answer
Answer: C. frequency response methods
An amplitude ratio is converted to decibels by
- Decibel = 20 log10 (AR)
- Decibel = 20 loge (AR)
- Decibel = 20 log10 (AR)^0.5
- Decibel = 20 loge (AR)^0.5
Show the answer
Answer: A. Decibel = 20 log10 (AR)
“A loop is unstable if the open-loop amplitude ratio exceeds 1 at the crossover frequency” is the ____ criterion.
- Bode stability
- Nyquist
- Routh stability
- none of these
Show the answer
Answer: A. Bode stability
Typical design specifications ask for gain margin and phase margin of
- >1.7 and >30°
- <1.7 and >30°
- <1.7 and <30°
- >1.7 and <30°
Show the answer
Answer: A. >1.7 and >30°
The frequency at which the amplitude ratio peaks is the ____ frequency.
- corner
- resonant
- cross-over
- natural
Show the answer
Answer: B. resonant
A negative gain margin in decibels indicates a/an ____ system.
- stable
- unstable
- critically damped
- none of these
Show the answer
Answer: B. unstable
A Bode diagram plots
- log (AR) vs. log (f) and φ vs. log (f).
- log (AR) vs. f and log φ vs. f.
- AR vs. log (f) and φ vs. log (f).
- none of these.
Show the answer
Answer: A. log (AR) vs. log (f) and φ vs. log (f).
The temperature of a red-hot furnace is best measured with a
- Platinum resistance thermometer
- Thermocouple
- Optical pyrometer
- Bimetallic thermometer
Show the answer
Answer: C. Optical pyrometer
An instrument’s ability to follow changes in the measured variable without dynamic error is its
- speed of response
- reproducibility
- fideility
- static characteristics
Show the answer
Answer: C. fideility
Which is a desirable instrument characteristic?
- High drift
- High fidelity
- High measuring lag
- Poor reproducibility
Show the answer
Answer: B. High fidelity
Which thermometer shows a noticeable initial “dip” (reading briefly moving the wrong way) on sudden heating?
- Mercury thermometer
- Radiation pyrometer
- Bimetallic thermometer
- Thermocouple
Show the answer
Answer: A. Mercury thermometer
For temperatures between −40 and 425 °C, a simple suitable instrument is a
- mercury thermometer
- bimetallic thermometer
- radiation pyrometer
- none of these
Show the answer
Answer: B. bimetallic thermometer
Thermocouples can measure
- liquid temperatures only.
- very high temperatures only.
- very low temperatures only.
- both high and low temperatures
Show the answer
Answer: D. both high and low temperatures
Heat absorbed or released at thermocouple junctions when current flows is the
- Seebeck effect
- Peltier effect
- Joule heating effect
- Thomson effect
Show the answer
Answer: B. Peltier effect
Thermowells are used in temperature measurement to
- guard against corrosive and oxidising action on thermocouple materials
- reduce measuring lag.
- increase the fidelity.
- increase the sensitivity.
Show the answer
Answer: A. guard against corrosive and oxidising action on thermocouple materials
Gas analysis in plants is commonly done with a
- thermal conductivity cell
- X-ray diffraction
- mass spectrometer
- emission spectrometer
Show the answer
Answer: A. thermal conductivity cell
A psychrometer measures the
- humidity of gases
- moisture content of solids
- water of crystallisation
- hygroscopic nature of solids
Show the answer
Answer: A. humidity of gases
In paper mills, moisture in the paper is continuously measured through its
- thermal conductivity through the paper
- electrical resistance through the paper
- magnetic susceptibility
- none of these
Show the answer
Answer: B. electrical resistance through the paper
A simple pitot tube measures the
- average velocity
- maximum velocity
- point velocity
- static pressure
Show the answer
Answer: C. point velocity
A Pirani gauge measures
- very high pressure.
- high vacuum.
- liquid level under pressure.
- liquid level at atmospheric pressure
Show the answer
Answer: B. high vacuum.
A barometer reads ____ pressure.
- absolute
- gauge
- absolute as well as gauge
- dynamic
Show the answer
Answer: A. absolute
The level of a liquid in a pressurised vessel can be measured with a
- bubbler system
- differential pressure manometer
- diaphragm box system
- air-trap system
Show the answer
Answer: B. differential pressure manometer
Specific gravity of a liquid can be measured continuously with a
- hydrometer
- contact-type electric indicators
- displacement meter
- both (a) and (c)
Show the answer
Answer: D. both (a) and (c)
A hot-wire anemometer measures
- flow rates of fluids.
- flow rates of granular solids.
- very high temperature.
- thermal conductivity of gases.
Show the answer
Answer: A. flow rates of fluids.
Flow through an orifice meter is ____ the pressure differential.
- proportional to
- inversely proportional to the square root of
- proportional to the square root of
- inversely proportional to the square of
Show the answer
Answer: C. proportional to the square root of
Which flowmeter is a variable-area meter?
- Venturimeter
- Rotameter
- Pitot tube
- Hot wire anemometer
Show the answer
Answer: B. Rotameter
In an exothermic reactor, the usual manipulated variable is the flow of
- coolant
- reactants
- product
- none of these
Show the answer
Answer: A. coolant
Adding integral action to proportional control
- elimination of offset
- reduction of offset
- reduction of stability time
- none of these
Show the answer
Answer: A. elimination of offset
Cascade control uses
- feed forward control.
- more than one feed-back loop.
- on-off control.
- one feed-back loop.
Show the answer
Answer: B. more than one feed-back loop.
Which controller gives the smallest maximum deviation?
- P-controller
- P-I controller
- P-I-D controller
- P-D controller
Show the answer
Answer: C. P-I-D controller
Pressure in an ammonia synthesis reactor is measured with a
- Bourdon gauge
- U-tube manometer
- Inclined tube manometer
- Pirani guage
Show the answer
Answer: A. Bourdon gauge
An absolute pressure of about 0.01 psi is measured with a ____ gauge.
- ionisation
- Pirani
- Mcloid
- none of these
Show the answer
Answer: B. Pirani
Continuous moisture measurement in paper uses a
- sling psychrometer.
- hair-hygrometer.
- weighing.
- high resistance Wheatstone's bridge circuit.
Show the answer
Answer: D. high resistance Wheatstone's bridge circuit.
An absolute pressure of about 0.0001 psi is measured with a ____ gauge.
- Mcloid
- Pirani
- thermocouple
- none of these
Show the answer
Answer: A. Mcloid
Thermocouple EMF is of the order of
- millivolts
- microvolts
- volts
- kilo volts
Show the answer
Answer: A. millivolts
Sub-zero Celsius temperatures in industry are most often measured with
- thermocouples
- resistance thermometers
- gas thermometers
- bi-metallic thermometers
Show the answer
Answer: B. resistance thermometers
An optical pyrometer is usable from about ____ °C upward.
- 800
- 400
- 1200
- 1500
Show the answer
Answer: A. 800
Which thermocouple suits about 1400 °C?
