Unit operations and flowsheets, units, gases, Raoult and Dalton, limiting reactant, combustion, humidity, material balances with recycle, bypass and purge, energy balances and spreadsheet solving from the ASTU CHE241304 syllabus.
What is inside
- Unit operations, unit processes and flowsheets
- Gases, Raoult and Dalton, limiting reactant and combustion
- Humidity and the psychrometric chart
- Material and energy balances with recycle, bypass and purge
Syllabus: ASTU CHE241304 Introduction to Chemical Engineering, semester 3, NEP 2020 (2024-25 onwards). Official syllabus PDF.
Introduction: unit operations, unit processes and flowsheets
Topics: Introduction to various unit operations and processes and their applications, preparation of flowsheets.
Unit operations, unit processes and how a plant is drawn
Chemical engineering turns raw materials into useful products on a large scale, safely and economically. Arthur D. Little’s idea (1915) was that every plant, however different its product, is built from a small set of common steps. Physical steps that change the state, phase, size or composition of material without chemical change are unit operations: fluid flow, heat transfer (heat exchangers, evaporators), mass transfer (distillation, absorption, extraction, drying, crystallisation, adsorption) and mechanical operations (size reduction, screening, filtration, settling, mixing). Steps that involve chemical change are unit processes: combustion, oxidation, reduction, hydrogenation, nitration, sulphonation, halogenation, esterification, polymerisation, fermentation, cracking and so on.
A typical process therefore has the pattern: raw-material preparation (unit operations) → reaction (unit process) → separation and purification (unit operations) → product, with recycle of unreacted material and treatment of wastes. Sulphuric acid, for example, burns sulphur (combustion), oxidises SO₂ over V₂O₅ (catalytic oxidation) and absorbs SO₃ in strong acid (absorption, a unit operation), with heat exchangers recovering heat throughout.
Plants are described by drawings of increasing detail. A block flow diagram (BFD) shows major sections as rectangles joined by arrows with main flows. A process flow diagram (PFD) shows each major equipment item with its standard symbol, the main process streams with numbers, a stream table (flow, composition, temperature, pressure) and the key control loops. A piping and instrumentation diagram (P&ID) adds every line with size and specification, every valve, instrument and control loop, and is the basis for construction and operation. Equipment symbols (pumps, exchangers, columns, vessels, reactors) follow standards such as ISO 10628 or IS 3232.
- Unit operation: physical change (distillation, filtration, drying…).
- Unit process: chemical change (oxidation, nitration, polymerisation…).
- BFD → PFD → P&ID: increasing detail.
- A PFD has equipment symbols, numbered streams and a stream table.
Example: Classify each step of soap making as a unit operation or a unit process: melting fat, saponification with NaOH, salting out, filtering, drying, milling.
- Melting fat: heat transfer, a unit operation.
- Saponification: chemical reaction (ester hydrolysis), a unit process.
- Salting out: separation by solubility change, a unit operation.
- Filtering, drying and milling: mechanical and mass-transfer steps, unit operations.
Answer: Only saponification is a unit process; the rest are unit operations.
Example: List what a PFD must show that a block diagram does not.
- Each major item of equipment with its standard symbol and tag number (P-101, E-101, T-101).
- Every main process stream, numbered, with direction.
- A stream table: flow, composition, temperature, pressure and phase of each stream.
- Utility streams (steam, cooling water) and the main control loops.
Answer: Equipment symbols, numbered streams, a stream table, utilities and key controls.
Every chemical plant is a combination of unit operations (physical changes: fluid flow, heat transfer, mass transfer, mechanical operations) and unit processes (chemical changes: oxidation, reduction, hydrogenation, nitration, sulphonation, polymerisation, fermentation, cracking). Plants are documented by block flow diagrams, process flow diagrams (equipment symbols, numbered streams, stream table) and piping and instrumentation diagrams (every line, valve and instrument).
- Unit operations concept: A. D. Little, 1915.
- Typical sequence: prepare → react → separate → purify, with recycle.
- Equipment tags: P pump, E exchanger, T tower, V vessel, R reactor.
- P&ID is the basis for construction, HAZOP and operation.
Key formulas
- Process = unit operations + unit processes
- BFD ⊂ PFD ⊂ P&ID (detail)
Practice questions
Distillation is a
- unit process
- unit operation
- reaction
- utility
Show the answer
Answer: B. unit operation Physical separation.
Nitration of benzene is a
- unit operation
- unit process
- mechanical operation
- heat transfer
Show the answer
Answer: B. unit process Chemical change.
A diagram showing every valve, instrument and line size is the
- BFD
- PFD
- P&ID
- Gantt chart
Show the answer
Answer: C. P&ID Piping and instrumentation diagram.
The stream table is part of the
- PFD
- site plan
- P&ID only
- layout drawing
Show the answer
Answer: A. PFD Flows, compositions, conditions.
The unit operations concept was proposed by
- Le Chatelier
- A. D. Little
- Fourier
- Reynolds
Show the answer
Answer: B. A. D. Little 1915.
Theory questions
Distinguish between unit operations and unit processes with three examples of each. (4 marks)
Show the model answer
Unit operations involve only physical change (state, phase, size, composition by separation): distillation, filtration, drying, heat exchange, evaporation, crushing. Unit processes involve chemical change, governed by reaction kinetics and equilibrium: oxidation (SO₂ → SO₃), nitration (benzene → nitrobenzene), polymerisation (ethylene → polyethylene), hydrogenation of oils. A process combines both, e.g. reaction followed by separation.
Explain the purpose and contents of a block flow diagram, a process flow diagram and a P&ID. (5 marks)
Show the model answer
BFD: overview of the process in blocks (sections) with main flows; used in early studies. PFD: all major equipment with standard symbols and tags, main process and utility streams numbered, stream table of flows, compositions, T and P, heat duties and key control loops; used for design and balances. P&ID: every pipe with size, material and insulation, every valve, instrument, control and safety device, vents and drains; used for detailed design, construction, HAZOP and operation.
Basic calculations
Topics: Units and dimensions, ideal gases and real gases, applications of Raoult’s law and Dalton’s law, chemical reactions, excess and limiting reactant, conversion, yield and selectivity, combustion calculations.
Units, the mole and composition
Every stoichiometry problem starts by putting quantities on a common basis. A mole is an amount: 1 kmol of a substance has a mass in kilograms equal to its molar mass. Compositions are given as mass fractions, mole fractions or volume fractions (for ideal gases, volume fraction = mole fraction).
Solution strengths: molarity (mol per litre of solution), molality (mol per kg of solvent), normality (equivalents per litre), ppm (mg per kg, roughly mg per litre for dilute water solutions). Choose a basis such as 100 kg or 100 kmol and convert everything to it.
- Choose a basis first (100 kg or 100 kmol)
- Mole fraction xᵢ = nᵢ / Σn
- Molarity: mol/L of solution; molality: mol/kg of solvent
Example: A mixture is 40 % benzene (M = 78) and 60 % toluene (M = 92) by mass. Find the mole fraction of benzene.
- Basis 100 kg: benzene 40/78 = 0.513 kmol, toluene 60/92 = 0.652 kmol.
