IITIAN1997 STUDIO

Energy Engineering

Fuels, sun, wind and saving energy.

Open the interactive studio →

Energy scenario, coal and fuels, nuclear, solar PV and thermal, biomass and biogas, wind, hydro, fuel cells and energy audits, following the ASTU alternative energy syllabus.

What is inside

  • Fuels, heating values and combustion air
  • Solar PV, wind, hydro and biogas sizing
  • Nuclear energy and fuel cells
  • Energy conservation and audit with payback

Syllabus: ASTU CHE1816OE21 Energy Engineering (Alternative Energy Resources), semester 6, 2018 scheme (open elective). Official syllabus PDF.

Energy scenario and the energy crisis

Topics: World and Indian energy scenario; per-capita consumption and development; finite fossil reserves; reserve-to-production ratio; environmental impact: CO₂, SOx, NOx, particulates; climate change; energy security; need for alternatives.

Energy use tracks development, and most of it still comes from coal, oil and gas. Reserves are finite: the reserve-to-production ratio R/P (years) tells how long current reserves last at present output. Burning fossil fuel releases CO₂ (about 3.67 kg per kg of carbon), SO₂ and NOx, driving climate change and acid rain. India imports most of its crude oil, so renewables and efficiency also improve energy security.

  • R/P = reserves/annual production (years).
  • 1 kg C → 3.67 kg CO₂.
  • Energy intensity = energy/GDP.
  • India’s 2030 target: 500 GW non-fossil capacity.

Key formulas

  • R/P = reserves/production
  • CO₂ = 44/12 × carbon burned
  • Energy intensity = E/GDP

Practice questions

Burning 1 kg of carbon gives about

  1. 1 kg CO₂
  2. 2.67 kg CO₂
  3. 3.67 kg CO₂
  4. 12 kg CO₂
Show the answer

Answer: C. 3.67 kg CO₂ 44/12.

The R/P ratio is measured in

  1. tonnes
  2. years
  3. kW
  4. ₹
Show the answer

Answer: B. years Reserves divided by annual production.

Acid rain is mainly due to

  1. CO₂
  2. SO₂ and NOx
  3. O₂
  4. argon
Show the answer

Answer: B. SO₂ and NOx Acid oxides.

A renewable source is

  1. coal
  2. natural gas
  3. wind
  4. uranium
Show the answer

Answer: C. wind Replenished naturally.

Theory questions

A country has 300 billion t of coal reserves and mines 1 billion t/year. Find R/P and the CO₂ if the coal is 60 % carbon. (3 marks)

Show the model answer

R/P = 300 years. CO₂ per year = 1 × 10⁹ × 0.6 × 3.67 = 2.2 × 10⁹ t.

Why is there an energy crisis? (4 marks)

Show the model answer

Rising demand, finite and unevenly located fossil reserves, import dependence and price shocks, and the environmental cost of combustion (climate change, pollution) together make the present pattern unsustainable.

Conventional energy resources and fuels

Topics: Coal (proximate and ultimate analysis, ranks), petroleum and natural gas, calorific values (GCV and NCV), Dulong formula; thermal and hydroelectric power plants; combustion calculations and excess air.

Coal is graded by proximate analysis (moisture, volatile matter, ash, fixed carbon) and ultimate analysis (C, H, O, N, S). The Dulong formula estimates GCV = 33 800C + 144 000(H − O/8) + 9 270S kJ/kg (mass fractions). NCV subtracts the latent heat of water formed: NCV = GCV − 9H × 2442. Theoretical air per kg fuel = (2.67C + 8H + S − O)/0.232; excess air ensures complete combustion. Thermal plants follow the Rankine cycle at 33–40 % efficiency; hydro power P = ηρgQH.

  • Ranks: peat → lignite → bituminous → anthracite (rising carbon).
  • Natural gas is mostly methane; LNG is liquefied at −162 °C.
  • Heat rate = 3600/η kJ/kWh.
  • Hydro: P = ηρgQH.

Key formulas

  • GCV (Dulong) = 33 800C + 144 000(H − O/8) + 9 270S kJ/kg
  • NCV = GCV − 9H × 2442 kJ/kg
  • A_th = (2.67C + 8H + S − O)/0.232 kg air/kg fuel
  • P_hydro = η ρ g Q H

Practice questions

The highest-rank coal is

  1. peat
  2. lignite
  3. bituminous
  4. anthracite
Show the answer

Answer: D. anthracite Most carbon.