- Copper-constantan
- Aluminium-chromel
- Platinum-platinum+rhodium
- None of these
Show the answer
Answer: C. Platinum-platinum+rhodium
The interface level in a pressure vessel is measured with
- float
- manometers of float type
- U-tube manometer
- none of these
Show the answer
Answer: B. manometers of float type
Sludge flow is measured with a
- V-notch
- rectangular notch
- circular pipe
- Kennison nozzle
Show the answer
Answer: D. Kennison nozzle
The composition of natural gas is found with a
- chromatograph
- orsat apparatus
- spectrometer
- none of these
Show the answer
Answer: A. chromatograph
Instrument bellows are made of
- leather
- paper
- plastic
- thin copper sheet
Show the answer
Answer: D. thin copper sheet
A flapper–nozzle is the heart of a ____ controller.
- pneumatic
- hydraulic
- electronic
- none of these
Show the answer
Answer: A. pneumatic
A weir (diaphragm) valve is well suited to
- slurries
- acids
- neutral solutions
- bases
Show the answer
Answer: A. slurries
Fuel oil to a burner is commonly regulated with a ____ valve.
- gate
- butterfly
- rotary plug
- none of these
Show the answer
Answer: C. rotary plug
To send a control signal about one kilometre, the best mode is
- hydraulic
- pneumatic
- electronic
- none of these
Show the answer
Answer: C. electronic
A pilot relay in pneumatic transmission is used to
- speed up the signal.
- change the flow of air.
- adjust the signal.
- none of these.
Show the answer
Answer: B. change the flow of air.
Phase margin equals
- 180° - phase lag
- phase lag - 180°
- phase lag + 180°
- phase lag + 90°
Show the answer
Answer: A. 180° - phase lag
The Bode stability method works with the ____ loop transfer function.
- open
- closed
- either (a) or (b)
- neither (a) nor (b)
Show the answer
Answer: A. open
The Routh test is applied to the ____ loop characteristic equation.
- open
- closed
- either (a) or (b)
- neither (a) nor (b)
Show the answer
Answer: B. closed
A Nichols chart relates
- A.R. vs. phase lag of first order.
- A.R. vs. phase lag of second order.
- closed loop values vs. open loop values.
- frequency response values of controllers.
Show the answer
Answer: C. closed loop values vs. open loop values.
Hydraulic controllers use ____ as the working fluid.
- water
- steam
- air
- oil
Show the answer
Answer: D. oil
Which controller leaves the largest offset?
- P-controller
- P-I controller
- P-D controller
- P-I-D controller
Show the answer
Answer: A. P-controller
The degrees of freedom of a process give ____ number of controllers that can be installed.
- the maximum
- the minimum
- both maximum and the minimum
- nothing about the
Show the answer
Answer: A. the maximum
Gain margin equals the
- amplitude ratio
- reciprocal of amplitude ratio
- gain in P controller
- gain in P-I controller
Show the answer
Answer: B. reciprocal of amplitude ratio
A tiny freezing-point depression caused by a dissolved solute is best measured with a
- Beckman thermometer
- dilatometer
- mercury thermometer
- bimetallic thermometer
Show the answer
Answer: A. Beckman thermometer
A control system that uses feedback from output is called:
- Cascade control
- Open-loop control
- Feed-forward control
- Closed-loop control
Show the answer
Answer: D. Closed-loop control Closed-loop (feedback) control
An open-loop control system:
- Self-corrects errors
- More accurate than closed-loop
- Uses output feedback
- Has no feedback from output
Show the answer
Answer: D. Has no feedback from output
The difference between setpoint and measured value is called:
- Error
- Gain
- Integral
- Offset
Show the answer
Answer: A. Error Error (deviation)
PID stands for:
- None
- Proportional Integral Design
- Proportional Integral Derivative
- Process Instrument Diagram
Show the answer
Answer: C. Proportional Integral Derivative
The proportional controller output = Kc × e. What is Kc?
- Derivative time
- Controller gain
- Bias
- Integral time
Show the answer
Answer: B. Controller gain Controller gain (proportional gain)
Integral action in a PID controller eliminates:
- Oscillations
- Steady-state offset
- Overshoot
- Dead time
Show the answer
Answer: B. Steady-state offset Steady-state offset (bias)
Derivative action in a PID controller:
- Increases offset
- Predicts error trend and reduces overshoot
- Eliminates steady-state error
- Reduces gain
Show the answer
Answer: B. Predicts error trend and reduces overshoot
Transfer function is defined as:
- Ratio of Laplace transform of output to input
- Frequency ratio
- Time domain ratio
- None
Show the answer
Answer: A. Ratio of Laplace transform of output to input Ratio of Laplace transform of output to input (with zero initial conditions)
A first-order system transfer function G(s) = K/(τs+1). τ is:
- Dead time
- Natural frequency
- Time constant
- Gain
Show the answer
Answer: C. Time constant Time constant (time to reach 63.2% of final value)
A second-order underdamped system shows:
- Monotonic approach
- Oscillatory response with overshoot
- No overshoot
- Unstable response always
Show the answer
Answer: B. Oscillatory response with overshoot
Damping ratio ζ = 1 gives:
- Critically damped response
- Underdamped
- Unstable
- Overdamped
Show the answer
Answer: A. Critically damped response Critically damped response (fastest without oscillation)
The Bode plot shows:
- Time response
- Poles and zeros
- Step response
- Magnitude and phase vs. frequency
Show the answer
Answer: D. Magnitude and phase vs. frequency
Gain margin is the factor by which gain can be increased before:
- System becomes unstable
- Steady-state error appears
- Overshoot increases
- Oscillations start
Show the answer
Answer: A. System becomes unstable
Phase margin is the additional phase lag before:
- Gain becomes 0 dB
- None
- Steady state is reached
- System becomes unstable
Show the answer
Answer: D. System becomes unstable System becomes unstable (phase reaches -180°)
The Nyquist stability criterion is based on:
- The number of encirclements of -1 on Nyquist plot
- Root locus
- Routh array
- Bode plot
Show the answer
Answer: A. The number of encirclements of -1 on Nyquist plot
Routh-Hurwitz criterion determines stability by:
- Signs of elements in first column of Routh array
- Bode plot
- Frequency response
- Poles location
Show the answer
Answer: A. Signs of elements in first column of Routh array
A system is stable if all poles are in:
- Origin
- Imaginary axis
- Right-half
- Left-half of s-plane
Show the answer
Answer: D. Left-half of s-plane Left-half of s-plane (negative real part)
Root locus shows how closed-loop poles move as:
- Time varies
- Gain K varies from 0 to infinity
- Frequency varies
- Input varies
Show the answer
Answer: B. Gain K varies from 0 to infinity
Ziegler-Nichols tuning method uses:
- Mathematical model only
- Ultimate gain Ku and ultimate period Pu found experimentally
- Step response
- Frequency sweep
Show the answer
Answer: B. Ultimate gain Ku and ultimate period Pu found experimentally
A process with long dead time is:
- No effect on control
- Easiest to control
- Difficult to control needs detuned controller or Smith predictor