- x_B = 0.513/(0.513 + 0.652) = 0.440.
Answer: 0.440
Example: 4 g of NaOH is dissolved to make 250 mL of solution. Find the molarity.
- n = 4/40 = 0.1 mol.
- M = 0.1/0.250 = 0.4 mol/L.
Answer: 0.4 M
Gases, vapour pressure and humidity
For ideal gases PV = nRT with R = 8.314 kJ/(kmol·K); 1 kmol occupies 22.414 m³ at NTP (0 °C, 1 atm). Gas density = PM/RT. Dalton’s law: partial pressure pᵢ = yᵢP; Amagat’s law: pure-component volumes add up.
Vapour pressure rises steeply with temperature (Antoine or Clausius–Clapeyron). Humidity is the mass of water vapour per mass of dry air; percentage saturation compares it with the saturated value at the same temperature.
- PV = nRT; ρ = PM/RT
- pᵢ = yᵢP (Dalton)
- 1 kmol = 22.414 m³ at NTP
Example: Find the density of CO₂ at 1 atm and 27 °C.
- ρ = PM/RT = 101 325 × 44 / (8314 × 300).
- = 1.79 kg/m³.
Answer: ≈ 1.79 kg/m³
Example: Air is 21 % O₂ by volume. Find the partial pressure of O₂ at 1 atm.
- Volume fraction = mole fraction = 0.21.
- p = 0.21 × 1 = 0.21 atm.
Answer: 0.21 atm
Reactions, limiting reactant, conversion, yield, selectivity and combustion
A balanced chemical equation gives the stoichiometric ratios in moles. The limiting reactant is the one present in less than the stoichiometric proportion relative to the others: divide the moles fed of each reactant by its coefficient; the smallest ratio is limiting. The percent excess of another reactant is (moles fed − moles needed to react all the limiting reactant)/(moles needed) × 100.
Fractional conversion of a reactant is the fraction of it fed that reacts. When side reactions occur, yield and selectivity describe how well the wanted product is made. Yield (based on feed) = moles of desired product formed/moles that would form if all the limiting reactant reacted to it; yield (based on consumption) = desired product formed/limiting reactant consumed (both in stoichiometric terms). Selectivity = moles of desired product/moles of undesired product. The extent of reaction ξ links them: n_i = n_i0 + ν_i ξ, with ν negative for reactants.
Combustion calculations use the same ideas. Theoretical oxygen is that needed for complete combustion of the fuel (C → CO₂, H → H₂O, S → SO₂), whether or not combustion is actually complete. Theoretical air = theoretical O₂/0.21; percent excess air = (air fed − theoretical)/theoretical × 100. Every mole of O₂ in air brings 79/21 = 3.76 mol N₂. Flue (stack) gas composition on a wet basis includes water; on a dry basis (as given by the Orsat analyser) it does not.
Raoult’s law p_i = x_i p_i° and Dalton’s law P = Σp_i, y_i = p_i/P describe ideal vapour–liquid mixtures. They give the bubble point (liquid begins to boil, Σx_i p_i° = P) and the dew point (vapour begins to condense, Σy_i/p_i° = 1/P), with vapour pressures from the Antoine equation log p° = A − B/(T + C).
- n_i = n_i0 + ν_i ξ.
- % excess = (fed − needed)/needed × 100.
- Theoretical air = theoretical O₂/0.21; N₂/O₂ = 3.76.
- Bubble point: Σx_i p_i° = P; dew point: Σ y_i/p_i° = 1/P.
Example: Convert a heat capacity of 1 Btu/(lb·°F) into kJ/(kg·K).
- 1 Btu = 1.05506 kJ; 1 lb = 0.45359 kg; a temperature difference of 1 °F = 5/9 K.
- 1 Btu/(lb·°F) = 1.05506/(0.45359 × 5/9) kJ/(kg·K).
- = 1.05506/0.25200 = 4.1868.
Answer: 4.1868 kJ/(kg·K), the heat capacity of water.
Example: Propane is burnt with 20 % excess air. Find the Orsat (dry) analysis of the flue gas, assuming complete combustion.
- C₃H₈ + 5O₂ → 3CO₂ + 4H₂O; basis 1 mol propane.
- Theoretical O₂ = 5; supplied = 6; N₂ = 6 × 3.76 = 22.57 mol.
- Flue gas: CO₂ 3, H₂O 4, O₂ 6 − 5 = 1, N₂ 22.57 mol.
- Dry total = 3 + 1 + 22.57 = 26.57 mol: CO₂ 11.29 %, O₂ 3.76 %, N₂ 84.95 %.
Answer: CO₂ 11.3 %, O₂ 3.8 %, N₂ 84.9 % (dry basis).
Example: In ethylene oxide production, 100 mol C₂H₄ is fed, 50 mol reacts, 40 mol giving C₂H₄O and 10 mol burning to CO₂ (C₂H₄ + 3O₂ → 2CO₂ + 2H₂O). Find conversion, yields and selectivity.
- Conversion of ethylene = 50/100 = 50 %.
- Yield based on feed = 40/100 = 40 %.
- Yield based on consumption = 40/50 = 80 %.
- Selectivity = mol EO formed/mol C₂H₄ to side reaction = 40/10 = 4.
Answer: 50 % conversion, 40 % (feed) and 80 % (consumption) yield, selectivity 4.
Example: A liquid of 40 mol % benzene and 60 % toluene is held at 100 °C, where p°(benzene) = 1350 mmHg and p°(toluene) = 556 mmHg. Find the total pressure and the vapour composition at equilibrium.
- p_B = 0.4 × 1350 = 540 mmHg; p_T = 0.6 × 556 = 334 mmHg.
- P = 540 + 334 = 874 mmHg.
- y_B = 540/874 = 0.618; y_T = 0.382.
Answer: P = 874 mmHg; the vapour is 61.8 % benzene.
Use consistent units (SI; gc = 1 kg·m/N·s²); keep dimensions in every step. Ideal gas pV = nRT; real gases via compressibility Z or van der Waals (p + an²/V²)(V − nb) = nRT. Raoult (p_i = x_i p_i°) and Dalton (y_i = p_i/P) give bubble and dew points. Limiting reactant = smallest feed/coefficient; % excess; conversion; yield (feed or consumption basis); selectivity; extent of reaction. Combustion: theoretical O₂ for complete combustion, excess air, wet and dry (Orsat) flue-gas analysis.
- Molar volume at STP (0 °C, 1 atm) = 22.414 L/mol.
- R = 8.314 J/mol·K = 0.08206 L·atm/mol·K.
- Excess air is based on complete combustion even if CO forms.
- Partial pressure fraction = mole fraction = volume fraction (ideal gas).
Key formulas
- pV = nRT ; pV = ZnRT
- (p + an²/V²)(V − nb) = nRT
- p_i = x_i p_i° ; y_i = p_i/P
- log p° = A − B/(T + C)
- n_i = n_i0 + ν_i ξ
Practice questions
A gas with Z < 1 is
- easier to compress than an ideal gas
- harder to compress
- ideal
- a liquid
Show the answer
Answer: A. easier to compress than an ideal gas Attraction dominates.