NCV is less than GCV because of

  1. ash
  2. latent heat of water vapour
  3. nitrogen
  4. excess air
Show the answer

Answer: B. latent heat of water vapour Water leaves as vapour.

A hydro plant with Q = 10 m³/s, H = 100 m, η = 0.9 gives about

  1. 8.8 MW
  2. 88 MW
  3. 0.88 MW
  4. 880 kW
Show the answer

Answer: A. 8.8 MW 0.9 × 1000 × 9.81 × 10 × 100.

Theoretical oxygen for 1 kg carbon is

  1. 1 kg
  2. 2.67 kg
  3. 8 kg
  4. 12 kg
Show the answer

Answer: B. 2.67 kg 32/12.

Theory questions

A coal has C 0.75, H 0.05, O 0.08, S 0.01. Find GCV, NCV and theoretical air. (5 marks)

Show the model answer

GCV = 33 800 × 0.75 + 144 000 × (0.05 − 0.01) + 9 270 × 0.01 = 25 350 + 5 760 + 93 = 31 203 kJ/kg. NCV = 31 203 − 9 × 0.05 × 2442 = 30 104 kJ/kg. Air = (2.0 + 0.4 + 0.01 − 0.08)/0.232 = 10.04 kg/kg.

Differentiate proximate and ultimate analysis of coal. (3 marks)

Show the model answer

Proximate: moisture, volatile matter, ash and fixed carbon by simple heating tests; used for trade and furnace choice. Ultimate: elemental C, H, N, S, O; used for combustion calculations and heating value.

Nuclear energy

Topics: Fission and fusion; binding energy; chain reaction and critical mass; reactor components: fuel, moderator, coolant, control rods, shielding; reactor types: PWR, BWR, PHWR, fast breeder; India’s three-stage programme; waste and safety.

Fission of U-235 releases about 200 MeV per nucleus, so 1 g of U-235 fully fissioned gives about 8.2 × 10¹⁰ J (≈ 0.95 MWd). The mass defect follows E = Δm c². A reactor sustains a controlled chain reaction (k = 1) using a moderator to slow neutrons, control rods (boron, cadmium) to absorb them and a coolant to carry heat to a steam cycle. India’s programme runs PHWRs on natural uranium, fast breeders on plutonium, then thorium reactors.

  • 1 u = 931.5 MeV.
  • Moderators: heavy water, light water, graphite.
  • k_eff < 1 subcritical, = 1 critical, > 1 supercritical.
  • Spent fuel is stored and reprocessed; high-level waste needs long-term isolation.

Key formulas

  • E = Δm c²
  • Energy per fission ≈ 200 MeV
  • Fissions per second = P/(200 × 1.602 × 10⁻¹³ J)

Practice questions

Energy per fission of U-235 is about

  1. 2 MeV
  2. 200 MeV
  3. 2 GeV
  4. 20 keV
Show the answer

Answer: B. 200 MeV Typical value.

Control rods are made of

  1. graphite
  2. boron or cadmium
  3. water
  4. uranium
Show the answer

Answer: B. boron or cadmium Neutron absorbers.

India’s PHWRs use

  1. enriched U and light water
  2. natural U and heavy water
  3. thorium only
  4. plutonium only
Show the answer

Answer: B. natural U and heavy water Stage one.

A moderator

  1. absorbs neutrons
  2. slows neutrons
  3. speeds neutrons
  4. stops fission
Show the answer

Answer: B. slows neutrons Thermal neutrons fission U-235 best.

Theory questions

How many fissions per second produce 1000 MW of thermal power? (3 marks)

Show the model answer

200 MeV = 3.2 × 10⁻¹¹ J, so 10⁹/3.2 × 10⁻¹¹ ≈ 3.1 × 10¹⁹ fissions/s, about 1.05 kg of U-235 per day.

Explain the components of a nuclear reactor. (4 marks)

Show the model answer

Fuel (U-235/Pu), moderator (slows neutrons), control rods (regulate k), coolant (removes heat), reflector, pressure vessel, biological shielding and containment.

Solar energy

Topics: Solar radiation and measurement; solar thermal collectors and applications; photovoltaic cells: working, I–V curve, fill factor, efficiency; PV system sizing; solar ponds and power towers.

A PV cell is a p–n junction: photons create electron–hole pairs that the junction field separates. The I–V curve gives short-circuit current I_sc, open-circuit voltage V_oc and the maximum power point; fill factor FF = P_max/(V_oc I_sc). Efficiency η = P_max/(G A). Energy from a PV array per day ≈ P_rated × peak sun hours × performance ratio (0.75–0.8). Solar thermal collectors heat fluids; power towers and troughs make steam.