- Same as first-order
Show the answer
Answer: C. Difficult to control needs detuned controller or Smith predictor
Cascade control improves performance by:
- Reducing gain
- Inner fast loop rejecting disturbances before they affect outer loop
- Adding more sensors
- Eliminating integral
Show the answer
Answer: B. Inner fast loop rejecting disturbances before they affect outer loop
Feed-forward control corrects for disturbances:
- Without measurement
- Before they affect the process
- After they affect process
- None
Show the answer
Answer: B. Before they affect the process Before they affect the process (requires disturbance measurement)
Smith predictor is used for:
- Batch processes
- Non-linear processes
- Processes with large dead time to compensate delay in feedback
- Fast processes
Show the answer
Answer: C. Processes with large dead time to compensate delay in feedback
Model Predictive Control (MPC):
- Only uses current error
- Optimizes control actions over a future horizon using process model
- Same as PID
- Requires no model
Show the answer
Answer: B. Optimizes control actions over a future horizon using process model
The process gain Kp = change in output / change in input at:
- Steady state
- Time constant
- Zero
- Peak
Show the answer
Answer: A. Steady state
First-order plus dead time (FOPDT) model has:
- Two parameters
- Three parameters
- One parameter
- Four parameters
Show the answer
Answer: B. Three parameters Three parameters: gain K, time constant τ, dead time θ
Integral windup occurs when:
- Derivative is too large
- Controller output saturates while integral accumulates excessive error
- Gain is too low
- Process is nonlinear
Show the answer
Answer: B. Controller output saturates while integral accumulates excessive error
Anti-reset windup prevents:
- Steady-state offset
- Overshoot
- Excessive integral buildup during output saturation
- Oscillation
Show the answer
Answer: C. Excessive integral buildup during output saturation
A P-only controller has offset because:
- Process has dead time
- Finite proportional gain cannot drive error to zero at steady state
- Gain is too high
- It lacks derivative
Show the answer
Answer: B. Finite proportional gain cannot drive error to zero at steady state
The offset in P-only control is eliminated by adding:
- Integral action
- Derivative action
- Dead time compensation
- More gain
Show the answer
Answer: A. Integral action Integral (I) action
For a pure integrating process G(s) = K/s, a P-only controller gives:
- Large offset
- Instability always
- No steady-state offset
- Oscillations always
Show the answer
Answer: C. No steady-state offset No steady-state offset (process already integrates)
Split-range control uses one controller to drive:
- Only one valve
- No valves
- Multiple controllers
- Two or more valves over different ranges
Show the answer
Answer: D. Two or more valves over different ranges
Ratio control maintains the ratio between:
- Two process streams
- Two controllers
- Setpoint and output
- None
Show the answer
Answer: A. Two process streams Two process streams (e.g., fuel to air)
Feedforward with feedback combination:
- Feedforward handles measured disturbances, feedback corrects residual errors
- Not possible
- Only feedforward
- Only feedback
Show the answer
Answer: A. Feedforward handles measured disturbances, feedback corrects residual errors
Process variable (PV) in a control loop is:
- The disturbance
- The manipulated variable
- The measured output being controlled
- The setpoint
Show the answer
Answer: C. The measured output being controlled
Manipulated variable (MV) in a control loop is:
- The input adjusted by controller
- The measured output
- The setpoint
- The disturbance
Show the answer
Answer: A. The input adjusted by controller The input adjusted by controller (e.g., valve position)
Controlled variable is:
- The controller output
- The manipulated input
- The process output maintained at setpoint
- The error signal
Show the answer
Answer: C. The process output maintained at setpoint
For a heat exchanger temperature control, typical manipulated variable:
- Feed composition
- Process pressure
- Cooling/heating medium flow rate
- Feed temperature directly
Show the answer
Answer: C. Cooling/heating medium flow rate
A control valve with equal percentage characteristic:
- Used for level only
- Constant gain
- Decreasing gain
- Gain proportional to valve position
Show the answer
Answer: D. Gain proportional to valve position Gain proportional to valve position - good for pressure-dominated processes
Valve positioner is used to:
- Reduce pressure
- Control temperature
- Ensure valve reaches commanded position reducing hysteresis and friction
- Measure flow
Show the answer
Answer: C. Ensure valve reaches commanded position reducing hysteresis and friction
Level control in a tank often uses:
- PI or PID always
- Only differential pressure
- Only ultrasonic level
- P-only or PD control
Show the answer
Answer: D. P-only or PD control P-only or PD control (integral not needed for averaging level)
Pressure control in a gas system is typically:
- Requires derivative
- Same as level
- Fast response
- Very slow response
Show the answer
Answer: C. Fast response Fast response - P or PI controller sufficient
Flow control loop is characterized by:
- Long dead time typically
- Fast dynamics
- Slow dynamics
- Requires derivative
Show the answer
Answer: B. Fast dynamics Fast dynamics - high gain PI controller used
Temperature control loops are typically:
- Same as pressure
- Fast like flow
- Slow with dead time
- Requires cascade always
Show the answer
Answer: C. Slow with dead time Slow with dead time - PID with derivative action commonly used
Composition control (e.g., by GC analyser) has:
- Long dead time due to analyser cycle
- Fast response
- No dead time
- Simple P-only
Show the answer
Answer: A. Long dead time due to analyser cycle Long dead time due to analyser cycle - requires detuned controller or predictor
DCS (Distributed Control System) is:
- Computer-based control system with controllers distributed throughout plant
- Standalone controllers only
- Single central computer
- Manual panel only
Show the answer
Answer: A. Computer-based control system with controllers distributed throughout plant
PLC (Programmable Logic Controller) is primarily used for:
- High-level optimization
- Continuous PID control
- Sequential logic, on/off discrete control
- Analogue signals only
Show the answer
Answer: C. Sequential logic, on/off discrete control
SCADA stands for:
- Supervisory Control and Data Acquisition
- None
- System Control and Data Analysis
- Supervisory Computer Automated Design
Show the answer
Answer: A. Supervisory Control and Data Acquisition
ISA-5.1 standard covers:
- Instrumentation symbols and identification on P&IDs
- Pipe specifications
- Pressure vessel design
- Electrical standards
Show the answer
Answer: A. Instrumentation symbols and identification on P&IDs
A P&ID is a:
- Process Flow Diagram
- Electrical diagram
- Physical layout drawing
- Piping and Instrumentation Diagram showing all instruments and control loops