100 mol N₂ and 240 mol H₂ are fed for N₂ + 3H₂ → 2NH₃. The limiting reactant is
- N₂
- H₂
- NH₃
- neither
Show the answer
Answer: B. H₂ 240/3 = 80 < 100.
Theoretical air for burning 1 mol CH₄ is about
- 2 mol
- 4.76 mol
- 9.52 mol
- 21 mol
Show the answer
Answer: C. 9.52 mol 2/0.21.
The Orsat analysis of flue gas is on a
- wet basis
- dry basis
- mass basis
- volume of fuel basis
Show the answer
Answer: B. dry basis Water removed.
By Raoult’s law, the partial pressure of a component is
- y_i P
- x_i p_i°
- p_i°/x_i
- P/x_i
Show the answer
Answer: B. x_i p_i° Ideal solution.
Selectivity compares
- product to feed
- desired to undesired product
- reacted to fed
- outlet to inlet temperature
Show the answer
Answer: B. desired to undesired product Definition.
Theory questions
Define limiting reactant, excess reactant, conversion, yield and selectivity, with a numerical example. (6 marks)
Show the model answer
Limiting reactant: present in less than the stoichiometric amount (smallest n_fed/ν). Excess reactant: the others; % excess = (fed − required)/required × 100. Conversion: fraction of a reactant fed that reacts. Yield: desired product formed relative to the maximum possible (feed basis) or relative to reactant consumed (consumption basis). Selectivity: desired/undesired product formed. Example: 100 mol N₂ + 240 mol H₂ (N₂ + 3H₂ → 2NH₃): H₂ limiting (80 < 100), N₂ in 25 % excess (needed 80). If 60 % of H₂ reacts, ξ = 48, NH₃ = 96 mol, yield on feed = 96/160 = 60 %.
Explain the bubble point and dew point of an ideal binary mixture and how they are calculated. (5 marks)
Show the model answer
Bubble point: temperature (at given P) at which a liquid of composition x first forms a vapour bubble; condition Σx_i p_i°(T) = P, found by trial or Goal Seek with Antoine vapour pressures; the first bubble has y_i = x_i p_i°/P. Dew point: temperature at which a vapour of composition y first condenses; condition Σy_i P/p_i°(T) = 1; the first drop has x_i = y_i P/p_i°. The bubble point is always below the dew point for the same composition; between them the mixture is two-phase.
Explain theoretical oxygen, excess air and the Orsat analysis in combustion calculations. (4 marks)
Show the model answer
Theoretical O₂ is the oxygen needed to burn all C to CO₂, H to H₂O and S to SO₂ (minus O already in the fuel). Theoretical air = theoretical O₂/0.21. Excess air (%) = (air supplied − theoretical air)/theoretical air × 100, always based on complete combustion even if some CO forms. The flue gas contains CO₂, CO, O₂, N₂, H₂O and SO₂. The Orsat apparatus absorbs CO₂ (KOH), O₂ (alkaline pyrogallol) and CO (cuprous chloride) from a sample at room temperature, after the water has condensed, so it reports a dry-basis analysis.
Humidity and the psychrometric chart
Topics: Saturation, humidity, humid heat, adiabatic saturation temperature, humid volume and enthalpy, applications of the psychrometric chart.
Humidity terms and the psychrometric chart
Air–water vapour mixtures are described per kilogram of dry air, because the amount of dry air stays constant through dryers, humidifiers and cooling towers while the water content changes. Absolute (mass) humidity H = mass of water/mass of dry air = 0.622 p_v/(P − p_v), where 0.622 = 18.02/28.97. The air is saturated when p_v equals the vapour pressure p_s at its temperature; H_s = 0.622 p_s/(P − p_s). Relative humidity = p_v/p_s × 100; percentage saturation = H/H_s × 100 (slightly smaller).
The dew point is the temperature at which air, cooled at constant humidity, becomes saturated (p_s(T_dp) = p_v); cooling below it condenses water. Humid heat c_s = 1.005 + 1.88H kJ/(kg dry air·K) is the heat to warm 1 kg dry air plus its vapour by 1 K. Humid volume v_H = (1/28.97 + H/18.02)RT/P is the volume of 1 kg dry air with its vapour. Humid enthalpy (0 °C, liquid water reference) h = 1.005T + H(2501 + 1.88T) kJ/kg dry air.
If unsaturated air contacts water in an insulated chamber, water evaporates, taking its latent heat from the air, which cools and humidifies until saturated at the adiabatic saturation temperature T_as: H_s(T_as) − H = c_s(T − T_as)/λ_as. For air–water the wet-bulb temperature equals T_as (Lewis relation h/(k_y c_s) ≈ 1), which is why a wet-bulb thermometer gives the humidity.
The psychrometric chart plots H against dry-bulb temperature at 1 atm, with curves of constant relative humidity (100 % is the saturation curve), adiabatic saturation (wet-bulb) lines sloping down to the left, and scales of humid volume and enthalpy. Any two properties fix the state; the others are read off. Heating moves a point horizontally right; cooling moves it left to the saturation curve then down along it (dehumidification); adiabatic humidification moves it along a wet-bulb line; mixing two airstreams gives a point on the straight line joining them.
- H = 0.622 p_v/(P − p_v) kg/kg dry air.
- RH = p_v/p_s; % saturation = H/H_s.
- c_s = 1.005 + 1.88H; v_H = (1/29 + H/18)RT/P.
- h = 1.005T + H(2501 + 1.88T).
- Wet bulb ≈ adiabatic saturation temperature (air–water).
Example: Air at 30 °C and 60 % RH, 1 atm (p_s at 30 °C = 4.246 kPa). Find H, dew point, humid heat, humid volume and enthalpy.
- p_v = 0.6 × 4.246 = 2.548 kPa.
- H = 0.622 × 2.548/(101.325 − 2.548) = 0.01604 kg/kg dry air.
- Dew point: p_s = 2.548 kPa at about 21.4 °C (steam tables).
- c_s = 1.005 + 1.88 × 0.01604 = 1.035 kJ/kg·K.
- v_H = (1/28.97 + 0.01604/18.02) × 8.314 × 303.15/101.325 = 0.0354 × 24.87 = 0.881 m³/kg dry air.
- h = 1.005 × 30 + 0.01604 × (2501 + 56.4) = 30.15 + 41.02 = 71.2 kJ/kg dry air.
Answer: H = 0.0160, dew point ≈ 21.4 °C, c_s = 1.035 kJ/kg·K, v_H = 0.881 m³/kg, h = 71.2 kJ/kg.
Example: That air is cooled to 15 °C (p_s = 1.705 kPa). How much water condenses per kg of dry air?
- 15 °C is below the dew point (21.4 °C), so the air leaves saturated.
- H_s(15 °C) = 0.622 × 1.705/(101.325 − 1.705) = 0.01065 kg/kg.
- Condensed = 0.01604 − 0.01065 = 0.00539 kg/kg dry air.
Answer: About 5.4 g of water per kg of dry air.