  • Standard test conditions: 1000 W/m², 25 °C, AM 1.5.
  • Silicon cells: 18–23 %; panels lose ~0.4 %/°C.
  • Peak sun hours in India: 4.5–6 h/day.
  • Battery sizing: Ah = daily load × days of autonomy/(V × DoD).

Key formulas

  • FF = P_max/(V_oc I_sc)
  • η = P_max/(G A)
  • E_day = P_rated × PSH × PR
  • Battery Ah = E × days/(V × DoD)

Practice questions

Standard irradiance for PV rating is

  1. 100 W/m²
  2. 1000 W/m²
  3. 1361 W/m²
  4. 500 W/m²
Show the answer

Answer: B. 1000 W/m² STC.

Fill factor is

  1. V_oc/I_sc
  2. P_max/(V_oc I_sc)
  3. I_sc/V_oc
  4. η × A
Show the answer

Answer: B. P_max/(V_oc I_sc) Squareness of the I–V curve.

PV output with rising cell temperature

  1. rises
  2. falls
  3. unchanged
  4. doubles
Show the answer

Answer: B. falls V_oc falls.

A 1 kW array with 5 peak sun hours and PR 0.8 gives per day

  1. 4 kWh
  2. 5 kWh
  3. 8 kWh
  4. 1 kWh
Show the answer

Answer: A. 4 kWh 1 × 5 × 0.8.

Theory questions

A cell of 0.0244 m² (156 mm square) has V_oc = 0.64 V, I_sc = 9 A, FF = 0.78 at 1000 W/m². Find P_max and η. (3 marks)

Show the model answer

P_max = 0.78 × 0.64 × 9 = 4.49 W; incident power = 1000 × 0.0244 = 24.4 W; η = 4.49/24.4 = 18.4 %.

Explain the working of a solar PV cell. (4 marks)

Show the model answer

Photons with energy above the band gap create electron–hole pairs; the built-in field of the p–n junction drives electrons to the n side and holes to the p side, producing a voltage; connecting a load lets current flow. Losses: reflection, sub-band-gap photons, heat, recombination, resistance.

Biomass energy

Topics: Biomass resources; conversion routes: combustion, gasification, pyrolysis, anaerobic digestion (biogas), fermentation (ethanol), transesterification (biodiesel); biogas plant types (KVIC floating drum, Deenbandhu fixed dome); producer gas.

Biomass stores solar energy as carbohydrates. Thermochemical routes (combustion, gasification to producer gas CO + H₂, pyrolysis to bio-oil and char) suit dry biomass; biochemical routes suit wet wastes. Anaerobic digestion yields biogas (55–65 % CH₄, rest CO₂), about 0.04 m³ per kg of fresh cattle dung, with a heating value near 20 MJ/m³. Ethanol comes from fermenting sugars; biodiesel from transesterifying oils with methanol.

  • Digestion stages: hydrolysis, acidogenesis, acetogenesis, methanogenesis.
  • Best at 30–40 °C (mesophilic), pH 6.8–7.5, C/N ≈ 25–30.
  • Hydraulic retention time 30–50 days for cattle dung.
  • Biomass is near carbon-neutral if regrown.

Key formulas

  • Biogas ≈ 0.04 m³ per kg fresh dung
  • Digester volume = daily slurry × HRT
  • Energy = V_gas × 20 MJ/m³

Practice questions

The main fuel gas in biogas is

  1. CO
  2. CH₄
  3. H₂
  4. C₂H₂
Show the answer

Answer: B. CH₄ 55–65 %.

Producer gas is made by

  1. digestion
  2. gasification
  3. fermentation
  4. electrolysis
Show the answer

Answer: B. gasification Partial oxidation.

Biodiesel is made by

  1. transesterification
  2. pyrolysis
  3. cracking
  4. distillation
Show the answer

Answer: A. transesterification Oil + methanol.

Methane-forming bacteria work best at a pH near

  1. 3
  2. 7
  3. 11
  4. 1
Show the answer

Answer: B. 7 Neutral.

Theory questions

A farm has 20 cattle giving 10 kg dung each per day. Estimate biogas, energy and digester volume (slurry 1:1 with water, HRT 40 d). (4 marks)

Show the model answer

Dung 200 kg/d ⇒ gas 8 m³/d ⇒ 160 MJ/d. Slurry 400 kg ≈ 0.4 m³/d × 40 = 16 m³ digester.