Show the answer
Answer: D. Piping and Instrumentation Diagram showing all instruments and control loops
The tag FIC-101 on a P&ID means:
- None
- Flow Indicating Controller loop 101
- Flow Isolation Check
- Filter Inlet Connector
Show the answer
Answer: B. Flow Indicating Controller loop 101
A transmitter converts:
- Process variable to standard signal
- Flow to temperature
- Setpoint to output
- Control signal to valve position
Show the answer
Answer: A. Process variable to standard signal Process variable to standard signal (4-20 mA or digital)
4-20 mA signal: 4 mA represents:
- 0% with live zero for wire-break detection
- 100%
- 50%
- Negative values
Show the answer
Answer: A. 0% with live zero for wire-break detection 0% (zero) with live zero for wire-break detection
HART protocol:
- Only for pH
- Superimposes digital signal on 4-20 mA loop for two-way communication
- Replaces 4-20 mA
- Only for wireless
Show the answer
Answer: B. Superimposes digital signal on 4-20 mA loop for two-way communication
Fieldbus technology:
- Wireless only
- Analogue communication
- Digital communication replacing 4-20 mA point-to-point wiring
- Only for gas detectors
Show the answer
Answer: C. Digital communication replacing 4-20 mA point-to-point wiring
A final control element is:
- The controller
- The sensor
- The transmitter
- The device that directly changes process variable
Show the answer
Answer: D. The device that directly changes process variable The device that directly changes process variable (e.g., valve, motor)
Control valve sizing coefficient Cv is defined by:
- Valve diameter
- Stem travel
- Actuator size
- Flow rate through valve at unit pressure drop for water
Show the answer
Answer: D. Flow rate through valve at unit pressure drop for water
Fail-safe position of control valve is chosen based on:
- None
- Cost of valve
- Process safety on loss of air/power
- Operator preference
Show the answer
Answer: C. Process safety on loss of air/power Process safety on loss of air/power (e.g., fail-closed for fuel)
A safety instrumented system (SIS) must be:
- Optional
- Part of BPCS
- Same as BPCS
- Independent of the basic process control system
Show the answer
Answer: D. Independent of the basic process control system Independent of the basic process control system (BPCS)
SIL (Safety Integrity Level) SIL 2 means probability of failure on demand (PFD) between:
- 10⁻² and 10⁻³
- 10⁻¹ and 10⁻²
- 10⁰ and 10⁻¹
- 10⁻³ and 10⁻⁴
Show the answer
Answer: A. 10⁻² and 10⁻³
Overshoot in a control system is:
- Rise time
- Response delay
- Percentage by which response exceeds setpoint before settling
- Steady-state error
Show the answer
Answer: C. Percentage by which response exceeds setpoint before settling
Rise time is:
- Dead time
- Time to settle
- Time to reach setpoint
- Time for response to rise from 10% to 90% of final value
Show the answer
Answer: D. Time for response to rise from 10% to 90% of final value
Settling time is:
- Peak time
- Time for response to stay within ±5% of final value
- Rise time
- Time to first reach setpoint
Show the answer
Answer: B. Time for response to stay within ±5% of final value Time for response to stay within ±5% (or ±2%) of final value
Dead time (transport delay) in a process is due to:
- None
- Plug flow transport delay, analyser cycle time, sensor lag
- Valve friction
- Controller processing time
Show the answer
Answer: B. Plug flow transport delay, analyser cycle time, sensor lag
Internal Model Control (IMC) parameter λ represents:
- Controller gain
- Dead time
- Process gain
- Desired closed-loop response speed
Show the answer
Answer: D. Desired closed-loop response speed Desired closed-loop response speed - larger λ = slower safer control
Inverse response (non-minimum phase) occurs in processes where:
- None
- Response is monotonic
- Initial response is opposite to final direction
- Dead time is large
Show the answer
Answer: C. Initial response is opposite to final direction Initial response is opposite to final direction (e.g., boiler drum level on increased firing)
The relative gain array (RGA) helps in:
- Tuning PID
- Stability analysis
- Single-loop design
- Pairing inputs and outputs in multivariable control systems
Show the answer
Answer: D. Pairing inputs and outputs in multivariable control systems
Decoupling in multivariable control aims to:
- Add more sensors
- Increase gain
- Reduce integral
- Eliminate or reduce interactions between control loops
Show the answer
Answer: D. Eliminate or reduce interactions between control loops
Adaptive control changes controller parameters based on:
- Only setpoint changes
- Changes in process dynamics over time
- Fixed model
- Disturbances only
Show the answer
Answer: B. Changes in process dynamics over time
Gain scheduling is a form of adaptive control where:
- Controller parameters are pre-set at different operating conditions
- Parameters self-adjust
- None
- Only gain changes
Show the answer
Answer: A. Controller parameters are pre-set at different operating conditions
Nonlinear control is needed when:
- Only batch processes
- Only temperature
- All processes
- Process exhibits significant nonlinearity that linear controllers cannot handle
Show the answer
Answer: D. Process exhibits significant nonlinearity that linear controllers cannot handle
Linearization of nonlinear process is done around:
- The setpoint only
- The maximum
- An operating point for use with linear controller design
- The minimum
Show the answer
Answer: C. An operating point for use with linear controller design An operating point (steady state) for use with linear controller design
For a process gain that varies with operating point, the product Kp × Kc should be:
- Roughly constant
- Always large
- = 1
- Always small
Show the answer
Answer: A. Roughly constant Roughly constant (compensate by adjusting Kc when Kp changes)
Frequency response methods (Bode Nyquist) determine:
- Transient response
- Step response only
- Stability margins and frequency-domain performance
- Time domain only
Show the answer
Answer: C. Stability margins and frequency-domain performance
The crossover frequency ωc is where:
- Phase = -180°
- Gain is minimum
- Gain is maximum
- Open-loop magnitude = 1 used to determine phase margin
Show the answer
Answer: D. Open-loop magnitude = 1 used to determine phase margin Open-loop magnitude = 1 (0 dB) used to determine phase margin
The phase crossover frequency ωpc is where:
- System oscillates
- Response peaks
- Magnitude = 0 dB
- Open-loop phase = -180° used to determine gain margin
Show the answer
Answer: D. Open-loop phase = -180° used to determine gain margin
A controller with Kc = 0 is:
- Maximum control
- Derivative only
- Integral only
- No control action
Show the answer
Answer: D. No control action No control action (manual or open-loop)
Derivative on measurement (vs derivative on error) avoids:
- Derivative kick when setpoint is stepped
- Steady-state offset
- Integral windup
- Oscillations
Show the answer
Answer: A. Derivative kick when setpoint is stepped
Setpoint weighting in PID reduces:
- Integral windup