Humidity is counted per kg of dry air: H = 0.622 p_v/(P − p_v). Relative humidity p_v/p_s and percentage saturation H/H_s; dew point where p_s = p_v. Humid heat c_s = 1.005 + 1.88H, humid volume (1/29 + H/18)RT/P, enthalpy 1.005T + H(2501 + 1.88T). Adiabatic saturation temperature from H_s − H = c_s(T − T_as)/λ; for air–water equal to the wet-bulb temperature. The psychrometric chart shows all of these and traces heating, cooling, humidification and mixing.
- Heating at constant H lowers RH.
- Cooling below the dew point condenses water.
- Adiabatic humidification follows a wet-bulb line (constant enthalpy, nearly).
- Mixing two airstreams: the mix lies on the straight line joining them (by mass of dry air).
Key formulas
- H = 0.622 p_v/(P − p_v)
- c_s = 1.005 + 1.88H kJ/kg·K
- v_H = (1/28.97 + H/18.02) RT/P
- h = 1.005T + H(2501 + 1.88T)
- H_s − H = c_s(T − T_as)/λ_as
Practice questions
Absolute humidity is expressed as
- kg water/kg humid air
- kg water/kg dry air
- % of saturation
- kPa
Show the answer
Answer: B. kg water/kg dry air Dry-air basis.
At the dew point the relative humidity is
- 0 %
- 50 %
- 100 %
- undefined
Show the answer
Answer: C. 100 % Saturated.
For the air–water system the wet-bulb temperature is nearly equal to the
- dew point
- dry-bulb temperature
- adiabatic saturation temperature
- boiling point
Show the answer
Answer: C. adiabatic saturation temperature Lewis relation.
Heating air without adding water
- raises its humidity
- lowers its relative humidity
- raises its dew point
- saturates it
Show the answer
Answer: B. lowers its relative humidity p_s rises, p_v constant.
Humid heat of air with H = 0.01 kg/kg is about
- 1.005
- 1.024
- 1.88
- 4.18
Show the answer
Answer: B. 1.024 1.005 + 0.0188 kJ/kg·K.
Theory questions
Define absolute humidity, relative humidity, percentage saturation, dew point, humid heat and humid volume. (6 marks)
Show the model answer
Absolute humidity H: kg water vapour per kg dry air = 0.622 p_v/(P − p_v). Relative humidity: p_v/p_s × 100 at the same temperature. Percentage saturation: H/H_s × 100. Dew point: temperature at which the air becomes saturated on cooling at constant pressure and humidity. Humid heat: heat to raise 1 kg dry air and its vapour by 1 K = 1.005 + 1.88H kJ/kg·K. Humid volume: volume of 1 kg dry air plus its vapour = (1/28.97 + H/18.02)RT/P.
Derive the equation for the adiabatic saturation temperature and explain why it equals the wet-bulb temperature for air–water. (5 marks)
Show the model answer
Air (T, H) enters an insulated chamber, leaves saturated at T_as with H_as; make-up water enters at T_as. Enthalpy balance per kg dry air with T_as as reference: c_s(T − T_as) = (H_as − H)λ_as, so (H_as − H)/(T − T_as) = c_s/λ_as. A wet bulb is in steady state when heat convected to it equals latent heat of the water evaporating: h(T − T_w) = k_y λ_w(H_w − H), so (H_w − H)/(T − T_w) = h/(k_y λ_w). The two coincide when h/(k_y c_s) = 1, the Lewis relation, which holds closely for air–water (≈ 0.96).
Material balances for non-reactive processes
Topics: Application of material balance principles, degree of freedom, choosing a basis, material balances without chemical reaction, recycle, bypass and purge calculations.
The material balance method and degrees of freedom
The law of conservation of mass gives the general balance: input + generation − output − consumption = accumulation. At steady state with no reaction this becomes input = output, for the total mass and for each component. For a process with N components, N independent balances can be written for each unit (the total balance is not independent of the component balances).
A systematic method avoids most mistakes: (1) draw and label a flowchart, writing every known flow and composition on it; (2) choose a basis of calculation (a given flow, or 100 kg or 100 mol of a stream if nothing is given); (3) count degrees of freedom; (4) write balances, starting with those having one unknown (tie components, which pass through unchanged, are useful); (5) solve and check with a balance not used; (6) scale to the actual flow if needed.
Degrees of freedom (DOF) = number of unknowns − number of independent equations (material balances, specified relations such as recoveries or ratios, and the requirement that mole fractions sum to one). If DOF = 0 the problem is solvable; DOF > 0 means more information is needed; DOF < 0 means the problem is overspecified and the data may be inconsistent. For multi-unit processes, count DOF for each unit, mixing and splitting point and for the whole process, and start with a sub-system that has zero DOF.
A splitter divides a stream into streams of the same composition, so it gives only one independent balance (total). A mixer combines streams. Recycle returns part of an outlet stream to an earlier point (to recover unconverted feed, solvent or catalyst, or to control conditions). Bypass sends part of the feed around a unit. Purge is a small stream bled off a recycle loop to stop impurities building up.
- Input + generation − output − consumption = accumulation.
- DOF = unknowns − independent equations.
- Splitter: same composition in all outlets (1 balance).
- Recycle ratio = recycle flow/fresh feed.
Example: 1000 kg/h of 40 wt % benzene/60 % toluene is distilled into a distillate with 95 % benzene and bottoms with 4 % benzene. Find the product rates and benzene recovery.
- DOF: unknowns D, W; equations: total and benzene balances ⇒ DOF = 0.
- Total: 1000 = D + W. Benzene: 400 = 0.95D + 0.04W.
- Substitute W = 1000 − D: 400 = 0.95D + 40 − 0.04D ⇒ 0.91D = 360 ⇒ D = 395.6 kg/h, W = 604.4 kg/h.
- Benzene recovery = 0.95 × 395.6/400 = 94.0 %.
Answer: D = 395.6 kg/h, W = 604.4 kg/h, 94 % of the benzene recovered.
Example: 10 000 kg/h of 20 wt % KNO₃ solution goes to an evaporator that makes 50 % solution; this feeds a crystalliser giving crystals (96 % KNO₃, 4 % water) and mother liquor (37.5 % KNO₃) that is recycled to the evaporator. Find the crystal rate, water evaporated and recycle rate.
- Overall KNO₃: 0.20 × 10 000 = 0.96P ⇒ P = 2083 kg/h of crystals.
- Overall water evaporated: W = 10 000 − 2083 = 7917 kg/h.
- Crystalliser: total m = P + R; KNO₃ 0.5m = 0.96P + 0.375R.
- 0.5(P + R) = 0.96P + 0.375R ⇒ 0.125R = 0.46P ⇒ R = 3.68 × 2083 = 7667 kg/h.
Answer: Crystals 2083 kg/h, water evaporated 7917 kg/h, recycle 7667 kg/h (recycle ratio 0.77).
General balance: input + generation − output − consumption = accumulation; at steady state without reaction, input = output for total and each component. Method: flowchart, basis, degree-of-freedom analysis, balances (tie component first), check, scale. DOF = unknowns − independent equations (must be zero). Multi-unit systems: overall, unit, mixer and splitter balances. Recycle returns material, bypass skips a unit, purge bleeds a loop to limit impurity build-up.
- Choose a basis: given flow, or 100 kg/100 mol of a stream.
- Only N independent balances for N components.
- Overall balances ignore internal recycle streams.