Compare floating-drum and fixed-dome biogas plants. (3 marks)

Show the model answer

Floating drum (KVIC): steel gas holder rises with gas, constant pressure, costlier and needs painting. Fixed dome (Deenbandhu): masonry, cheaper, longer life, gas pressure varies.

Wind, geothermal, tidal and hydro

Topics: Wind power: power in the wind, Betz limit, turbine types, power curve; geothermal: hydrothermal sources, dry and flash steam, binary plants; tidal and wave energy; small hydro.

Wind power through a rotor of area A is P = ½ρAV³; no turbine can capture more than the Betz limit 16/27 = 59.3 %; real rotors reach C_p ≈ 0.40–0.48. Because power varies with V³, siting is critical. Annual energy uses the capacity factor: E = P_rated × 8760 × CF. Geothermal plants use hot water or steam from the earth (flash or binary cycle). Tidal plants trap water behind a barrage: energy per tide ≈ ½ρgAR².

  • P ∝ V³ and ∝ D².
  • Horizontal-axis turbines dominate; vertical-axis (Darrieus, Savonius) need no yaw.
  • Cut-in, rated and cut-out speeds define the power curve.
  • Tidal range R is key: energy ∝ R².

Key formulas

  • P = ½ ρ A V³ C_p
  • C_p,max = 16/27
  • E_year = P_rated × 8760 × CF
  • E_tide = ½ ρ g A R²

Practice questions

The Betz limit is

  1. 50 %
  2. 59.3 %
  3. 80 %
  4. 100 %
Show the answer

Answer: B. 59.3 % 16/27.

Doubling wind speed multiplies power by

  1. 2
  2. 4
  3. 8
  4. 16
Show the answer

Answer: C. 8 V³.

A Savonius rotor is a

  1. horizontal-axis turbine
  2. vertical-axis turbine
  3. tidal barrage
  4. geothermal well
Show the answer

Answer: B. vertical-axis turbine Drag type.

Tidal energy per cycle varies with range R as

  1. R
  2. R²
  3. R³
  4. √R
Show the answer

Answer: B. R² ½ρgAR².

Theory questions

A turbine of 80 m rotor diameter at 10 m/s (ρ = 1.225, C_p = 0.42). Find power. (3 marks)

Show the model answer

A = π × 40² = 5027 m². P = 0.5 × 1.225 × 5027 × 1000 × 0.42 ≈ 1.29 MW.

Explain a geothermal binary-cycle plant. (3 marks)

Show the model answer

Moderate-temperature brine heats a low-boiling working fluid (isobutane) in an exchanger; its vapour drives a turbine; the brine is reinjected, so no steam is vented.

Fuel cells and hydrogen

Topics: Principle of fuel cells; types: PEMFC, AFC, PAFC, MCFC, SOFC; efficiency; hydrogen production (steam reforming, electrolysis), storage and safety.

A fuel cell converts chemical energy directly to electricity: at the anode H₂ → 2H⁺ + 2e⁻, at the cathode ½O₂ + 2H⁺ + 2e⁻ → H₂O. Reversible voltage E° = −ΔG/(nF) = 1.23 V at 25 °C; ideal efficiency ΔG/ΔH = 237.1/285.8 = 83 %. Real cells run at 0.6–0.8 V. Types differ in electrolyte and temperature (PEM ≈ 80 °C, SOFC ≈ 800 °C). Hydrogen comes mainly from steam reforming of natural gas, or from electrolysis using renewable power (green hydrogen).

  • Not limited by the Carnot efficiency.
  • Electrolysis needs ≥ 39.4 kWh per kg H₂ (HHV); real 50–55 kWh/kg.
  • Hydrogen: wide flammability limits (4–75 %), low ignition energy.
  • PEM catalysts use platinum.

Key formulas

  • E° = −ΔG/(nF) = 1.23 V
  • η_ideal = ΔG/ΔH = 0.83
  • Current I = n F ṅ_H₂
  • P = V I

Practice questions

Theoretical voltage of an H₂–O₂ cell at 25 °C is

  1. 0.6 V
  2. 1.23 V
  3. 2 V
  4. 0.83 V
Show the answer

Answer: B. 1.23 V −ΔG/2F.

A SOFC operates near

  1. 80 °C
  2. 200 °C
  3. 800 °C
  4. 25 °C
Show the answer

Answer: C. 800 °C Ceramic electrolyte.