- Overshoot on setpoint changes while maintaining disturbance rejection
- Steady-state error
- Dead time effect
Show the answer
Answer: B. Overshoot on setpoint changes while maintaining disturbance rejection
An interacting PID (series form) vs non-interacting (parallel/ideal):
- Both are common
- Interacting always better
- Non-interacting not used
- They are identical
Show the answer
Answer: A. Both are common Both are common - interacting couples I and D adjustments
The Cohen-Coon tuning rules are based on:
- Frequency sweep
- Open-loop process reaction curve
- Closed-loop oscillation test
- Simulation only
Show the answer
Answer: B. Open-loop process reaction curve Open-loop process reaction curve (step test identifying K, τ, θ)
Lambda (λ) tuning method sets:
- Closed-loop time constant λ as single tuning parameter
- Integral time directly
- Derivative time directly
- Ultimate period
Show the answer
Answer: A. Closed-loop time constant λ as single tuning parameter Closed-loop time constant λ as single tuning parameter - IMC-based PID
On-off (bang-bang) control is simplest but causes:
- Perfect control
- Continuous cycling around setpoint
- Steady-state offset
- No overshoot
Show the answer
Answer: B. Continuous cycling around setpoint Continuous cycling around setpoint (hunting)
Hysteresis (dead band) in on-off control:
- Has no effect
- Reduces cycling frequency at expense of larger offset deviation
- Increases cycling
- Eliminates offset
Show the answer
Answer: B. Reduces cycling frequency at expense of larger offset deviation
Inferential control estimates controlled variable from:
- Direct measurement
- Easier-measured secondary variable
- Setpoint only
- Simulation only
Show the answer
Answer: B. Easier-measured secondary variable Easier-measured secondary variable (e.g., tray temperature infers composition)
Statistical Process Control (SPC) monitors process using:
- Control charts to detect special causes
- PID control
- Manual inspection
- Advanced algorithms
Show the answer
Answer: A. Control charts to detect special causes Control charts (Shewhart charts) to detect special causes
A UCL/LCL in a control chart represents:
- Upper/Lower control limits
- Specification limits
- Alarm limits
- Safety limits
Show the answer
Answer: A. Upper/Lower control limits Upper/Lower control limits (typically ±3σ from mean)
Process capability index Cp = (USL - LSL) / (6σ). Cp > 1.33 means:
- Cp has no meaning
- Process is capable
- Process is marginally capable
- Process is not capable
Show the answer
Answer: B. Process is capable Process is capable - can meet specifications
Real-time optimization (RTO) operates:
- At supervisory level above MPC adjusting setpoints for economic optimum
- Same level as PID
- Below PID
- Only offline
Show the answer
Answer: A. At supervisory level above MPC adjusting setpoints for economic optimum
The control hierarchy from bottom to top is:
- RTO → MPC → PID
- PID → RTO → MPC
- PID → Advanced control → RTO → Business planning
- All at same level
Show the answer
Answer: C. PID → Advanced control → RTO → Business planning PID → Advanced control (MPC) → RTO → Business planning
A two-degrees-of-freedom (2DOF) controller separates:
- Setpoint tracking and disturbance rejection performance tuning
- Feedback and feedforward
- Single parameter tuning
- None
Show the answer
Answer: A. Setpoint tracking and disturbance rejection performance tuning
An analyser (online GC or NIR) in a control loop has:
- No dead time
- Large dead time equal to analyser cycle time
- Only for laboratory
- Instant response
Show the answer
Answer: B. Large dead time equal to analyser cycle time Large dead time equal to analyser cycle time (minutes)
The output bias in PID controller equals the steady-state output when:
- Error = 0 at operating point
- Setpoint = 0
- Error = 1
- Controller is manual
Show the answer
Answer: A. Error = 0 at operating point Error = 0 at operating point (integral sets this in I-containing controller)
Auto-tuning in modern controllers performs:
- Closed-loop relay test or step test to automatically identify process parameters
- Manual tuning only
- Tuning once at startup only
- No tuning
Show the answer
Answer: A. Closed-loop relay test or step test to automatically identify process parameters
P&ID stands for:
- Piping and Instrumentation Diagram
- Process and Instrument Drawing
- Piping and Instrument Design
- Plant and Instrument Diagram
Show the answer
Answer: A. Piping and Instrumentation Diagram
A PFD primarily shows:
- All piping sizes and schedules
- Electrical connections
- Instrument details
- Major equipment and process streams
Show the answer
Answer: D. Major equipment and process streams
ISA 5.1 standard governs:
- Instrumentation symbols and identification
- Equipment drawing standards
- Piping schedules
- Weld symbols
Show the answer
Answer: A. Instrumentation symbols and identification
FIC on a P&ID tag means:
- Feed Inlet Connection
- Flow Input Computer
- Flow Indicating Controller
- Flow Instrument Connection
Show the answer
Answer: C. Flow Indicating Controller
A sectional view reveals:
- Electrical layout
- External dimensions
- Piping layout
- Interior details of an object
Show the answer
Answer: D. Interior details of an object
First-angle projection is standard in:
- Australia
- Europe and Asia
- USA
- Canada
Show the answer
Answer: B. Europe and Asia
Third-angle projection is standard in:
- USA and Canada
- Europe
- Asia
- South America
Show the answer
Answer: A. USA and Canada
A hidden line on a drawing is shown as:
- Solid thin line
- Solid thick line
- Dashed line
- Chain line
Show the answer
Answer: C. Dashed line
Centre lines on drawings are shown as:
- Dotted lines
- Alternating long and short dashes
- Solid thin lines
- Dashed lines
Show the answer
Answer: B. Alternating long and short dashes
Schedule number of a pipe indicates:
- Wall thickness
- Flange rating
- Pipe material
- Nominal bore
Show the answer
Answer: A. Wall thickness
Nominal pipe size (NPS) refers to:
- Pipe weight per metre
- Wall thickness
- Exact outer diameter
- An approximate inner diameter designation
Show the answer
Answer: D. An approximate inner diameter designation
A centrifugal pump in P&ID typically shows:
- Circle with two lines
- Rectangle with inlet/outlet
- Triangle pointing upward
- Circle with an arrow indicating impeller
Show the answer
Answer: D. Circle with an arrow indicating impeller
Elevation drawing is a view from:
- Top
- Bottom
- Side
- Isometric angle
Show the answer
Answer: C. Side Side (front or rear)
Plan drawing is a view from:
- Front
- Top
- Side
- Cross-section
Show the answer
Answer: B. Top Top (overhead)
Equipment datasheet contains:
- Cost estimate
- Drawing number only
- Instrument tags
- Design conditions, materials, and performance data
Show the answer
Answer: D. Design conditions, materials, and performance data
PSV (Pressure Safety Valve) symbol shows:
- Spring-loaded valve with set point
- Control valve
- Check valve
- Globe valve symbol
Show the answer
Answer: A. Spring-loaded valve with set point
A globe valve symbol in P&ID looks like:
- Bowtie or figure-8