- Splitter outlets have the feed composition.
Key formulas
- Input + Gen − Out − Cons = Acc
- DOF = n_unknowns − n_equations
- F x_F = P x_P (tie component)
- Recycle ratio = R/F
Practice questions
For a non-reactive steady process with 3 components, the number of independent material balances per unit is
- 1
- 2
- 3
- 4
Show the answer
Answer: C. 3 One per component.
A splitter provides how many independent balances?
- 0
- 1
- one per component
- two
Show the answer
Answer: B. 1 Outlets have equal composition.
Degrees of freedom greater than zero means the problem is
- solvable
- underspecified
- overspecified
- inconsistent
Show the answer
Answer: B. underspecified More data needed.
A purge stream is used to
- increase conversion
- prevent accumulation of inerts in a recycle loop
- bypass a reactor
- cool a reactor
Show the answer
Answer: B. prevent accumulation of inerts in a recycle loop Bleed.
An evaporator concentrates 1000 kg/h of 10 % salt to 40 %. Water evaporated is
- 250 kg/h
- 750 kg/h
- 600 kg/h
- 400 kg/h
Show the answer
Answer: B. 750 kg/h P = 100/0.4 = 250 kg/h.
Theory questions
Explain degree-of-freedom analysis for material balance problems, with an example. (5 marks)
Show the model answer
DOF = number of unknown stream variables − number of independent equations (component balances, specified relations, Σx = 1). For a separator fed 100 mol/h of A–B (x_A = 0.5) giving a top stream x_A = 0.9 and a bottom stream x_A = 0.1: unknowns 2 (top and bottom flows), equations 2 (A and B balances) ⇒ DOF = 0, solvable: top 50, bottom 50 mol/h. If the bottom composition were unknown, DOF = 1 and one more specification (e.g. A recovery) would be needed.
Distinguish between recycle, bypass and purge, giving reasons for each. (4 marks)
Show the model answer
Recycle: part of an outlet stream returned to an earlier point; recovers unconverted reactant, solvent or catalyst, raises overall conversion, dilutes reactant or controls temperature. Bypass: part of the feed goes around a unit and rejoins downstream; used to control product composition or temperature without over-processing. Purge: a small stream withdrawn from a recycle loop so that inerts or impurities that enter with the feed but are not removed elsewhere do not accumulate.
Material balances for reactive processes
Topics: Material balances with chemical reaction, recycle, bypass and purge calculations.
Material balances, recycle and reaction
The balance equation is Input + Generation − Output − Consumption = Accumulation; at steady state without reaction, input = output for every component. Use a tie component (one that passes unchanged, like a dry solid or inert gas) to link streams quickly.
With reaction, find the limiting reactant (the one that runs out first by stoichiometry); % excess = (supplied − required)/required × 100. Single-pass conversion is per trip through the reactor; recycling unreacted feed raises the overall conversion.
- In = Out at steady state (no reaction)
- Tie component links streams
- % excess = (supplied − needed)/needed × 100
Example: An evaporator concentrates 1000 kg/h of 10 % salt solution to 40 %. How much water is evaporated?
- Salt balance: 100 kg/h of salt leaves in the product, so product = 100/0.40 = 250 kg/h.
- Water evaporated = 1000 − 250 = 750 kg/h.
Answer: 750 kg/h
Example: N₂ + 3H₂ → 2NH₃ is fed with 100 mol N₂ and 240 mol H₂. Find the limiting reactant and % excess of the other.
- 100 mol N₂ needs 300 mol H₂, but only 240 are fed: H₂ is limiting.
- 240 mol H₂ needs 80 mol N₂; excess = (100 − 80)/80 × 100 = 25 %.
Answer: H₂ limiting; N₂ 25 % excess
Example: A reactor converts 25 % of A per pass; unreacted A is fully recycled. For 100 mol/h fresh A, find the reactor feed and recycle.
- Overall all A is converted, so reacted = 100 mol/h = 0.25 × reactor feed.
- Reactor feed = 400 mol/h; recycle = 300 mol/h.
Answer: feed 400, recycle 300 mol/h
Molecular, atomic and extent-of-reaction balances; recycle and purge with reaction
With reaction, the generation and consumption terms are no longer zero. Three equivalent methods exist. Molecular-species balances: for each species, input + generation − output − consumption = 0, with generation and consumption from stoichiometry. Extent of reaction: n_i,out = n_i,in + Σ ν_ij ξ_j for each reaction j; there are as many extents as independent reactions. Atomic balances: atoms are neither created nor destroyed, so input = output for each element, with no generation term; this is convenient for combustion and when the reactions are not known in detail.
For processes with recycle, distinguish single-pass conversion (reactant converted in one pass/reactant entering the reactor) from overall conversion (reactant converted/fresh reactant entering the process). With complete recycle of unreacted reactant and a separator that removes all product, the overall conversion approaches 100 % even if the single-pass conversion is low; the price is a large recycle flow and bigger equipment.
If the fresh feed contains an inert (argon in ammonia synthesis, methane in hydrogen streams) that is not separated out, a purge is needed. The overall inert balance fixes it at once: inert in fresh feed = inert leaving in the purge. A lower allowed inert concentration means a bigger purge and more reactant lost with it. Bypass with reaction works as before: overall balances first, then balances round the mixing point.
- Single-pass conversion = (reactor in − reactor out)/reactor in.
- Overall conversion = (fresh in − process out)/fresh in.
- Atomic balances have no generation term.
- Inert in = inert purged (fixes the purge).
Example: A → B is carried out with 20 % single-pass conversion. All unreacted A is separated and recycled; all B leaves as product. For 100 mol/h fresh A, find the reactor feed and recycle flow.
- All A eventually reacts, so overall conversion = 100 % and product B = 100 mol/h.
- Reactor: 20 % of the reactor feed F reacts: 0.2F = 100 ⇒ F = 500 mol/h.
- Recycle = F − fresh = 500 − 100 = 400 mol/h (recycle ratio 4).
Answer: Reactor feed 500 mol/h, recycle 400 mol/h.
Example: 100 mol of CH₄ is burnt with 20 % excess air; 90 % of the carbon forms CO₂ and 10 % CO. Find the dry flue-gas analysis.
- Theoretical O₂ = 200 mol (complete combustion); supplied = 240; N₂ = 240 × 3.76 = 902.9 mol.
- Carbon: CO₂ 90, CO 10 mol. Hydrogen: H₂O 200 mol.
- Oxygen used = 90 + 10/2 + 200/2 = 195 mol ⇒ O₂ left = 45 mol.
- Dry flue gas = 90 + 10 + 45 + 902.9 = 1047.9 mol: CO₂ 8.59 %, CO 0.95 %, O₂ 4.29 %, N₂ 86.16 %.
Answer: CO₂ 8.6 %, CO 1.0 %, O₂ 4.3 %, N₂ 86.2 % (dry).
Example: Fresh feed of 100 mol/h contains 0.5 % inert; single-pass conversion is 25 %; the recycle may contain at most 5 % inert. Find the purge, recycle and overall conversion (product fully separated).
- Inert balance: 0.5 = 0.05P ⇒ P = 10 mol/h; reactant lost in purge = 9.5 mol/h.