Most hydrogen today is made by

  1. electrolysis
  2. steam reforming of methane
  3. photosynthesis
  4. coal burning
Show the answer

Answer: B. steam reforming of methane SMR.

Fuel cell efficiency is not limited by

  1. Faraday’s law
  2. the Carnot efficiency
  3. Gibbs energy
  4. resistance
Show the answer

Answer: B. the Carnot efficiency Direct conversion.

Theory questions

A PEM stack draws 100 A at 0.7 V per cell for 50 cells. Find power and hydrogen use. (4 marks)

Show the model answer

Power = 50 × 0.7 × 100 = 3.5 kW. H₂ per cell = I/(2F) = 100/192 970 = 5.18 × 10⁻⁴ mol/s; for 50 cells 0.0259 mol/s = 0.0522 g/s ≈ 188 g/h.

Explain the working of a hydrogen–oxygen fuel cell. (4 marks)

Show the model answer

H₂ at the anode splits into protons and electrons on the catalyst; protons cross the electrolyte, electrons go through the external circuit doing work; at the cathode they combine with O₂ to form water. Output is DC, heat and water.

Energy conservation and energy audit

Topics: Energy conservation in industry; Energy Conservation Act 2001; BEE; preliminary and detailed energy audit; energy-saving opportunities in boilers, furnaces, steam, motors, pumps, fans, compressed air, lighting; simple payback and ROI; waste-heat recovery.

An energy audit measures where energy goes, then lists savings with their cost and payback. A preliminary audit uses existing data for quick wins; a detailed audit measures each unit. Typical savings: excess-air control and economisers in boilers, steam-trap repair, insulation, condensate recovery, variable-speed drives on pumps and fans (power ∝ speed³ by affinity laws), compressed-air leak repair and LED lighting. Simple payback = investment/annual savings.

  • BEE (Bureau of Energy Efficiency) runs PAT and star labels.
  • Affinity laws: Q ∝ N, H ∝ N², P ∝ N³.
  • Each 10 % excess air reduction ≈ 1 % fuel saving (rule of thumb).
  • Specific energy consumption = energy/unit product.

Key formulas

  • Payback = investment/annual savings
  • P₂ = P₁(N₂/N₁)³
  • Savings = ΔkW × hours × tariff
  • SEC = energy/production

Practice questions

Reducing a fan speed by 20 % reduces power to about

  1. 80 %
  2. 64 %
  3. 51 %
  4. 20 %
Show the answer

Answer: C. 51 % 0.8³.

The statutory body for energy efficiency in India is

  1. BEE
  2. BIS
  3. CPCB
  4. NTPC
Show the answer

Answer: A. BEE Bureau of Energy Efficiency.

Simple payback equals

  1. savings/investment
  2. investment/annual savings
  3. investment × savings
  4. NPV
Show the answer

Answer: B. investment/annual savings Years.

A preliminary audit

  1. needs detailed instruments
  2. uses existing data for quick wins
  3. lasts years
  4. is mandatory every day
Show the answer

Answer: B. uses existing data for quick wins Walk-through.

Theory questions

A 75 kW pump runs 8000 h/year; a VFD cuts its speed to 80 %. Savings at ₹8/kWh and payback on a ₹6 lakh VFD? (4 marks)

Show the model answer

New power = 75 × 0.512 = 38.4 kW; saving 36.6 kW × 8000 = 292 800 kWh = ₹23.4 lakh/year; payback ≈ 0.26 year (3 months). (Real savings are smaller where static head is large.)

What is an energy audit? Describe its types. (4 marks)

Show the model answer

A systematic study of energy use to find savings. Preliminary: walk-through using bills and data, quick no-cost/low-cost measures. Detailed: instrumented measurements, mass and energy balances of major units, investment-grade proposals with payback.

Notes, examples and questions were written for this studio; the prescribed books are listed in the studio for reference.

Frequently asked questions

What is the Energy Engineering Studio?

Fuels, sun, wind and saving energy. Energy scenario, coal and fuels, nuclear, solar PV and thermal, biomass and biogas, wind, hydro, fuel cells and energy audits, following the ASTU alternative energy syllabus.

What can I do in the Energy Engineering Studio?

Fuels, heating values and combustion air; Solar PV, wind, hydro and biogas sizing; Nuclear energy and fuel cells; Energy conservation and audit with payback.

Is the Energy Engineering Studio free?

Yes. It is free and runs in your browser with no sign-up.

Open the interactive studio →