- Square on line
- Diamond
- Circle
Show the answer
Answer: A. Bowtie or figure-8
Ball valve symbol in P&ID:
- Triangle
- Circle with a bar
- Rectangle
- Diamond
Show the answer
Answer: B. Circle with a bar Circle with a bar (handle)
Gate valve symbol:
- Circle with a line
- Arrow
- Square
- Bowtie/hourglass shape
Show the answer
Answer: D. Bowtie/hourglass shape
A check valve symbol shows:
- Arrow indicating allowed flow direction
- Circle
- Square
- Bowtie
Show the answer
Answer: A. Arrow indicating allowed flow direction
Spectacle blind symbol shows:
- Triangle
- Square on line
- Two circles on pipe
- Single circle
Show the answer
Answer: C. Two circles on pipe Two circles (one solid, one outline) on pipe
Electrical signal line (4-20 mA) is shown as:
- Dotted
- Solid line with label
- Chain line
- Dashed
Show the answer
Answer: B. Solid line with label
Pneumatic signal line on P&ID:
- Dotted line
- Solid line
- Dashed line
- Chain line
Show the answer
Answer: C. Dashed line
A fired heater on PFD is shown as:
- Triangle
- Simple rectangle
- Rectangle with flame symbol inside
- Circle
Show the answer
Answer: C. Rectangle with flame symbol inside
A storage tank (fixed roof) on P&ID:
- Circle
- Diamond
- Rectangle
- Cylinder symbol with flat top
Show the answer
Answer: D. Cylinder symbol with flat top
A pressure vessel (vertical) symbol:
- Triangle
- Rectangle
- Circle
- Vertical cylinder with domed ends
Show the answer
Answer: D. Vertical cylinder with domed ends
A compressor on P&ID is shown as:
- Circle only
- Triangle or circle with arrow indicating rotation
- Diamond
- Rectangle
Show the answer
Answer: B. Triangle or circle with arrow indicating rotation
Battery limit on drawings is shown as:
- None
- Solid thick line
- Dashed or chain line across the drawing
- Dotted line
Show the answer
Answer: C. Dashed or chain line across the drawing
North arrow on plot plan indicates:
- None
- Process flow direction
- True or magnetic north direction for orientation
- Wind direction
Show the answer
Answer: C. True or magnetic north direction for orientation
Line number typically encodes:
- Only fluid service
- Only material
- Fluid service, line size, spec, insulation, sequence number
- Only pipe size
Show the answer
Answer: C. Fluid service, line size, spec, insulation, sequence number
As-built drawings reflect:
- Design intent only
- Actual installed configuration after construction
- Vendor data
- None
Show the answer
Answer: B. Actual installed configuration after construction
Red-lining drawings means:
- Marking up physical changes in red pen for as-built updates
- Error marking
- Drawing with red ink
- None
Show the answer
Answer: A. Marking up physical changes in red pen for as-built updates
Weld map marks:
- None
- Instrument tags
- Drawing number only
- Location and type of each weld for inspection and traceability
Show the answer
Answer: D. Location and type of each weld for inspection and traceability
Clash detection in 3D model helps to:
- None
- Identify physical interference between pipes, equipment, structures
- Draw P&IDs
- Calculate process flows
Show the answer
Answer: B. Identify physical interference between pipes, equipment, structures
Drawing scale 1:10 means:
- Object is drawn 10 times smaller than actual
- Arbitrary scale
- Object is 10 times larger
- Full size
Show the answer
Answer: A. Object is drawn 10 times smaller than actual
NTS on drawing means:
- None
- New Tee Section
- Next To Seam
- Not To Scale
Show the answer
Answer: D. Not To Scale
Rupture disc symbol on P&ID:
- Square
- Circle on a line
- Triangle on a line
- Diamond shape on a line
Show the answer
Answer: D. Diamond shape on a line
A detail drawing shows:
- P&ID
- Overall layout
- Entire plant
- Enlarged view of a specific part or connection
Show the answer
Answer: D. Enlarged view of a specific part or connection
3D plant design software examples:
- PDMS, SmartPlant, Intergraph
- Manual drafting
- None
- AutoCAD 2D only
Show the answer
Answer: A. PDMS, SmartPlant, Intergraph
Hazardous area classification is shown on:
- PFD
- Area classification drawing with zone boundaries
- P&ID
- None
Show the answer
Answer: B. Area classification drawing with zone boundaries
Equipment number format typically:
- Alphabetical only
- Numeric only
- Random numbers
- Type code + unit number + sequence
Show the answer
Answer: D. Type code + unit number + sequence Type code + unit number + sequence (e.g. E-101)
SIS on P&ID has:
- Only in text notes
- No distinction
- Separate dedicated symbols and SIL tagging
- Same symbols as basic controls
Show the answer
Answer: C. Separate dedicated symbols and SIL tagging
A Y-strainer symbol shows:
- Circle
- Arrow
- T-junction
- Y-shaped fitting on line
Show the answer
Answer: D. Y-shaped fitting on line
Underground piping on drawings:
- Thick solid lines
- Dashed or dotted lines
- Solid lines
- Chain lines
Show the answer
Answer: B. Dashed or dotted lines
Heat tracing on pipe in P&ID:
- Zigzag line alongside pipe
- Dashed line
- Dotted line
- Solid line
Show the answer
Answer: A. Zigzag line alongside pipe
A flame arrestor on P&ID:
- Two parallel plates symbol on line
- None
- Single valve symbol
- Circle
Show the answer
Answer: A. Two parallel plates symbol on line
Drawing revision control - latest revision:
- Color coding
- Letter or number in revision column with date and description
- No marking
- Symbol
Show the answer
Answer: B. Letter or number in revision column with date and description
Pipe support symbols include:
- Instrument symbols
- U-bolt, hanger, spring support symbols
- None
- Valve symbols
Show the answer
Answer: B. U-bolt, hanger, spring support symbols
Tie-in point on P&ID shows:
- Open pipe end
- Valve
- None
- Future connection point, often stub end with blind flange
Show the answer
Answer: D. Future connection point, often stub end with blind flange
Fabrication drawing for pressure vessel includes:
- Weld details, nozzle schedule, material list, dimensions
- P&ID connections only
- None
- Process conditions only
Show the answer
Answer: A. Weld details, nozzle schedule, material list, dimensions
DWG NO on title block means:
- Dimension without guide
- Drawing number
- None
- Design working group
Show the answer
Answer: B. Drawing number
Isometric piping drawing is used for:
- None
- Fabrication of piping spools showing exact routing in 3D
- Only layout planning
- P&ID only
Show the answer
Answer: B. Fabrication of piping spools showing exact routing in 3D
A line continuation symbol on P&ID:
- End of pipe
- Valve
- None
- Arrow with sheet/drawing number where line continues
Show the answer
Answer: D. Arrow with sheet/drawing number where line continues
Vendor data package (VDP) includes:
- Only drawings
- None
- Equipment drawings, datasheets, certificates, manuals supplied by equipment vendor
- Only certificates
Show the answer
Answer: C. Equipment drawings, datasheets, certificates, manuals supplied by equipment vendor
The 'as-built' P&ID reflects:
- Design intent only
- All changes made during construction and commissioning
- Vendor data
- None
Show the answer