- Reactant entering the reactor = 99.5 + 0.95R; unreacted = 0.75 of that = 0.95(R + P).
- 0.75(99.5 + 0.95R) = 0.95R + 9.5 ⇒ 74.63 − 9.5 = 0.95R − 0.7125R ⇒ R = 65.13/0.2375 = 274.2 mol/h.
- Reacted = 99.5 − 9.5 = 90 mol/h ⇒ overall conversion = 90/99.5 = 90.5 %.
Answer: Purge 10 mol/h, recycle 274 mol/h, overall conversion 90.5 %.
With reaction use molecular balances (with generation/consumption), extent of reaction (n_out = n_in + Σν_ij ξ_j) or atomic balances (no generation). Single-pass conversion refers to the reactor, overall conversion to the whole process; recycle of unreacted feed raises overall conversion. An inert in the feed requires a purge, sized by the inert balance. Combustion with incomplete burning is handled by atomic (C, H, O, N) balances.
- Number of extents = number of independent reactions.
- Atom balances suit combustion and complex reactions.
- Low single-pass conversion → large recycle.
- Purge loses some reactant: a cost trade-off.
Key formulas
- n_i,out = n_i,in + Σ ν_ij ξ_j
- X_sp = (R_in − R_out)/R_in (reactor)
- X_ov = (F_fresh − P_out)/F_fresh
- Inert: F₀ x_I = P y_I
Practice questions
With complete recycle of unreacted feed and perfect separation, the overall conversion is
- equal to single-pass conversion
- 100 %
- zero
- 50 %
Show the answer
Answer: B. 100 % Nothing unreacted leaves.
Atomic balances do not need
- a basis
- generation and consumption terms
- stream flows
- compositions
Show the answer
Answer: B. generation and consumption terms Atoms are conserved.
Purge flow is fixed mainly by the balance on
- product
- inert
- water
- energy
Show the answer
Answer: B. inert Inert leaves only in the purge.
If single-pass conversion is 20 % and fresh feed 100 mol/h (all converted overall), the recycle is
- 80 mol/h
- 400 mol/h
- 500 mol/h
- 20 mol/h
Show the answer
Answer: B. 400 mol/h Reactor feed 500.
Extent of reaction has units of
- mol (or mol/h)
- dimensionless
- kJ
- kg/mol
Show the answer
Answer: A. mol (or mol/h) Moles reacted per unit coefficient.
Theory questions
Explain the three methods of solving material balances with reaction and when each is preferred. (5 marks)
Show the model answer
(1) Molecular species balances: input + generation − output − consumption = 0 for each species; natural when the reactions and their stoichiometry are known. (2) Extent of reaction: n_i,out = n_i,in + Σν_ij ξ_j; reduces unknowns to one extent per independent reaction, convenient for multiple reactions and equilibrium. (3) Atomic (element) balances: in = out for each element, no generation term; preferred for combustion, for processes with many species but few elements, or when reactions are not specified. All give the same answer when correctly applied.
Distinguish between single-pass and overall conversion, and explain the need for a purge stream with a numerical illustration. (5 marks)
Show the model answer
Single-pass conversion = reactant converted in the reactor/reactant entering the reactor. Overall conversion = reactant converted in the process/fresh reactant fed. With recycle of unconverted reactant, overall ≫ single pass (e.g. 25 % per pass, about 90 % overall). If an inert enters with the fresh feed and is not removed by the separator, it accumulates in the recycle loop without limit; a purge withdraws it. Inert balance: inert in fresh feed = purge flow × inert fraction; for 0.5 mol/h inert and 5 % allowed, purge = 10 mol/h, which also removes 9.5 mol/h of reactant.
Energy balance
Topics: Concepts of steady-state and unsteady-state processes, standard heat (enthalpy) of formation, heat of reaction, heat of combustion, balances on non-reactive processes, balances on reactive processes.
Energy balances: closed, open, steady and unsteady
Energy appears as internal energy U, kinetic energy mv²/2 and potential energy mgz, and crosses a system boundary as heat Q and work W. For a closed system (batch), ΔU + ΔE_k + ΔE_p = Q − W. For an open system at steady state (flow processes), the work needed to push fluid in and out (flow work pV) is combined with U into enthalpy H = U + pV: ΔḢ + ΔĖ_k + ΔĖ_p = Q̇ − Ẇ_s, where Ẇ_s is shaft work. In most chemical-engineering units (heaters, coolers, reactors, columns) kinetic and potential energy changes are negligible, so Q̇ = ΔḢ = Σ(ṁĥ)_out − Σ(ṁĥ)_in.
At steady state nothing in the system changes with time, so accumulation is zero. In an unsteady (transient) process, such as heating a batch tank or filling a vessel, the accumulation term d(mU)/dt remains, and the balance becomes a differential equation, e.g. m c_p dT/dt = Q̇ for a well-stirred tank with a heating coil.
Enthalpy is a state function, so changes are calculated along any convenient path from a reference state: sensible heat ∫c_p dT for temperature changes in one phase, and latent heats (fusion, vaporisation) for phase changes at constant temperature. Heat capacities are given as polynomials c_p = a + bT + cT² + … or as mean values over a range; steam tables give water and steam enthalpies directly.
- Closed: ΔU + ΔE_k + ΔE_p = Q − W.
- Open, steady: ΔḢ + ΔĖ_k + ΔĖ_p = Q̇ − Ẇ_s.
- Most units: Q̇ = ΔḢ.
- Transient tank: m c_p dT/dt = Q̇.
Example: How much heat is needed to turn 100 kg/h of water at 25 °C into saturated steam at 100 °C and 1 atm (c_p = 4.18 kJ/kg·K, λ = 2257 kJ/kg)?
- Sensible heat = 4.18 × (100 − 25) = 313.5 kJ/kg.
- Latent heat = 2257 kJ/kg.
- Total = 2570.5 kJ/kg × 100 kg/h = 257 050 kJ/h.
- = 257 050/3600 = 71.4 kW.
Answer: About 257 MJ/h (71.4 kW); latent heat is 88 % of it.
Example: A stirred tank holds 1000 kg of water at 20 °C and is heated by a 50 kW coil with no losses. How long until it reaches 80 °C?
- Unsteady energy balance: m c_p dT/dt = Q̇.
- dT/dt = 50/(1000 × 4.18) = 0.01196 K/s.
- t = (80 − 20)/0.01196 = 5016 s.
Answer: About 84 minutes.
Heats of formation, reaction and combustion, and reactive balances
The standard heat of formation ΔH°f of a compound is the enthalpy change when 1 mol of it is formed from its elements in their standard states at 25 °C and 1 atm; for elements in their standard state it is zero. The standard heat of combustion ΔH°c is the enthalpy change when 1 mol burns completely in oxygen to specified products (CO₂(g), H₂O(l) for the higher or gross value; H₂O(g) for the lower or net value). Both are tabulated.
Because enthalpy is a state function, Hess’s law lets heats of reaction be found from these tables: ΔH°r = Σν_i ΔH°f,i (products positive, reactants negative), or ΔH°r = −Σν_i ΔH°c,i. Negative ΔH°r means exothermic, positive endothermic. At another temperature T, Kirchhoff’s law gives ΔH_r(T) = ΔH°r + ∫Δc_p dT, with Δc_p = Σν_i c_p,i.