Answer: B. All changes made during construction and commissioning
A functional specification describes:
- Material of construction
- Physical dimensions
- What an instrument or system must do
- None
Show the answer
Answer: C. What an instrument or system must do What an instrument or system must do (not how it does it)
IFC (Issued for Construction) drawings:
- Draft drawings
- Conceptual drawings
- None
- Final approved drawings used for actual construction
Show the answer
Answer: D. Final approved drawings used for actual construction
IFR (Issued for Review) drawings:
- Construction drawings
- None
- Approved drawings
- Drawings sent to client/discipline for comments before finalisation
Show the answer
Answer: D. Drawings sent to client/discipline for comments before finalisation
Hook-up drawing shows:
- Instrument installation details
- General arrangement
- None
- P&ID
Show the answer
Answer: A. Instrument installation details Instrument installation details - tubing, fittings, valves connections to instrument
Instrument index (register):
- None
- Material list
- List of all instruments with tag, type, range, set point, P&ID reference
- Drawing list
Show the answer
Answer: C. List of all instruments with tag, type, range, set point, P&ID reference
Plot plan scale typically:
- 1:10
- None
- 1:200 or 1:500 for large plants
- 1:1
Show the answer
Answer: C. 1:200 or 1:500 for large plants
Piping flexibility analysis checks:
- None
- Pressure drop only
- Flow rate
- Thermal expansion stresses in piping to prevent over-stress or flange leaks
Show the answer
Answer: D. Thermal expansion stresses in piping to prevent over-stress or flange leaks
Caesar II is a software for:
- P&ID drawing
- 3D modelling
- Piping stress analysis
- None
Show the answer
Answer: C. Piping stress analysis
Datasheet for centrifugal pump includes:
- Only flow
- None
- Only head
- Flow, head, NPSH, efficiency, shaft power, driver type, material, flange rating
Show the answer
Answer: D. Flow, head, NPSH, efficiency, shaft power, driver type, material, flange rating
P&ID revision cloud:
- Only title block change
- Full redraw
- None
- Cloud-shaped marking around changed area to highlight revision clearly
Show the answer
Answer: D. Cloud-shaped marking around changed area to highlight revision clearly
North arrow importance on plot plan:
- Decorative only
- Wind direction
- Gives orientation reference for all equipment coordinates and pipe routing
- None
Show the answer
Answer: C. Gives orientation reference for all equipment coordinates and pipe routing
Instrument line - capillary tubing on P&ID:
- Dotted line
- Shown as dashed line with notation for filled system
- None
- Solid line
Show the answer
Answer: B. Shown as dashed line with notation for filled system Shown as dashed line with notation for filled system (temperature element)
Category of drawing for FEED (Front-End Engineering Design):
- Preliminary P&IDs, PFDs, plot plans for cost estimation and basic design
- None
- Detailed fabrication drawings
- As-built drawings
Show the answer
Answer: A. Preliminary P&IDs, PFDs, plot plans for cost estimation and basic design
EPC contract:
- Engineering, Procurement, and Construction
- None
- Only procurement
- Only engineering
Show the answer
Answer: A. Engineering, Procurement, and Construction Engineering, Procurement, and Construction - one contractor delivers complete plant
EPCC contract adds:
- Only construction
- Only engineering
- None
- Commissioning to EPC scope
Show the answer
Answer: D. Commissioning to EPC scope Commissioning (C) to EPC scope
CFD (Computational Fluid Dynamics) in piping:
- Only 1D analysis
- Only pressure drop
- None
- Analyses complex flow patterns, pressure drops, mixing in 3D models
Show the answer
Answer: D. Analyses complex flow patterns, pressure drops, mixing in 3D models
Open/closed loop control on P&ID:
- Both same
- Closed loop
- None
- Open loop has sensor
Show the answer
Answer: B. Closed loop Closed loop: sensor → controller → final element; open loop: manual set point or direct action
Cascade control on P&ID:
- None
- Single loop only
- Secondary loop controlled by output of primary loop
- Feedforward only
Show the answer
Answer: C. Secondary loop controlled by output of primary loop Secondary (inner) loop controlled by output of primary (outer) loop - e.g. flow setpoint set by level controller
Ratio control:
- Feedforward
- Maintains fixed ratio between two flows
- None
- Cascade control
Show the answer
Answer: B. Maintains fixed ratio between two flows Maintains fixed ratio between two flows (e.g. fuel:air ratio) - ratio controller symbol on P&ID
Feedforward control on P&ID:
- Feedback only
- Measures disturbance and corrects before it upsets the process
- None
- Ratio control
Show the answer
Answer: B. Measures disturbance and corrects before it upsets the process Measures disturbance and corrects before it upsets the process - triangle/FF notation
Override (select) control:
- Ratio
- None
- Cascade
- High select or low select of two signals
Show the answer
Answer: D. High select or low select of two signals High select or low select of two signals - limits output variable (HS/LS symbol)
DCS tag numbering convention:
- <Measured variable><Function><Loop number> e.g. FIC-101 = Flow Indicating Controller loop 101
- Only numbers
- None
- Random
Show the answer
Answer: A. <Measured variable><Function><Loop number> e.g. FIC-101 = Flow Indicating Controller loop 101
Control valve fail position:
- None
- Always fail open
- Always fail closed
- FC = fail closed; FO = fail open
Show the answer
Answer: D. FC = fail closed; FO = fail open FC = fail closed; FO = fail open - defined for safety on loss of air/signal
Globe valve trim:
- V-port, equal percentage, linear, quick-opening
- Only ball valve
- None
- Not applicable
Show the answer
Answer: A. V-port, equal percentage, linear, quick-opening V-port, equal percentage, linear, quick-opening - determines installed characteristic
Cv of control valve:
- None
- Flow coefficient
- Kv
- No sizing needed
Show the answer
Answer: B. Flow coefficient Flow coefficient - US gal/min of water at 1 psi ΔP - sizes valve
Smart (SMART) transmitter on P&ID:
- Digital transmitter with HART or fieldbus communication
- None
- Analogue only
- No difference shown
Show the answer
Answer: A. Digital transmitter with HART or fieldbus communication Digital transmitter with HART or fieldbus communication - square or hexagonal bubble
Instrument air supply on P&ID:
- Hydraulic
- Shown as dashed line from IA header or noted as utility at instrument connections
- Electrical signal
- None
Show the answer
Answer: B. Shown as dashed line from IA header or noted as utility at instrument connections
DCS interlock on P&ID:
- Software interlock shown by diamond/logic symbol or reference to interlock schedule
- None
- Hard-wired always
- Not shown
Show the answer
Answer: A. Software interlock shown by diamond/logic symbol or reference to interlock schedule
SIS trip on P&ID:
- Same as DCS
- Dedicated safety layer
- No separation
- None
Show the answer
Answer: B. Dedicated safety layer Dedicated safety layer - separate from DCS; shown with separate instrument bubble notation or SIS prefix
ESD (Emergency Shutdown) valve symbol:
- No distinction
- None
- Ball valve or gate valve with actuator and position feedback
- Regular valve
Show the answer
Answer: C. Ball valve or gate valve with actuator and position feedback Ball valve or gate valve with actuator and position feedback - normally open or closed
High/low alarm on P&ID:
- None
- HAH/LAH = high-high/low-low alarm; HAL/LAL = high/low alarm
- Not shown on P&ID
- Optional notation
Show the answer
Answer: B. HAH/LAH = high-high/low-low alarm; HAL/LAL = high/low alarm HAH/LAH = high-high/low-low alarm; HAL/LAL = high/low alarm - defined in bubble
PAHH (Pressure Alarm High-High):
- Only for liquids
- Safety alarm triggering emergency action at highest pressure
- None
- Same as PAH
Show the answer
Answer: B. Safety alarm triggering emergency action at highest pressure Safety alarm triggering emergency action (SIS trip) at highest pressure - separate from PAH
Instrument loop diagram:
- None
- General arrangement
- P&ID
- Detailed wiring/tubing of single instrument loop
Show the answer
Answer: D. Detailed wiring/tubing of single instrument loop Detailed wiring/tubing of single instrument loop - terminal strips, cable numbers, power supply
Junction box (J/B) on instrument loop diagram:
- Instrument bubble
- None
- Terminal strip inside box where field wiring joins instrument cable
- Nothing
Show the answer
Answer: C. Terminal strip inside box where field wiring joins instrument cable Terminal strip inside box where field wiring joins instrument cable - shown as rectangle
Marshalling cabinet:
- Field instrument
- DCS cabinet directly
- None
- Intermediate cabinet where field cables are terminated before DCS I/O
Show the answer
Answer: D. Intermediate cabinet where field cables are terminated before DCS I/O Intermediate cabinet where field cables are terminated before DCS I/O - minimises long cable runs to DCS
Multicore cable for instruments:
- One cable per instrument always
- Wireless only
- Multiple pairs in one cable
- None
Show the answer
Answer: C. Multiple pairs in one cable Multiple pairs in one cable - cost-effective for multiple instruments in same area
Intrinsic safety (Ex i) barrier:
- Explosion-proof only
- Limits energy to field instrument in hazardous area
- None
- No protection
Show the answer
Answer: B. Limits energy to field instrument in hazardous area Limits energy to field instrument in hazardous area - Zener barrier or galvanic isolator
Explosion-proof (Ex d) enclosure:
- Instrument in flameproof housing that contains internal explosion without propagating outside
- None
- Intrinsic safety
- Purged enclosure
Show the answer
Answer: A. Instrument in flameproof housing that contains internal explosion without propagating outside
Purged/pressurised enclosure (Ex p):
- None
- Housing filled with inert gas under positive pressure
- Explosion-proof
- Intrinsic safety
Show the answer
Answer: B. Housing filled with inert gas under positive pressure Housing filled with inert gas under positive pressure - excludes flammable atmosphere
Thermowell function:
- Isolation valve
- None
- Direct immersion
- Protects temperature element from process fluid while allowing heat conduction
Show the answer
Answer: D. Protects temperature element from process fluid while allowing heat conduction Protects temperature element from process fluid while allowing heat conduction - removable without shutdown
Orifice plate flow measurement:
- Positive displacement
- None
- Differential pressure across orifice ∝ flow²
- Turbine meter
Show the answer
Answer: C. Differential pressure across orifice ∝ flow² Differential pressure across orifice ∝ flow² - indicated by DP transmitter
Coriolis flow meter principle:
- None
- Differential pressure
- Magnetic
- Measures mass flow directly via Coriolis effect on vibrating tubes
Show the answer
Answer: D. Measures mass flow directly via Coriolis effect on vibrating tubes Measures mass flow directly via Coriolis effect on vibrating tubes - also gives density
Magnetic (electromagnetic) flow meter:
- Gas flow
- Non-conductive liquids
- Measures conductive liquid flow via Faraday's law
- None
Show the answer
Answer: C. Measures conductive liquid flow via Faraday's law Measures conductive liquid flow via Faraday's law - velocity ∝ induced EMF
Ultrasonic flow meter (clamp-on):
- Non-invasive
- Process wetted
- DP type
- None
Show the answer
Answer: A. Non-invasive Non-invasive - measures transit time difference between upstream/downstream ultrasonic pulses
Level measurement - differential pressure method:
- None
- ΔP between vessel bottom tap and top tap gives liquid level
- Only open vessels
- Only float
Show the answer
Answer: B. ΔP between vessel bottom tap and top tap gives liquid level ΔP between vessel bottom tap and top tap gives liquid level - most common for closed vessels
Radar (guided wave) level measurement:
- Microwave pulses reflect off liquid surface
- Float type
- Displacer
- None
Show the answer
Answer: A. Microwave pulses reflect off liquid surface Microwave pulses reflect off liquid surface - used for corrosive, viscous, or high-T liquids
PSSR (Pre-Startup Safety Review):
- [
- "
- i
- F
Show the answer
Answer: A. [
Cold eyes review:
- I
- "
- n
- [
Show the answer
Answer: D. [
As-built vs AFC (Approved for Construction) drawings:
- [
- F
- A
- "
Show the answer
Answer: A. [
PDMS database extract:
- [
- "
- l
- P
Show the answer
Answer: A. [
Process flow assurance:
- n
- [
- E
- "
Show the answer
Answer: B. [
Living document concept in P&ID:
- &
- P
- "
- [
Show the answer
Answer: D. [
Safe access platform on vessel general arrangement:
- l
- P
- [
- "
Show the answer
Answer: C. [
Hazardous area plot plan layer:
- O
- "
- v
- [
Show the answer
Answer: D. [
Valve schedule (valve list):
- [
- a
- D
- "
Show the answer
Answer: A. [
Equipment list purpose:
- T
- [
- "
- a
Show the answer
Answer: B. [
Tie-back drawing:
- h
- [
- S
- "
Show the answer
Answer: B. [
DWG revision cloud purpose:
- H
- "
- i
- [
Show the answer
Answer: D. [
Instrument specification sheet:
- "
- D
- [
- e
Show the answer
Answer: C. [
'IFI' (Issued For Information) drawing:
- [
- E
- "
- a
Show the answer
Answer: A. [
Material class (piping class/spec):
- "
- [
- e
- D
Show the answer
Answer: B. [
Spool isometric drawing includes:
- None
- Only material
- Only dimensions
- Pipe spool number, material, dimensions, weld joints, supports, and test requirements
Show the answer
Answer: D. Pipe spool number, material, dimensions, weld joints, supports, and test requirements
Line specification break on P&ID:
- End of pipe
- None
- Shows change of pipe spec on same line
- Valve symbol
Show the answer
Answer: C. Shows change of pipe spec on same line Shows change of pipe spec (material, rating) on same line - break symbol with new spec label
The practice questions were written for this studio; they are not copied from ASTU papers. ASTU publishes no topic syllabus for these exams, so the topics are an informed guide based on diploma courses, not an official list.