For a reactor energy balance two equivalent references are used. Heat-of-reaction method: reference reactants and products at 25 °C as elements of the reaction, Q̇ = ξΔH°r + Σ(ṅĤ)_out − Σ(ṅĤ)_in with sensible enthalpies from 25 °C. Heat-of-formation method: reference the elements at 25 °C, so each species carries Ĥ = ΔH°f + sensible heat, and Q̇ = Σ(ṅĤ)_out − Σ(ṅĤ)_in automatically includes the reaction. For an adiabatic reactor Q̇ = 0 gives the outlet temperature, e.g. the adiabatic flame temperature for combustion.
- ΔH°r = Σν_i ΔH°f,i = −Σν_i ΔH°c,i.
- Kirchhoff: ΔH_r(T) = ΔH°r + Δc_p(T − 298).
- GCV − NCV = latent heat of the water formed.
- Adiabatic reactor: Q = 0 ⇒ outlet T.
Example: Find ΔH°r for CH₄ + 2O₂ → CO₂ + 2H₂O(g), given ΔH°f: CH₄ −74.85, CO₂ −393.51, H₂O(g) −241.82 kJ/mol.
- Products: −393.51 + 2(−241.82) = −877.15 kJ.
- Reactants: −74.85 + 0 = −74.85 kJ.
- ΔH°r = −877.15 − (−74.85) = −802.30 kJ/mol CH₄.
Answer: −802.3 kJ/mol (the lower heating value of methane).
Example: Find ΔH°f of CO from the heats of combustion of carbon (−393.51 kJ/mol) and CO (−282.98 kJ/mol).
- C + O₂ → CO₂: −393.51. CO + ½O₂ → CO₂: −282.98.
- Subtract: C + ½O₂ → CO: ΔH = −393.51 − (−282.98).
- = −110.53 kJ/mol.
Answer: −110.5 kJ/mol (cannot be measured directly because some CO₂ always forms).
Example: For N₂ + 3H₂ → 2NH₃, ΔH°r = −92.22 kJ and Δc_p ≈ −38.5 J/K (mean). Estimate ΔH_r at 450 °C.
- T − 298 = 723 − 298 = 425 K.
- Δc_p(T − 298) = −38.5 × 425 = −16 360 J = −16.36 kJ.
- ΔH_r = −92.22 − 16.36 = −108.6 kJ.
Answer: About −109 kJ per 2 mol NH₃ at 450 °C.
Closed systems: ΔU + ΔE_k + ΔE_p = Q − W; open steady systems: ΔḢ + ΔĖ_k + ΔĖ_p = Q̇ − Ẇ_s, usually Q̇ = ΔḢ. Unsteady processes keep the accumulation term (m c_p dT/dt = Q̇). Enthalpy changes: sensible ∫c_p dT plus latent heats. ΔH°f, ΔH°c and Hess’s law give ΔH°r; Kirchhoff corrects it to temperature T. Reactor balances use the heat-of-reaction or heat-of-formation reference; Q = 0 gives the adiabatic outlet or flame temperature.
- ΔH°f = 0 for elements in their standard state.
- Gross (higher) heating value has liquid water in the products.
- Exothermic: ΔH_r < 0.
- Steam tables replace c_p and λ for water.
Key formulas
- Q − W_s = ΔH + ΔE_k + ΔE_p
- ΔH = ∫c_p dT + λ
- ΔH°r = Σν_i ΔH°f,i
- ΔH_r(T) = ΔH°r + ∫Δc_p dT
- m c_p dT/dt = Q̇ (unsteady tank)
Practice questions
The heat of formation of O₂(g) at 25 °C is
- −393.5 kJ/mol
- 0
- +241.8 kJ/mol
- undefined
Show the answer
Answer: B. 0 Element in standard state.
For an open steady-flow heater with no work and negligible KE/PE, Q equals
- ΔU
- ΔH
- W
- zero
Show the answer
Answer: B. ΔH Q = ΔH.
Hess’s law follows because enthalpy is
- a path function
- a state function
- always negative
- temperature-independent
Show the answer
Answer: B. a state function Route does not matter.
The difference between gross and net calorific value is the
- sensible heat of flue gas
- latent heat of water formed
- heat of formation of CO₂
- excess air
Show the answer
Answer: B. latent heat of water formed GCV includes condensation.
Kirchhoff’s law gives the variation of heat of reaction with
- pressure
- temperature
- concentration
- catalyst
Show the answer
Answer: B. temperature Through Δc_p.
Theory questions
Derive the steady-state energy balance for an open system and show how it reduces for a heat exchanger and a turbine. (6 marks)
Show the model answer
For a control volume with mass entering and leaving, energy in = energy out at steady state: Σṁ(u + pv + v²/2 + gz)_in + Q̇ = Σṁ(u + pv + v²/2 + gz)_out + Ẇ_s, where pv is flow work. With h = u + pv: Q̇ − Ẇ_s = Σṁ(h + v²/2 + gz)_out − Σṁ(h + v²/2 + gz)_in. Heat exchanger (no work, KE/PE negligible): Q̇ = ΔḢ for each side, and for the whole adiabatic exchanger ṁ_h(h_in − h_out) = ṁ_c(h_out − h_in). Adiabatic turbine: Ẇ_s = ṁ(h_in − h_out).
Define standard heat of formation, heat of reaction and heat of combustion and show how ΔH°r is found from either formation or combustion data. (5 marks)
Show the model answer
ΔH°f: enthalpy change to form 1 mol of a compound from its elements in their standard states at 25 °C, 1 atm. ΔH°r: enthalpy change for the reaction as written, reactants and products at standard conditions. ΔH°c: enthalpy change for complete combustion of 1 mol with O₂ to CO₂, H₂O (and SO₂, N₂) at standard conditions. By Hess’s law (enthalpy a state function), ΔH°r = Σν_i ΔH°f,i (products minus reactants), or ΔH°r = −Σν_i ΔH°c,i (reactants minus products), because burning reactants and products all gives the same combustion products.
Introduction to computer tools
Topics: Use of spreadsheets to solve basic calculations, introduction to flowsheeting methods, computer tools to solve basic problems of chemical engineering.
Spreadsheets, solvers and flowsheeting
Most first calculations in chemical engineering are a set of equations: balances, equilibrium relations and property correlations. A spreadsheet (Excel, LibreOffice Calc, Google Sheets) is ideal for them. Put each input in its own labelled cell, write formulas that refer to cells (not typed numbers), and the whole calculation updates when an input changes. Unit conversions, gas-law and humidity calculations, and property tables become reusable templates.
Linear material balances can be solved directly with matrix functions: put the coefficients in a matrix A and the right-hand sides in b, then x = MMULT(MINVERSE(A), b). Non-linear equations of one variable (bubble point, flame temperature, friction factor from Colebrook) are solved with Goal Seek (set a cell to a target by changing another), and systems of non-linear equations or optimisation problems with Solver. Iterative calculations can also be set out row by row: successive substitution, Newton–Raphson x_(k+1) = x_k − f(x_k)/f′(x_k), or bisection.
Flowsheeting programs (Aspen Plus, Aspen HYSYS, DWSIM, ChemCAD, COCO) solve whole plants. The user draws the flowsheet from library unit models (mixers, splitters, flashes, reactors, columns, exchangers, pumps), picks components and a thermodynamic model (ideal, Peng–Robinson, NRTL…), and specifies feeds and unit conditions. Sequential-modular programs calculate one unit at a time in flow order; when a recycle exists they guess (tear) a stream, go round the loop and update the guess until it stops changing, using successive substitution or Wegstein acceleration. Equation-oriented programs instead solve all the equations of the plant together with Newton’s method. DWSIM and COCO are free; the Project Studio on this site works the same sequential-modular way.
- Inputs in cells; formulas refer to cells.
- Linear systems: MINVERSE and MMULT.
- One non-linear equation: Goal Seek; several: Solver.
- Sequential modular: unit by unit, tear streams for recycle.
- Equation oriented: solve all equations together.
Example: A recycle loop has A → B with 20 % single-pass conversion and 100 mol/h fresh A; unreacted A is recycled. Solve for the recycle by successive substitution, starting from R = 0.
- Tear equation: R_new = 0.8 × (100 + R_old).
- R: 0 → 80 → 144 → 195.2 → 236.2 → 268.9 → …
- Each step closes 20 % of the remaining gap; after 20 iterations R = 395.4; the exact answer is R = 80/0.2 = 400 mol/h.
- Wegstein acceleration uses the slope of R_new vs R_old (here 0.8) to jump: R = (80)/(1 − 0.8) = 400 in one step.
Answer: R = 400 mol/h; plain substitution converges slowly, Wegstein in one step for a linear loop.
Example: Set up the separation balance x + y + z = 100, 0.5x + 0.2y = 30, 0.3x + 0.5y + 0.1z = 28 and solve it as a spreadsheet would.
- From the second equation: y = 150 − 2.5x; from the first: z = 100 − x − y = 1.5x − 50.
- Third: 0.3x + 0.5(150 − 2.5x) + 0.1(1.5x − 50) = 28 ⇒ 70 − 0.8x = 28 ⇒ x = 52.5.
- y = 150 − 131.25 = 18.75; z = 78.75 − 50 = 28.75.
- In a spreadsheet: =MMULT(MINVERSE(A1:C3), D1:D3) entered over three cells gives the same values.
Answer: x = 52.5, y = 18.75, z = 28.75.
Example: Use Newton–Raphson to solve x³ − 2x − 5 = 0 starting from x = 2 (the kind of equation a cubic equation of state gives).
- f(x) = x³ − 2x − 5, f′(x) = 3x² − 2.
- x₁ = 2 − (8 − 4 − 5)/(12 − 2) = 2 + 0.1 = 2.1.
- x₂ = 2.1 − (9.261 − 4.2 − 5)/(13.23 − 2) = 2.1 − 0.061/11.23 = 2.09457.
- x₃ = 2.09455 (converged).
Answer: x = 2.0946; Newton–Raphson doubles the number of correct digits each step.
Spreadsheets make calculations reusable: inputs in cells, formulas by reference. Linear balances by MINVERSE/MMULT or Gaussian elimination; single non-linear equations by Goal Seek, Newton–Raphson or bisection; systems and optimisation by Solver. Flowsheeting software (Aspen Plus/HYSYS, DWSIM, ChemCAD, COCO) builds plants from unit models with a thermodynamic package; sequential-modular solvers tear recycle streams and iterate (successive substitution, Wegstein), equation-oriented solvers solve all equations at once.
- Never type a number into a formula: reference a labelled input cell.
- Check a spreadsheet with a hand-solved case.
- Choose the thermodynamic model carefully in simulators.
- Tear streams are guessed and iterated to convergence.
Key formulas
- x = A⁻¹ b
- x_(k+1) = x_k − f(x_k)/f′(x_k)
- Wegstein: x = (g − s·x)/(1 − s), s = slope of g
- DOF = 0 before solving
Practice questions
In a spreadsheet, a set of linear balances Ax = b is solved with
- VLOOKUP
- MINVERSE and MMULT
- SUMIF
- CONCATENATE
Show the answer
Answer: B. MINVERSE and MMULT x = A⁻¹b.
Goal Seek is used to
- sort data
- solve one equation by changing one cell
- draw charts
- format cells
Show the answer
Answer: B. solve one equation by changing one cell Single-variable solver.
A tear stream is used in
- equation-oriented simulators only
- sequential-modular solution of recycle loops
- spreadsheets only
- P&IDs
Show the answer
Answer: B. sequential-modular solution of recycle loops Iterated guess.
Which of these is a free process simulator?
- Aspen Plus
- DWSIM
- ChemCAD
- HYSYS
Show the answer
Answer: B. DWSIM Open source.
Newton–Raphson converges
- linearly
- quadratically near the root
- never
- only for linear equations
Show the answer
Answer: B. quadratically near the root Digits double each step.
Theory questions
Explain how a spreadsheet can be used to solve material balance problems, giving an example of linear and non-linear cases. (5 marks)
Show the model answer
Linear: write the balances as Ax = b, enter A and b in cells and compute x = MMULT(MINVERSE(A), b) as an array formula; e.g. a three-product separation with total and two component balances. Non-linear: e.g. bubble point of a benzene–toluene liquid; put T in a cell, compute Antoine vapour pressures and Σx_i p_i° − P in another, and use Goal Seek to make it zero by changing T. Systems of non-linear equations (equilibrium conversion, flash) use Solver. Iterations (recycle convergence) can be laid out row by row.
Distinguish between sequential-modular and equation-oriented flowsheeting, and explain how recycle is handled in the former. (5 marks)
Show the model answer
Sequential-modular: each unit is a module that calculates outputs from inputs; units are computed in flow order. Easy to build and debug, but recycle loops need iteration: a stream in the loop is torn (its values guessed), the loop is calculated, the new values are compared with the guess and updated by successive substitution or Wegstein/Broyden acceleration until converged; design specifications add outer loops. Equation-oriented: all model equations of all units are collected and solved simultaneously by Newton-type methods; faster for large, highly recycled or optimisation problems, but needs good initial guesses and is harder to debug. Aspen Plus and DWSIM are mainly sequential modular; equation-oriented options exist in Aspen Plus EO and gPROMS.
Notes, examples and questions were written for this studio; the prescribed books are listed in the studio for reference.
Frequently asked questions
What is the Introduction to Chemical Engineering Studio?
Balances, gases and humidity, step by step. Unit operations and flowsheets, units, gases, Raoult and Dalton, limiting reactant, combustion, humidity, material balances with recycle, bypass and purge, energy balances and spreadsheet solving from the ASTU CHE241304 syllabus.
What can I do in the Introduction to Chemical Engineering Studio?
Unit operations, unit processes and flowsheets; Gases, Raoult and Dalton, limiting reactant and combustion; Humidity and the psychrometric chart; Material and energy balances with recycle, bypass and purge.
Is the Introduction to Chemical Engineering Studio free?
Yes. It is free and runs in your browser with no sign-up.